Stena Multi-Layer Flow Modulator for Peripheral

Flow-diverting stent for peripheral arteries, redistributing laminar flow away from diseased vessel segments, aiding aneurysm or side-branch preservation.

Stena Multi-Layer Flow Modulator

  • Material: Constructed from biocompatible and resilient materials for long-term stability.
  • Design: Intricate multilayer design to modulate blood flow and enhance hemodynamic stability.
  • Diameter Range: Available in various sizes to cater to different peripheral vascular structures.

Innovate Peripheral Interventions with Advanced Flow Modulation

  • Flexibility: High flexibility to conform to the natural anatomy of peripheral vessels.
  • Radial Strength: Provides sufficient support to maintain vessel patency without
    compromising flexibility.

The Gold Standard in Hemodynamic Stability and Vascular Protection

  • Porosity: Designed with optimal porosity to balance flow modulation and prevent
    end-organ ischemia.
  • Compatibility: Compatible with various guide catheters and delivery systems
    for ease of use.
  • Its unique multilayer design is a hallmark of innovation, providing unmatched flow modulation and hemodynamic stability.
     
  • This design ensures that blood flow is optimally distributed, reducing the risk of complications and enhancing the overall success of the intervention.

  • The device’s construction from biocompatible materials ensures its longevity and reliability, while the range of available sizes guarantees a perfect fit for a variety of peripheral vascular structures. 

  • The combination of flexibility and radial strength ensures that the device adapts to the patient’s anatomy while maintaining vessel patency and integrity.

  • With its optimal porosity and compatibility with various catheters and delivery systems, the Stena Multilayer Flow Modulator stands out as a leader in peripheral vascular care, delivering both innovation and reliability in every procedure.

Endothelialization and integration, as the uncovered device allows endothelial tissue to be generated on the braided structure

General Product Specifications

Specification Detail / Value
Product Name Stena Multi-Layer Flow Modulator (Peripheral)
Intended Use Endovascular treatment of peripheral aneurysms (e.g., popliteal, iliac) and flow modulation in complex peripheral lesions
Design Multi-layer, self-expanding stent with braided nitinol mesh structure
Deployment Mechanism Sheath-based retraction for self-expansion; no balloon inflation needed
Material Medical-grade Nitinol (Nickel-Titanium) in layered/braided configuration
Delivery System Over-the-wire (OTW), typically 5–8F introducer sheath (depending on stent diameter)
Radial Force Moderate to high, ensuring stable vessel wall contact
Radiopaque Markers Proximal and distal marker bands for fluoroscopic placement
MR Compatibility MR Conditional (verify local labeling)
Sterility Sterile (EO)
Single Use Yes
Shelf Life ~3–5 years if stored at 15–25 °C in sealed packaging
Clinical Indications Peripheral aneurysms (iliac, popliteal), flow diversion in side branches or collateral vessels
Contraindications Extremely calcified or tortuous peripheral arteries precluding safe deployment; nickel allergy; insufficient landing zone

Peripheral Flow Modulator

Diameter (mm) Length (mm) Sheath Rec. (F) Product Code Notes
5 40 ~5F STM-P-5x40 Very small diameter for popliteal or tibial aneurysms
5 60 ~5F STM-P-5x60
6 40 ~6F STM-P-6x40 Medium diameter, short coverage
6 60 ~6F STM-P-6x60
6 80 ~6F STM-P-6x80
7 40 ~6F STM-P-7x40 Slightly larger diameter for moderate vessel
7 80 ~6F STM-P-7x80
7 100 ~7F STM-P-7x100 Extended coverage for segmental aneurysms
8 60 ~7F STM-P-8x60 Common size for iliac or superficial femoral
8 100 ~7F STM-P-8x100
8 120 ~8F STM-P-8x120 Longer coverage for multi-lobed aneurysms
9 80 ~8F STM-P-9x80 Larger diameter for proximal popliteal or iliac
9 120 ~8F STM-P-9x120
9 150 ~8F STM-P-9x150 Max length for extended lesions
10 80 ~8F STM-P-10x80 High diameter for large peripheral arteries
10 120 ~8F STM-P-10x120
10 150 ~8F or 9F STM-P-10x150
12 80 ~9F STM-P-12x80 Very large diameter for wide aneurysms
12 120 ~9F STM-P-12x120
12 150 ~9F STM-P-12x150 Extended coverage for extensive aneurysmal segments