MultiBEAM 하대정맥(IVC) 필터
A convertible or retrievable IVC filter preventing pulmonary emboli by intercepting clots traveling through the inferior vena cava, ensuring safety in high-risk patients.
The MultiBEAM Inferior Vena Cava (IVC) Filter, offered by Invamed—a global medical device manufacturer—is designed to capture and retain thromboembolic fragments traveling within the venous system, thereby reducing the risk of pulmonary embolism (PE). Featuring a self-expanding metallic framework, MultiBEAM provides robust fixation in the IVC while facilitating high patency and stable clot containment.
Self-Expanding Nitinol Struts
Engineered from a biocompatible alloy for secure anchoring, even under shifting venous pressures.
Multi-Spoke or “Beam” Design
Creates multiple capture zones that efficiently trap emboli without significantly restricting blood flow, sustaining venous return.
Retrievable/Optional Permanent
Certain models allow retrieval within a designated window, while others function as permanent PE prophylaxis solutions—offering clinicians flexibility in management.
Reduced Migration & Tilt
Precisely balanced struts help prevent filter migration or tilting, enhancing performance consistency over time.
Wide Application Scope
Indicated for patients at elevated PE risk due to venous thromboembolism (VTE), inadequate response to anticoagulants, or temporary contraindications to anticoagulation therapy.
금기 사항
Excessively narrow or tortuous IVC diameter preventing secure seating, active infection at insertion site, or patient-specific anatomical constraints.
제품 사양
| 사양 | 세부 정보 / 값 |
| 제품 이름 | MultiBEAM 하대정맥(IVC) 필터 |
| 사용 목적 | Prevention of pulmonary embolism by capturing clots traveling from lower extremity or pelvic veins |
| Filter Design | Self-expanding metal struts (Nitinol or stainless steel) arranged in a multi-beam pattern |
| 배포 메커니즘 | Over-the-wire or sheath-based insertion, typically via femoral or jugular access |
| Retrieval Option | Some models are optionally retrievable within a specific timeframe (check product line) |
| Filter Diameter Range | Suited for IVC diameters ~20–30 mm (varies by product code) |
| 불투명 마커 | Distal apex or anchor tips for fluoroscopic identification |
| MR 호환성 | MR Conditional (verify labeling) |
| 무균 | 멸균, 일회용 |
| 유통 기한 | ~3–5 years if stored at 15–25 °C in sealed packaging |
| 임상 적응증 | Patients at risk of pulmonary embolism (PE), especially with contraindications to anticoagulation |
| 금기 사항 | Severe IVC anatomical anomalies, high-level occlusion, known allergy to device materials |
주문 및 사이즈 매트릭스
| IVC Diameter Suitability (mm) | Filter Apex to Anchor (mm) | Retrieval Window (days) | 제품 코드 | 참고 |
| < 24 | 26 | 30 | MBI-<24-40-30 | Smaller IVC or narrow diameters |
| < 24 | 26 | 90 | MBI-<24-50-90 | Extended retrieval time |
| 20–28 | 33 | 30 | MBI-20-28-50-30 | Common range for standard IVC diameters |
| 20–28 | 33 | 90 | MBI-20-28-60-90 | Longer apex distance + extended retrieval |
| 28–30 | 33 | 30 | MBI-28-30-60-30 | For larger IVC diameter, shorter retrieval |
| 28–30 | 33 | 90 | MBI-28-30-70-90 | Largest apex span + extended retrieval |
연관 상품
-

AngioCATH 유도 카테터
더 보기고성능 가이드 카테터는 다음과 같습니다. 최적의 토크 응답 및 정확한 팁 모양 관상동맥 또는 주변기기 개입하여 안정적인 디바이스 전달과 영상 선명도를 보장합니다.
-

Mantis PRO 회전 혈전 절제술 및 울트라 흡인
더 보기A 회전 시스템 기능 기계 혈전 조각화 플러스 강한 심부 정맥 또는 동맥 폐색에서 흡인 기능을 제공합니다.
-

ICT 내부 압박 요법
더 보기ICT 판막 누출 실러 재건 시스템
ICT는 기능 장애 정맥 판막에 대한 내부 압박 요법입니다. 이 시술은 경피적 판막 성형술이라고도 합니다.
-

Extender PTCA 풍선 카테터
더 보기A 표준 고압 관상동맥 풍선 설계 대상 병변 박리 또는 독립형 혈관 성형술를 사용하여 정확한 인플레이션 프로파일과 감소된 교차 프로파일을 제공합니다.