Rapid and Reliable Embolization for Critical Moments
- The Filler Cyanoacrylate-Based Embolization Agent is distinguished by its rapid polymerization and targeted application, ensuring immediate and reliable vessel occlusion.
- Filler works by causing an inflammatory reaction over the endothelium of the target vein upon the injection of the polymer and simultaneous pressure application.
Secure Occlusion, Superior Outcomes
- Its high-viscosity formulation and compatibility with standard catheters enhance control during application, minimizing the risk of non-target embolization.
- Filler was developed for the treatment of peripheral and neurovascular, including arteriovenous malformations and hypervascular tumors by a simple polymerization method.
- Small amounts of polymer were delivered endovenous and pressure of up to 2-3 minutes to applied for total closure.

CAN BE
PERFORMED
SAFELY
Filler: Precision Embolization, Promising Results
Designed for biocompatibility, Filler minimizes inflammatory responses post-embolization, promoting patient safety and recovery. Choose Filler for a cutting-edge embolization solution that delivers superior outcomes and sets the standard in vascular care.
- Agent Type: Cyanoacrylate-based embolization agent.
- Composition: A high-viscosity liquid embolic agent, consisting of cyanoacrylate, designed for controlled and targeted embolization.
- Mechanism of Action: Rapid polymerization upon contact with ionic substances such as blood, leading to instant vessel occlusion.
- Indications: Suitable for arteriovenous malformations, gastrointestinal bleeding, and pre-surgical embolization.
- Application: Delivered through standard catheters, allowing for precise application and minimization of non-target embolization.
- Biocompatibility: Designed to be biocompatible and minimize inflammatory responses post-embolization.
- Composition: A high-viscosity liquid embolic agent, consisting of cyanoacrylate, designed for controlled and targeted embolization.
FAST
EFFECTIVE
& EASY
Filler Cyanoacrylate-Based Embolization Agent stands out as a cutting-edge solution for targeted and rapid vascular occlusion. Its high-viscosity liquid form, comprised of cyanoacrylate, is expertly designed to ensure controlled application and immediate results.
Upon contact with ionic substances such as blood, Filler rapidly polymerizes, leading to instant and durable vessel occlusion. This makes it an ideal choice for critical applications such as arteriovenous malformations, gastrointestinal bleeding, and pre-surgical embolization. Its delivery through standard catheters ensures precise application, reducing the risk of non-target embolization and enhancing procedural success.

- Neuro Aneurysms and AVMs
- Abdominal Aneurysms, Endoleaks
- Neurovascular & Peripheral Aneurysms and AVMs
- Short procedure procedure time.
- Mix with lipiodol for radiopacity
Filler is delivered through a microcatheter into the AVM under fluoroscopic control.
Filler immediately forms a skin as the polymeric embolus solidifies from the outside to the inside, while traveling more distally in the vessel.
Type 2 endoleak from lumbar arteries. (A) Computed tomography (CT) scan in the procubitus position shows posterior opacification of the periprosthetic aneurysmal sac (nidus). (B) Embolization of the endoleak center with a microcatheter under CT guidance until nidus opacification is complete.
产品规格
规格 | 细节/价值 |
产品名称 | Filler Cyanoacrylate Embolization Agent |
预期用途 | Embolization of AVMs, fistulas, varices, or other lesions requiring permanent vascular occlusion |
Composition | n-Butyl or n-Hexyl cyanoacrylate formulation, polymerizes rapidly upon contact with blood/tissue |
Polymerization Mechanism | Instant polymerization triggered by ionic/aqueous environment |
Delivery Method | Via microcatheter (coaxial with DMSO or compatible flushing agent, if needed) |
辐射能力 | May require added radiopaque contrast (e.g., Lipiodol) for fluoroscopic visibility |
Viscosity | Low to medium (check final specs), allowing controlled injection time |
无菌 | 无菌,一次性使用 |
保质期 | 在 15-25 °C 密封包装中 ~2-3 年 |
临床适应症 | Neurovascular or peripheral AVM occlusion, gastrointestinal bleeders, variceal management, certain tumor devascularizations |
禁忌症 | Vessel lumens too small for catheter access, potential risk if accidental nontarget injection, known allergy to cyanoacrylates |
订购和尺寸表
Cyanoacrylate Concentration (%) | Vial Volume (mL) | Recommended Mixing Ratio | 产品代码 | 说明 |
33 | 1.0 | 1:1 with radiopaque agent | FIL-33-1.0-1:1 | Lower concentration, slower polymerization, suitable for distal lesions |
33 | 2.0 | 1:1 | FIL-33-2.0-1:1 | Larger vial, same concentration |
50 | 1.0 | 1:0.5 | FIL-50-1.0-1:0.5 | Faster set time, moderate volume |
50 | 2.0 | 1:0.5 | FIL-50-2.0-1:0.5 | Larger volume for multiple feeders |
67 | 1.0 | 1:0.25 | FIL-67-1.0-1:0.25 | High concentration, rapid polymerization for high-flow lesions |
67 | 2.0 | 1:0.25 | FIL-67-2.0-1:0.25 | Maximum control in large or complex AVMs |
相关产品
-
Atlas 主动脉镍钛诺支架
阅读更多A 自我膨胀 镍钛诺支架设计用于 主动脉 病变覆盖率,保持 灵活 径向力,以便在 胸腔 或 腹部 主动脉解剖
-
SteerCATH 可转向导管
阅读更多A 可转向 支撑导管 可挠 喷嘴,专为复杂或 支管 可用于冠状动脉和外周介入治疗。在具有挑战性的解剖结构中提高穿刺成功率。
-
Stena 主动脉多层流量调节器
阅读更多专门 多层支架 工程设计为 调节主动脉流量在不妨碍重要分支灌注的情况下,降低囊压并稳定动脉瘤。专为重塑以下部位的血液动力学而设计 胸或腹主动脉 病变,以改善长期疗效。
-
Pars 可拆卸栓塞导管
阅读更多A 导管 系统启用 有选择 微导管推进和 机械 或 化学 栓塞,其特点是远端 可拆卸 避免导管卡住的提示。