Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration
A التناوب system featuring a leaf tip design for الميكانيكية تجزئة الجلطة زائد قوي قدرات الشفط في حالات الانسداد الوريدي أو الشرياني العميق.
إن Mantis Rotational Thrombectomy System is an advanced catheter-based device engineered to disrupt and remove thrombus from peripheral and/or central vasculature. Utilizing a leaf tip design and a Nitinol shaft reinforced with PA/PEBAX polymers, the Mantis system delivers a high-torque, low-profile solution for physicians aiming to restore flow in acute, subacute, or chronic thrombotic occlusions.
Leaf Tip Design
- The proprietary leaf tip shape allows precise clot engagement and fragmentation, enhancing device efficiency in complex or large-burden thrombotic lesions.
- Distal Infusion Zone: Positioned between the leaf tip and the catheter’s distal end, enabling targeted delivery of thrombolytic agents or contrast media when required.
Nitinol Shaft with PA/PEBAX
- High Torque Response: Nitinol’s superelastic properties provide excellent pushability, kink resistance, and precise rotational control, even in tortuous anatomies.
- Composite Construction: The PA/PEBAX polymer layers offer a smooth lumen and robust structural support, minimizing friction while improving durability.
Radiopaque Shaft Markings
- Nitinol Wire Visibility: Clear radiopacity from the distal tip to the proximal shaft allows real-time, precise imaging under fluoroscopy.
- Facilitates accurate positioning and ensures confident navigation through complex vascular pathways.
Flexible Catheter Profiles
- Available in 5.0F and 6.0F to accommodate varying vessel diameters and flow requirements.
- Active Zone: Ranges from 5 mm to 60 mm, enabling versatile clot engagement depths and optimal coverage in different occlusion lengths.
Multiple Catheter Lengths
90 cm, 110 cm, and 135 cm options provide adaptability for diverse procedural approaches, from short femoral access to more extended radial or brachial routes.
مواصفات المنتج
المواصفات | التفاصيل / القيمة |
اسم المنتج | Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration |
الاستخدام المقصود | Mechanical disruption and aspiration of thrombi or emboli in peripheral and/or venous systems |
تصميم القسطرة | Rotational wire with a leaf-shaped tip, integrated aspiration lumen for clot removal |
المواد | Stainless steel or nitinol drive shaft, flexible polymer outer sheath |
Rotational Speed Range | ~40k–80k rpm (check final specs) |
Aspiration Mechanism | Over-the-wire suction or integrated vacuum line |
Catheter Outer Diameter | ~5–7F, depending on model and tip size |
طول العمل | ~80–120 cm (varies by product code) |
القدرة الإشعاعية | Distal marker near leaf tip for precise positioning under fluoroscopy |
العقم | معقم، للاستخدام مرة واحدة |
مدة الصلاحية | ~2–3 years at 15–25 °C |
المؤشرات السريرية | Acute or subacute thrombotic occlusions in peripheral arteries/veins, possibly deep venous thrombosis (DVT) |
موانع الاستعمال | Extremely tortuous vessels, heavily calcified lesions, or known intolerance to device materials |
مصفوفة الترتيب والحجم
القطر الخارجي (F) | طول العمل (سم) | Leaf Tip Diameter (mm) | رمز المنتج | الملاحظات |
5F | 80 | 5 | MNT-LF-5F-80-5 | Smaller tip for distal or smaller vessels |
5F | 100 | 5 | MNT-LF-5F-100-5 | Longer shaft, same leaf diameter |
6F | 80 | 6 | MNT-LF-6F-80-6 | Common size for peripheral artery usage |
6F | 120 | 6 | MNT-LF-6F-120-6 | Extended length for deeper or proximal segments |
7F | 100 | 7 | MNT-LF-7F-100-7 | Larger leaf tip for heavier thrombus loads |
7F | 120 | 7 | MNT-LF-7F-120-7 | Max length and larger tip for extensive clot burden |
منتجات ذات صلة
-
Atlas Venous Stent
قراءة المزيدA specialized implant system made of biocompatible metal alloys, designed to treat venous obstructions by maintaining vessel patency, improving blood flow, and alleviating symptoms of chronic venous insufficiency.
-
نظام استئصال الدوالي الوريدية بالترددات الراديوية ThermoBLOCK
قراءة المزيدA radiofrequency ablation platform for incompetent superficial veins, offering thermal closure of saphenous or perforating veins to relieve varicose symptoms.
-
قسطرة انحلال الخثرة ViperRA ULTRA
قراءة المزيدأن فائق قسطرة التسريب المخصصة لـ مباشر توصيل الجلطات، ويضم متعدد الفتحات تصميم لتوزيع الأدوية بشكل موحد عبر قطاعات الجلطة الكبيرة.
-
نظام تحليل الخثرة Inca Trellis Trellis
قراءة المزيدA القسطرة التوصيل حال للجلطات وكلاء بينما الفلتر تمنع الحماية من الانصمام القاصي، مما يضمن انحلالًا دوائيًا أكثر أمانًا للجلطات.