Stena Multi-Layer Flow Modulator
- Material: Constructed from biocompatible and resilient materials for long-term stability.
- Design: Intricate multilayer design to modulate blood flow and enhance hemodynamic stability.
- Diameter Range: Available in various sizes to cater to different peripheral vascular structures.
Innovate Peripheral Interventions with Advanced Flow Modulation
- Flexibility: High flexibility to conform to the natural anatomy of peripheral vessels.Radial Strength: Provides sufficient support to maintain vessel patency withoutcompromising flexibility.

The Gold Standard in Hemodynamic Stability and Vascular Protection
- Porosity: Designed with optimal porosity to balance flow modulation and preventend-organ ischemia.Compatibility: Compatible with various guide catheters and delivery systemsfor ease of use.
- Its unique multilayer design is a hallmark of innovation, providing unmatched flow modulation and hemodynamic stability.
- This design ensures that blood flow is optimally distributed, reducing the risk of complications and enhancing the overall success of the intervention.
- The device’s construction from biocompatible materials ensures its longevity and reliability, while the range of available sizes guarantees a perfect fit for a variety of peripheral vascular structures.
- The combination of flexibility and radial strength ensures that the device adapts to the patient’s anatomy while maintaining vessel patency and integrity.
- With its optimal porosity and compatibility with various catheters and delivery systems, the Stena Multilayer Flow Modulator stands out as a leader in peripheral vascular care, delivering both innovation and reliability in every procedure.

Endothelialization and integration, as the uncovered device allows endothelial tissue to be generated on the braided structure
일반 제품 사양
사양 | 세부 정보 / 값 |
제품 이름 | Stena Multi-Layer Flow Modulator (Peripheral) |
사용 목적 | Endovascular treatment of peripheral aneurysms (e.g., popliteal, iliac) and flow modulation in complex peripheral lesions |
디자인 | Multi-layer, self-expanding stent with braided nitinol mesh structure |
배포 메커니즘 | Sheath-based retraction for self-expansion; no balloon inflation needed |
재료 | Medical-grade Nitinol (Nickel-Titanium) in layered/braided configuration |
배달 시스템 | Over-the-wire (OTW), typically 5–8F introducer sheath (depending on stent diameter) |
방사형 힘 | Moderate to high, ensuring stable vessel wall contact |
불투명 마커 | Proximal and distal marker bands for fluoroscopic placement |
MR 호환성 | MR Conditional (verify local labeling) |
무균 | Sterile (EO) |
1회 사용 | 예 |
유통 기한 | ~3–5 years if stored at 15–25 °C in sealed packaging |
임상 적응증 | Peripheral aneurysms (iliac, popliteal), flow diversion in side branches or collateral vessels |
금기 사항 | Extremely calcified or tortuous peripheral arteries precluding safe deployment; nickel allergy; insufficient landing zone |
Peripheral Flow Modulator
지름(mm) | 길이(mm) | 시스 레코드(F) | 제품 코드 | 참고 |
5 | 40 | ~5F | STM-P-5x40 | Very small diameter for popliteal or tibial aneurysms |
5 | 60 | ~5F | STM-P-5x60 | |
6 | 40 | ~6F | STM-P-6x40 | Medium diameter, short coverage |
6 | 60 | ~6F | STM-P-6x60 | |
6 | 80 | ~6F | STM-P-6x80 | |
7 | 40 | ~6F | STM-P-7x40 | Slightly larger diameter for moderate vessel |
7 | 80 | ~6F | STM-P-7x80 | |
7 | 100 | ~7F | STM-P-7x100 | Extended coverage for segmental aneurysms |
8 | 60 | ~7F | STM-P-8x60 | Common size for iliac or superficial femoral |
8 | 100 | ~7F | STM-P-8x100 | |
8 | 120 | ~8F | STM-P-8x120 | Longer coverage for multi-lobed aneurysms |
9 | 80 | ~8F | STM-P-9x80 | Larger diameter for proximal popliteal or iliac |
9 | 120 | ~8F | STM-P-9x120 | |
9 | 150 | ~8F | STM-P-9x150 | Max length for extended lesions |
10 | 80 | ~8F | STM-P-10x80 | High diameter for large peripheral arteries |
10 | 120 | ~8F | STM-P-10x120 | |
10 | 150 | ~8F or 9F | STM-P-10x150 | |
12 | 80 | ~9F | STM-P-12x80 | Very large diameter for wide aneurysms |
12 | 120 | ~9F | STM-P-12x120 | |
12 | 150 | ~9F | STM-P-12x150 | Extended coverage for extensive aneurysmal segments |
연관 상품
-
ATLAS 약물 용출 관상동맥 스텐트 시스템 코발트 크롬
더 보기A 코발트-크롬 관상동맥 스텐트 시술 내구성 있는 방사형 강도 그리고 뛰어난 추적성에 적합 복합 또는 석회화 관상동맥 병변을 최소화하면서 반동을 최소화할 수 있습니다.
-
Extender PTCA 풍선 카테터
더 보기A 표준 고압 관상동맥 풍선 설계 대상 병변 박리 또는 독립형 혈관 성형술를 사용하여 정확한 인플레이션 프로파일과 감소된 교차 프로파일을 제공합니다.
-
AngioTEN 폐쇄 장치
더 보기A 경피적 혈관 폐쇄 시스템 동맥 또는 정맥 사이트에 액세스하여 보안 카테터 삽입 또는 중재 시술 후 지혈.
-
Dolphin PRO 로우 프로파일 횡단 지원 카테터
더 보기A 로우 프로파일 향상된 교차 카테터 추진력 그리고 추적 가능성설계 대상 tight 또는 석회화 관상동맥 또는 말초동맥의 병변.
















































































연락처 및 지원
어떻게 도와드릴까요?
시작하기 전에 자신을 가장 잘 설명할 수 있는 단어는 무엇인가요?
연락처 및 지원
의료 전문가
온라인 문의 양식
일반적인 질문이나 제품 관련 질문은 빠른 온라인 양식을 작성해 주세요. 추적을 위한 확인 및 참조 번호를 받으실 수 있습니다.
제품 문의
임상 및 연구 지원
트레이닝 및 교육
기술 지원
연락처 및 지원
환자 및 간병인
온라인 문의 양식
일반적인 질문이나 제품 관련 질문은 빠른 온라인 양식을 작성해 주세요. 추적을 위한 확인 및 참조 번호를 받으실 수 있습니다.
제품 사용 및 안전
주문 및 결제
지원 및 사후 관리
연락처 및 지원
공급업체 및 유통업체
온라인 문의 양식
일반적인 질문이나 제품 관련 질문은 빠른 온라인 양식을 작성해 주세요. 추적을 위한 확인 및 참조 번호를 받으실 수 있습니다.
파트너십 및 계약
물류 및 배송
규정 준수 및 문서화
연락처 및 지원
공급업체 및 유통업체
온라인 문의 양식
일반적인 질문이나 제품 관련 질문은 빠른 온라인 양식을 작성해 주세요. 추적을 위한 확인 및 참조 번호를 받으실 수 있습니다.
보도 자료 및 뉴스
인터뷰 및 성명서
이벤트 및 컨퍼런스
연락처 및 지원
기타 / 일반 문의
온라인 문의 양식
일반적인 질문이나 제품 관련 질문은 빠른 온라인 양식을 작성해 주세요. 추적을 위한 확인 및 참조 번호를 받으실 수 있습니다.
일반 정보
피드백 및 제안
본사 지원 라인
- 원 월드 트레이드 센터, 285 풀턴 스트리트. 뉴욕, NY 10007, 미국
- globalsales@invamed.com
- +1 (347) 535-0630