ThermoBLOCK 하지정맥류 고주파 절제 시스템
A radiofrequency ablation platform for incompetent superficial veins, offering thermal closure of saphenous or perforating veins to relieve varicose symptoms.
그리고 Thermal Coagulation RF Ablation Generator 는 고급, feedback-driven system designed to deliver high-frequency radiofrequency (RF) energy 에 ThermoBLOCK™ catheters 그리고 ThermoBLOCK™ stylets—enabling 대상 thermal ablation for chronic venous insufficiency (CVI). Equipped with a 실시간 monitoring mechanism, the generator precisely regulates intravascular heat parameters, ensuring 안전 그리고 consistent power application while protecting surrounding tissues.
Real-Time Feedback Control
- Heat Parameter Monitoring: Intravascular temperature readings and impedance data are continuously analyzed.
- Automatic Power Regulation: The system modulates RF output based on real-time feedback, maintaining stable thermal therapy without over- or under-heating the vein walls.
Precision RF Delivery
- Targeted Vessel Closure: Concentrates thermal energy along the catheter’s active tip(s), leading to collapsing 그리고 sealing of incompetent veins.
- 부수적 피해 최소화: By adapting energy output to real-time conditions, the generator reduces risk of inadvertent injury to neighboring structures.
사용자 친화적인 인터페이스
- Digital Touchscreen or Control Panel: Operators can easily set and adjust parameters (power, pulse duration, temperature limits) as needed.
- Visual & Audible Cues: Real-time displays of energy output, therapy time, and any alerts keep clinicians informed.
Versatile Integration
- ThermoBLOCK™ Catheter & Stylet Compatibility: Specifically engineered to function seamlessly with ThermoBLOCK™ components, streamlining venous ablation procedures.
- Multi-Mode Operation: Adjustable settings accommodate various vein diameters and lesion characteristics, benefiting physicians performing different CVI treatments.
- Heat Parameter Monitoring: Intravascular temperature readings and impedance data are continuously analyzed.
- Automatic Power Regulation: The system modulates RF output based on real-time feedback, maintaining stable thermal therapy without over- or under-heating the vein walls.
- Targeted Vessel Closure: Concentrates thermal energy along the catheter’s active tip(s), leading to collapsing 그리고 sealing of incompetent veins.
- 부수적 피해 최소화: By adapting energy output to real-time conditions, the generator reduces risk of inadvertent injury to neighboring structures.
- Digital Touchscreen or Control Panel: Operators can easily set and adjust parameters (power, pulse duration, temperature limits) as needed.
- Visual & Audible Cues: Real-time displays of energy output, therapy time, and any alerts keep clinicians informed.
- ThermoBLOCK™ Catheter & Stylet Compatibility: Specifically engineered to function seamlessly with ThermoBLOCK™ components, streamlining venous ablation procedures.
- Multi-Mode Operation: Adjustable settings accommodate various vein diameters and lesion characteristics, benefiting physicians performing different CVI treatments.
제품 사양
사양 | 세부 정보 / 값 |
제품 이름 | ThermoBLOCK Varicose Vein RF Ablation System |
사용 목적 | Endovenous radiofrequency ablation (RFA) of incompetent saphenous or perforator veins |
RF Catheter Design | 6–7F catheter with electrode segment near distal tip, temperature-controlled |
Nominal Power | ~10–30 W (depends on vein diameter and system setting) |
카테터 길이 | ~60–120 cm (varies by code) |
Generator Compatibility | ThermoBLOCK RF Generator or universal 460 kHz system |
Temperature Monitoring | Integrated thermocouple in ablation segment |
Treatment Cycle | Typically ~20–40 seconds per segment, auto-regulated by temperature feedback |
무균 | 멸균, 일회용 |
유통 기한 | ~2–3 years at 15–25 °C |
임상 적응증 | Great saphenous vein (GSV) reflux, small saphenous vein, perforator incompetence |
금기 사항 | Unclear vein anatomy, severe peripheral arterial disease, known intolerance to device materials |
주문 및 사이즈 매트릭스
카테터 크기(F) | 카테터 길이(cm) | Ablation Segment (cm) | 제품 코드 | 참고 |
6F | 60 | 7 | TBLK-6F-60-7 | Short catheter for small segments |
6F | 100 | 7 | TBLK-6F-100-7 | Standard ablation length, extended shaft |
7F | 100 | 10 | TBLK-7F-100-10 | Longer ablation segment for large GSV trunk |
7F | 120 | 10 | TBLK-7F-120-10 | For taller patients or more extensive reflux |
7F | 120 | 15 | TBLK-7F-120-15 | Extra ablation segment for major trunk veins |