AngioTEN Closure Device
A percutaneous vascular closure system for 动脉 或 静脉 access sites, enabling 巩 hemostasis after catheterization or interventional procedures.
AngioTEN Closure Device by INVAMED is a cyanoacrylate-based closure system designed to seal and stabilize the access site after angiographic procedures. Equipped with a specialized applicator, it ensures precise and user-friendly application of the adhesive over vascular puncture sites, reducing bleeding complications and enhancing patient recovery. By combining rapid polymerization with a biocompatible formula, AngioTEN helps minimize pseudoaneurysm formation and shortens manual compression time—optimizing clinical workflow in catheterization labs.
Cyanoacrylate Adhesive Technology
Employs a fast-curing medical-grade cyanoacrylate that bonds rapidly to tissue edges, helping create a secure and durable seal at the arterial or venous puncture site.
Ergonomic Applicator
Features a slim, intuitive applicator that allows precise dropwise or thin-stripe application, ensuring minimal adhesive wastage and targeted closure even in narrow access points.
Rapid Hemostasis
By instantly sealing the puncture track, AngioTEN reduces the need for prolonged manual compression or adjunct compression devices, potentially improving patient comfort and catheter lab throughput.
Biocompatible & Safe
Formulated to minimize tissue irritation and promote natural healing processes. Ideal for radial or femoral access closure after diagnostic angiography or interventional procedures.
Reduced Risk of Complications
Stabilizing the access site lowers the incidence of hematoma, pseudoaneurysm, or AV fistula formation, supporting safer vascular interventions and quicker discharge protocols.
禁忌症
- Heavy calcification, severely diseased artery walls
- Uncontrolled bleeding or coagulopathy beyond standard care measures
- Infection at the puncture site
产品规格
规格 | 细节/价值 |
产品名称 | AngioTEN Closure Device |
预期用途 | Percutaneous vascular closure post-catheterization |
Closure Mechanism | Suture-mediated or collagen plug |
Applicable Access Sites | Femoral artery/vein up to 8F–10F introducer sizes |
Deployment Method | Single-step device insertion and anchor release |
Hemostasis Time | Typically < 1 minute post-deployment |
无菌 | 无菌,一次性使用 |
保质期 | ~2–3 years at 15–25 °C |
订购和尺寸表
Access Size (F) | Closure Method | Deployment Steps | 产品代码 |
5–8 | Collagen Plug | Single | ATN-CP-5-8-S |
5–8 | Suture-Mediated | Single | ATN-SM-5-8-S |
8–10 | Collagen Plug | Single | ATN-CP-8-10-S |
8–10 | Suture-Mediated | Single | ATN-SM-8-10-S |
相关产品
-
Keeper 血管内卡环
阅读更多A 多回路 捕捉器 异物 或 栓塞 捕获,确保 巩 参与和 退出 来自血管腔。
-
ATLAS Drug Eluting Coronary Stent System Cobalt Chromium
阅读更多A cobalt-chromium coronary stent delivering durable radial strength 和 excellent trackability, suited for complex 或 calcified coronary lesions while ensuring minimal recoil.
-
Atlas 冠状动脉支架移植系统
阅读更多A 有盖冠状动脉支架 系统提供 腔外 密封 齿孔 或 假性动脉瘤从而在保持冠状动脉通畅的同时防止外渗。
-
AngioCATH 导引导管
阅读更多具有以下功能的高性能导引导管 最佳扭矩 反应和 精确提示 形状为 冠脉 或 外围 干预,确保稳定的设备输送和成像清晰度。