Atlas 정맥 스텐트
생체 적합성 금속 합금으로 만들어진 특수 임플란트 시스템으로 혈관 개통성을 유지하고 혈류를 개선하며 만성 정맥 기능 부전의 증상을 완화하여 정맥 폐쇄를 치료하도록 설계되었습니다.
그리고 Atlas™ Venous Stent, introduced by Invamed-a 글로벌 의료 기기 제조업체—is meticulously crafted for venous outflow restoration and chronic venous insufficiency management. Leveraging a 자체 확장 nitinol design, Atlas™ offers strong radial force, adaptive conformability, and minimal recoil, supporting 내구성 patency in challenging venous anatomies.
Self-Expanding Nitinol Framework
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
High Conformability
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Minimal Recoil & Migration
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Optimized for Venous Hemodynamics
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Wide Clinical Utility
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
금기 사항
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Delivers consistent radial force to maintain lumen patency, especially in large, compressible venous segments.
Adapts to tortuous or dynamic venous structures (e.g., iliac vein, femoral vein), minimizing stress at stent edges and promoting stable apposition.
Engineered for durable scaffolding, preserving vessel diameter and reducing the risk of stent migration under variable venous pressures.
Large cell design fosters robust flow, reducing intraluminal pressure gradients and supporting potential reduction in venous hypertension symptoms.
Indicated for iliofemoral venous outflow obstructions, post-thrombotic syndrome, or venous stenoses from extrinsic compression or scar tissue.
Severe vessel tortuosity or diameter mismatch preventing stent passage, active local infection in the venous target, or contraindications to endovascular procedures.
Technical Specifications
사양 | 세부 정보 / 값 |
제품 이름 | Atlas™ Venous Stent |
Stent Material | Nitinol (nickel-titanium) self-expanding alloy |
배포 메커니즘 | Over-the-wire via introducer sheath (typically 6F–9F, model-specific) |
방사형 힘 | Moderate to high, designed to resist extrinsic compression |
스텐트 직경 범위 | ~10–20 mm nominal (expanded), ensuring coverage of varied venous lumen sizes |
Stent Length Range | ~40–120 mm, accommodating short or long-segment lesions |
불투명 마커 | Proximal and distal markers for fluoroscopic visualization |
무균 | Sterile, single use |
유통 기한 | ~3–5 years if stored at 15–25 °C |
임상 적응증 | Iliofemoral venous stenosis, post-thrombotic syndrome, extrinsic compression (May-Thurner), chronic venous insufficiency |
Size & Ordering Matrix
Stent Diameter (mm) | Stent Length (mm) | Sheath Compatibility (F) | 제품 코드 | 참고 |
10 | 40 | 6F | AVS-10x40-6F | Smaller diameter for narrower veins or moderate lesions |
10 | 60 | 6F | AVS-10x60-6F | Slightly longer coverage in the same diameter |
14 | 60 | 7F | AVS-14x60-7F | Popular mid-range diameter for common iliofemoral lesions |
14 | 80 | 7F | AVS-14x80-7F | Extended length for multi-segment stenoses |
16 | 80 | 8F | AVS-16x80-8F | Enhanced diameter for advanced venous outflow compromise |
16 | 100 | 8F | AVS-16x100-8F | Longer coverage in larger veins |
20 | 120 | 9F | AVS-20x120-9F | Maximum diameter & length for extensive venous pathology |
연관 상품
-
Nexus 정맥 및 동맥 캐뉼라
더 보기다목적 정맥 그리고 동맥 캐뉼라 지원 체외 순환 심폐 우회술 또는 에크모 사용 시 최적의 유량 그리고 혈액형 호환성.
-
VenoNeedle® 소정맥 RF 절제 시스템
더 보기A 저전력 다음을 목표로 하는 열 시스템 거미 정맥, 모세혈관 확장증 또는 작은 망상 정맥류를 동반한 정밀한 응고를 통해 큰 절개나 장시간의 가동 중단을 방지합니다.
-
NeuroFill
더 보기동정맥류, 동맥류 및 신경혈관 이상을 위한 정밀 액체 색전술.
-
ICT 내부 압박 요법
더 보기ICT 판막 누출 실러 재건 시스템
ICT는 기능 장애 정맥 판막에 대한 내부 압박 요법입니다. 이 시술은 경피적 판막 성형술이라고도 합니다.