UroGuide 가이드 와이어
정밀하게 설계된 가이드 와이어는 비뇨기과 시술 시 탁월한 제어력과 유연성을 제공하도록 설계되어 요로에 대한 원활한 탐색과 향상된 접근을 보장합니다.
UroGuide presents a comprehensive range of guide wires for diverse urological and vascular interventions, ensuring precise placement, smooth device tracking, and kink-resistant performance. From standard PTFE-coated stainless steel wires to advanced nitinol-core hydrophilic options, UroGuide guide wires are engineered to support clinicians in tackling a variety of anatomical challenges while enhancing procedural 효율성 및 patient safety.
Standard – PTFE-Coated Stainless Steel
- Reliable Basic Wire: Combines a stainless steel core with PTFE coating for low friction and straightforward manipulation.
- Versatile, Cost-Effective: Suitable for routine procedures requiring stable wire support in both diagnostic and therapeutic interventions.
Lunderquist – PTFE-Coated Stainless Steel
- Extra Stiff Core: Offers superior pushability, especially in long or tortuous anatomies.
- Enhanced Control: Ideal for complex navigation during endourological or peripheral vascular access.
Guide Wire with Movable Core – PTFE-Coated Stainless Steel
- Adjustable Stiffness: The movable inner core allows tailored flexibility or rigidity, adapting in real time to the demands of the procedure.
- Precision Placement: Balances trackability and support, facilitating accurate instrument exchange and positioning.
Uncoated Stainless Steel Wire
- Friction-Controlled: Maintains a simpler surface if PTFE coating is not required or if direct tactile feedback is preferred.
- General Use: Offers a basic, stable foundation for less complex manipulations.
Tiger Guide Wire
Black-Yellow Swivel Design
- Improved Wire Movement Control: The unique black-yellow swirl provides a visual reference for real-time torque application and orientation feedback.
- Enhanced Operator Handling: Operators can more easily gauge wire twist and rotation, reducing the risk of unintended wire movements.
Nitinol Core
- Kink Resistance: Maintains shape integrity even under repeated angulations or maneuvers through tight anatomies.
- Consistent Wire Memory: Superelastic nitinol resists permanent deformation, ensuring reliable reusability (as permitted by local protocols).
PTFE Coating
- Easy & Fast Placement: The lubricious surface lowers friction during vessel or ureter navigation, streamlining device insertion.
- Optimized Gliding: Minimizes trauma to the ureter or vascular endothelium, thus enhancing patient comfort and reducing complication rates.
임상적 이점 및 애플리케이션
Broad Spectrum of Procedures
- Urological Endoscopy: Facilitates ureteral stent placement, stone retrieval, or upper tract interventions with minimal friction.
- Percutaneous Access: Vital in establishing reliable vascular entry for catheters, sheath introduction, or device deliverability (e.g., nephrostomy, arterial/venous interventions).
Versatile Diameter & Tip Configurations
- Multiple Profiles: Matches operator preference—whether for stiff push or flexible tip.
- Effective in Challenging Anatomies: Options for extra-stiff support, adjustable stiffness, or high lubricity ensure a solution for each complexity level.
Reduced Risk of Kinking & Improved Device Control
- Nitinol or Stiff Core: Ensures stable navigation in S-shaped or heavily calcified pathways, preserving wire position and lowering procedure times.
- PTFE or Hydrophilic Layers: Minimizes friction, protecting mucosal surfaces and diminishing the potential for wire-induced complications.
Enhanced Safety & Patient Comfort
- Minimal Tissue Trauma: Smooth coatings and flexible design help avoid inadvertent injury to ureteral or vascular walls.
- Fewer Exchanges: High-performance wires can obviate repeated wire switching, benefiting both the clinical workflow and patient experience.
UroGuide GUIDE WIRES
Wire Series | Core Material | Surface | Key Feature |
Standard PTFE-Coated | Stainless Steel | PTFE Coating | Basic friction reduction, stable engineering |
Lunderquist (PTFE-Coated) | Stainless Steel (Extra Stiff) | PTFE Coating | Enhanced push, complex vessel usage |
Movable Core (PTFE-Coated) | Stainless Steel (Adjustable) | PTFE Coating | Variable stiffness for real-time adjustments |
Uncoated Stainless Steel | Stainless Steel (No Coating) | Uncoated | Direct tactile feedback, simpler approach |
Tiger Guide Wire | Nitinol | PTFE Coating | Black-yellow swirl, improved torque control |
Hydrophilic-Coated | Nitinol | Hydrophilic (Water-Activated) | High lubricity, kink resistance, minimal friction |
연관 상품
-
AngioCATH 유도 카테터
더 보기고성능 가이드 카테터는 다음과 같습니다. 최적의 토크 응답 및 정확한 팁 모양 관상동맥 또는 주변기기 개입하여 안정적인 디바이스 전달과 영상 선명도를 보장합니다.
-
UroLase: 방광 종양에 대한 레이저 경요도 절제술
더 보기방광 종양에 대한 레이저 경요도 절제술: 요도를 통해 방광 종양을 정밀하게 절제하도록 설계된 최첨단 레이저 시스템으로, 최소 침습, 출혈 감소, 향상된 정밀도를 제공하여 효과적인 종양 제거가 가능합니다.
-
UroFlow 요관 스텐트
더 보기요류가 막히지 않도록 설계된 이 생체 적합성 스텐트는 요관을 안정적으로 지지하여 비뇨기과적 폐쇄를 관리하는 동안 치유를 촉진하고 편안함을 제공합니다.
-
Atlas 관상동맥 스텐트 그라프트 시스템
더 보기A 커버드 관상동맥 스텐트 시스템 제공 외형 밀봉 천공 또는 가성 동맥류를 사용하여 관상동맥 개통성을 유지하면서 혈관 외 유출을 방지합니다.