Atlas 정맥 스텐트
생체 적합성 금속 합금으로 만들어진 특수 임플란트 시스템으로 혈관 개통성을 유지하고 혈류를 개선하며 만성 정맥 기능 부전의 증상을 완화하여 정맥 폐쇄를 치료하도록 설계되었습니다.
그리고 Atlas™ Venous Stent, introduced by Invamed-a 글로벌 의료 기기 제조업체—is meticulously crafted for venous outflow restoration and chronic venous insufficiency management. Leveraging a 자체 확장 nitinol design, Atlas™ offers strong radial force, adaptive conformability, and minimal recoil, supporting 내구성 patency in challenging venous anatomies.
Self-Expanding Nitinol Framework
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
High Conformability
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Minimal Recoil & Migration
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Optimized for Venous Hemodynamics
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Wide Clinical Utility
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
금기 사항
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Technical Specifications
사양 | 세부 정보 / 값 |
제품 이름 | Atlas™ Venous Stent |
Stent Material | Nitinol (nickel-titanium) self-expanding alloy |
배포 메커니즘 | Over-the-wire via introducer sheath (typically 6F–9F, model-specific) |
방사형 힘 | Moderate to high, designed to resist extrinsic compression |
스텐트 직경 범위 | ~10–20 mm nominal (expanded), ensuring coverage of varied venous lumen sizes |
Stent Length Range | ~40–120 mm, accommodating short or long-segment lesions |
불투명 마커 | Proximal and distal markers for fluoroscopic visualization |
무균 | Sterile, single use |
유통 기한 | ~3–5 years if stored at 15–25 °C |
임상 적응증 | Iliofemoral venous stenosis, post-thrombotic syndrome, extrinsic compression (May-Thurner), chronic venous insufficiency |
Size & Ordering Matrix
Stent Diameter (mm) | Stent Length (mm) | Sheath Compatibility (F) | 제품 코드 | 참고 |
10 | 40 | 6F | AVS-10x40-6F | Smaller diameter for narrower veins or moderate lesions |
10 | 60 | 6F | AVS-10x60-6F | Slightly longer coverage in the same diameter |
14 | 60 | 7F | AVS-14x60-7F | Popular mid-range diameter for common iliofemoral lesions |
14 | 80 | 7F | AVS-14x80-7F | Extended length for multi-segment stenoses |
16 | 80 | 8F | AVS-16x80-8F | Enhanced diameter for advanced venous outflow compromise |
16 | 100 | 8F | AVS-16x100-8F | Longer coverage in larger veins |
20 | 120 | 9F | AVS-20x120-9F | Maximum diameter & length for extensive venous pathology |
연관 상품
-
AngioCATH 유도 카테터
더 보기고성능 가이드 카테터는 다음과 같습니다. 최적의 토크 응답 및 정확한 팁 모양 관상동맥 또는 주변기기 개입하여 안정적인 디바이스 전달과 영상 선명도를 보장합니다.
-
Mantis 커브 오버더와이어(OTW) 회전식 약역학적 혈전 절제 시스템
더 보기An 유선 (OTW) 장치 병합 회전 의 중단 약리학 를 용해하여 건강한 혈관벽을 보호하면서 큰 혈전을 효과적으로 제거합니다.
-
Mantis XP Thrombectomy System for Fistula
더 보기A high-powered mechanical thrombectomy device for deep venous or arterial occlusions, supporting extended reach and robust clot extraction in complex anatomies.
-
InWIRE 주변 가이드 와이어
더 보기여러 주변기기 전선 구성(친수성, 강성, 교환 길이)을 용이하게 합니다. 안전 복잡하거나 석회화된 병변을 교차하고 안정적인 디바이스 지원을 보장합니다.