Inca® Embolism Protective System
A catéter entrega trombolítico agentes mientras filtro impide la embolización distal, garantizando una disolución farmacológica más segura de los coágulos.
En Inca® Embolism Protective System es un small, nitinol-based filtration device designed to capture embolic material released during interventional procedures in the carotid artery, lower extremity arterial segments, and other vascular sites. By offering distal protection against plaque or thrombus fragments dislodged during angioplasty, stenting, or other endovascular interventions, Inca enhances patient safety y procedure efficiency—enabling clinicians to maintain unobstructed distal flow while reducing the risk of embolic complications.
Nitinol Filtration Cage
- Shape-Memory Alloy: The self-expanding nitinol structure conforms to vessel lumens, helping to securely capture dislodged debris and prevent distal embolization.
- Minimal Profile: Compact, low-profile design ensures smooth insertion and objetivo deployment in narrow or tortuous arteries.
Distal Placement
- Downstream Protection: Positioned beyond the site of intervention, Inca effectively traps microscopic or larger debris, safeguarding distal vasculature from occlusion.
- Precise Positioning: Engineered radiopacity facilitates real-time visualization under fluoroscopy, enabling accurate filter placement.
Deployment & Retrieval Mechanism
- User-Friendly Delivery System: Allows rápido y controlado expansion of the filter cage at the desired location.
- Safe Filter Retrieval: Collapses the nitinol mesh into a low-profile sheath post-procedure, retaining captured material for removal without vessel injury.
Broad Vascular Applicability
- Carotid Interventions: Decreases stroke risk from plaque dislodgement during carotid stenting or angioplasty.
- Peripheral Procedures: Protects lower extremity arteries from fragmented thrombus during limb revascularization.
- Coronary Interventions (where indicated): Potentially usable to prevent distal embolization in certain coronary interventions (depending on labeling).
- Shape-Memory Alloy: The self-expanding nitinol structure conforms to vessel lumens, helping to securely capture dislodged debris and prevent distal embolization.
- Minimal Profile: Compact, low-profile design ensures smooth insertion and objetivo deployment in narrow or tortuous arteries.
- Downstream Protection: Positioned beyond the site of intervention, Inca effectively traps microscopic or larger debris, safeguarding distal vasculature from occlusion.
- Precise Positioning: Engineered radiopacity facilitates real-time visualization under fluoroscopy, enabling accurate filter placement.
- User-Friendly Delivery System: Allows rápido y controlado expansion of the filter cage at the desired location.
- Safe Filter Retrieval: Collapses the nitinol mesh into a low-profile sheath post-procedure, retaining captured material for removal without vessel injury.
- Carotid Interventions: Decreases stroke risk from plaque dislodgement during carotid stenting or angioplasty.
- Peripheral Procedures: Protects lower extremity arteries from fragmented thrombus during limb revascularization.
- Coronary Interventions (where indicated): Potentially usable to prevent distal embolization in certain coronary interventions (depending on labeling).
Especificaciones del producto
Especificación | Detalle / Valor |
Nombre del producto | Inca Thrombolysis Catheter with Protection Filter |
Uso previsto | Pharmacological thrombolysis of acute or subacute thrombi in peripheral or venous systems, featuring a built-in filter to catch embolic debris |
Diseño del catéter | Multi-lumen catheter with distal infusion ports, integrated filter basket or net |
Material | Pebax/Polyamide shaft, nitinol or stainless steel filter frame |
Diámetro exterior (F) | ~4–6F (depending on infusion lumen size) |
Longitud de trabajo | ~80–120 cm (varies by code) |
Infusion Ports | Side holes over a specified segment for uniform drug distribution |
Filter Mechanism | Collapsible mesh near distal tip to capture dislodged debris |
Compatibilidad de guías | Typically 0.014” or 0.018” |
Esterilidad | Estéril, un solo uso |
Vida útil | ~2-3 años si se almacena a 15-25 °C en envase cerrado |
Indicaciones clínicas | Catheter-directed thrombolysis (e.g., in DVT, peripheral arterial occlusions), preventing distal embolization |
Contraindicaciones | Excessive vessel tortuosity, large-bore clots exceeding filter capacity, known intolerance to materials |
Matriz de pedidos y tamaños
Diámetro exterior (F) | Longitud de trabajo (cm) | Infusion Segment (cm) | Filter Diameter (mm) | Código del producto |
4F | 80 | 10 | 10 | INC-4F-80-10-10 |
4F | 100 | 15 | 12 | INC-4F-100-15-12 |
5F | 80 | 10 | 14 | INC-5F-80-10-14 |
5F | 120 | 20 | 14 | INC-5F-120-20-14 |
6F | 80 | 15 | 33 | INC-6F-80-15-16 |
6F | 120 | 20 | 33 | INC-6F-120-20-18 |