Stent venoso Atlas
Um sistema de implante especializado feito de ligas metálicas biocompatíveis, concebido para tratar obstruções venosas, mantendo a permeabilidade dos vasos, melhorando o fluxo sanguíneo e aliviando os sintomas da insuficiência venosa crónica.
O Atlas™ Venous Stent, introduced by Invamed-a fabricante mundial de dispositivos médicos—is meticulously crafted for venous outflow restoration and chronic venous insufficiency management. Leveraging a auto-expansão nitinol design, Atlas™ offers strong radial force, adaptive conformability, and minimal recoil, supporting duradouro patency in challenging venous anatomies.
Self-Expanding Nitinol Framework
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
High Conformability
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Minimal Recoil & Migration
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Optimized for Venous Hemodynamics
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Ampla utilidade clínica
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Contra-indicações
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Technical Specifications
Especificação | Detalhe / Valor |
Nome do produto | Atlas™ Venous Stent |
Stent Material | Nitinol (nickel-titanium) self-expanding alloy |
Mecanismo de implantação | Over-the-wire via introducer sheath (typically 6F–9F, model-specific) |
Força radial | Moderate to high, designed to resist extrinsic compression |
Faixa de diâmetro do stent | ~10–20 mm nominal (expanded), ensuring coverage of varied venous lumen sizes |
Stent Length Range | ~40–120 mm, accommodating short or long-segment lesions |
Marcadores radiopacos | Proximal and distal markers for fluoroscopic visualization |
Esterilidade | Sterile, single use |
Prazo de validade | ~3–5 years if stored at 15–25 °C |
Indicações clínicas | Iliofemoral venous stenosis, post-thrombotic syndrome, extrinsic compression (May-Thurner), chronic venous insufficiency |
Size & Ordering Matrix
Stent Diameter (mm) | Stent Length (mm) | Sheath Compatibility (F) | Código do produto | Notas |
10 | 40 | 6F | AVS-10x40-6F | Smaller diameter for narrower veins or moderate lesions |
10 | 60 | 6F | AVS-10x60-6F | Slightly longer coverage in the same diameter |
14 | 60 | 7F | AVS-14x60-7F | Popular mid-range diameter for common iliofemoral lesions |
14 | 80 | 7F | AVS-14x80-7F | Extended length for multi-segment stenoses |
16 | 80 | 8F | AVS-16x80-8F | Enhanced diameter for advanced venous outflow compromise |
16 | 100 | 8F | AVS-16x100-8F | Longer coverage in larger veins |
20 | 120 | 9F | AVS-20x120-9F | Maximum diameter & length for extensive venous pathology |
Produtos Relacionados
-
Mantis PRO Trombectomia rotacional e ultra-aspiração
Ler maisA rotacional sistema com caraterísticas para mecânico fragmentação do coágulo mais forte capacidades de aspiração em oclusões venosas ou arteriais profundas.
-
NeuroFill
Ler maisPrecision Liquid Embolic para MAVs, aneurismas e anomalias neurovasculares.
-
Peta Descompressão mecânica percutânea do disco
Ler maisConcebido com materiais de engenharia de precisão, este dispositivo minimamente invasivo permite a descompressão eficaz de hérnias discais, aliviando a pressão sobre os nervos espinais e aliviando a dor, ao mesmo tempo que promove uma recuperação mais rápida.
-
Mantis XP Sistema de trombectomia para fístula
Ler maisA de alta potência dispositivo mecânico de trombectomia para oclusões venosas ou arteriais profundas, suportando um alcance alargado e uma extração robusta do coágulo em anatomias complexas.