AngioHAND Catéter de extracción de coágulos
A manipulación manual dispositivo de aspiración mecánica que permite extracción del coágulo a través de un manual de vacío, simplificando los procedimientos de trombectomía aguda.
The AngioHAND Clot Removal Catheter by Invamed is a hand-operated mechanical aspiration system designed to immediately remove thrombi or emboli during acute vascular occlusions. Featuring braided balloon-shaped structures, the catheter actively captures clots and pulls them into the lumen, enabling safe, streamlined thrombectomy without complex capital equipment or continuous vacuum lines. Ideal for distal or proximal arterial/venous clots, AngioHAND simplifies acute stroke, limb ischemia, or DVT management.
Braided Balloon-Shaped Capture
- Expandable mesh or braided balloon segments at the distal tip engage and enclose clot mass, guiding it into the catheter lumen.
- Ensures robust clot entrapment without excessive fragmentation or distal embolization.
Manual Vacuum Mechanism
- Operated by a hand-held syringe-like device or integrated handle, creating a controlled negative pressure to aspirate clot into the catheter shaft.
- Minimizes procedural complexity—no large vacuum pumps—offering immediate aspiration capacity at the bedside or in urgent OR settings.
Rapid & Intuitive Thrombectomy
- Inserted percutaneously via a small arterial or venous access; navigated under fluoroscopic guidance to the occlusion site.
- One-hand manipulation of the aspiration handle triggers vacuum and clot removal in real-time, optimizing speed and efficiency.
Enhanced Safety & Vessel Protection
- Balloon-shaped braids gently expand against the vessel walls, preventing the catheter tip from causing undue trauma.
- Reduces the risk of iatrogenic injuries and maintains patency around the extraction zone for improved patient outcomes.
Multiple Clinical Indications
- Acute ischemic stroke retrieval in cerebral arteries (depending on vessel diameter and regulatory approvals).
- Peripheral arterial occlusions (e.g., acute limb ischemia, popliteal thrombosis) or venous thrombi (DVT).
- Use in emergent or elective procedures where fast mechanical clot extraction is paramount.
Especificaciones del producto
Especificación | Detalle / Valor |
Nombre del producto | AngioHAND Catéter de extracción de coágulos |
Uso previsto | Manual vacuum-based aspiration of thrombus, emboli, or clot debris in peripheral or coronary vessels |
Diseño del catéter | Hand-operated syringe or vacuum-based system, flexible polymer shaft with a soft distal tip |
Diámetro exterior | ~5F–7F (depending on model) |
Lumen Inner Diameter | Large bore optimized for clot aspiration |
Longitud de trabajo | ~80–120 cm (varies by product code) |
Configuración de la punta | Tapered or funnel-shaped tip to facilitate clot ingress |
Marcador radiopaco | Distal marker band for fluoroscopic location |
Vacuum Mechanism | Manual hand-syringe or integrated vacuum lock (no external pump required) |
Esterilidad | Estéril, un solo uso |
Vida útil | ~2–3 years at 15–25 °C |
Indicaciones clínicas | Acute clot removal in peripheral arteries/veins, smaller coronary vessels, or bypass grafts |
Contraindicaciones | Severe vessel tortuosity, extremely large clot burden exceeding device capacity, known device material allergy |
Matriz de pedidos y tamaños
Diámetro exterior (F) | Longitud de trabajo (cm) | Tip Style | Código del producto | Notas |
5F | 80 | Tapered Soft Tip | ANG-HND-5F-80-TS | Smaller diameter for coronary or distal peripheral |
5F | 100 | Funnel Tip | ANG-HND-5F-100-FN | Moderate length, manual vacuum approach |
6F | 80 | Tapered Soft Tip | ANG-HND-6F-80-TS | Common size for peripheral thrombus aspiration |
6F | 120 | Funnel Tip | ANG-HND-6F-120-FN | Extended length for deeper occlusion sites |
7F | 100 | Tapered Soft Tip | ANG-HND-7F-100-TS | Larger lumen for heavier clot burden |
7F | 120 | Funnel Tip | ANG-HND-7F-120-FN | Maximum length plus funnel design for wide clot removal |
Productos relacionados
-
Extender Catéter balón PTCA liberador de fármaco Paclitaxel
Leer másA recubierto de paclitaxel catéter coronario de balón dirigido a reducir la reestenosis durante la angioplastia coronaria transluminal percutánea (ACTP), garantizando la administración eficaz del fármaco a la pared vascular.
-
Mantis CURVE Over-the-Wire (OTW) Rotational Pharmacomechanical Thrombectomy System
Leer másEn over-the-wire (OTW) device merging rotacional disruption with pharmacologic lysis, effectively clearing large thrombi while protecting healthy vessel walls.
-
NOD Valvulotome
Leer másA titanio o aleación sistema de placa esternal que proporciona rígido fijación tras la esternotomía media, mejorando estabilidad esternal y reducir los riesgos de infección o dehiscencia tras la cirugía cardíaca.
-
VascuVac Tecnologías de trombectomía de vacío asistida por Ai
Leer másUn sistema innovador que utiliza tecnología asistida por IA para una trombectomía de vacío eficaz, diseñado para eliminar rápidamente los trombos de los vasos sanguíneos, restablecer el flujo sanguíneo, y minimizar los riesgos del procedimiento en intervenciones vasculares.