Filler 시아노아크릴레이트 기반 색전술 에이전트
A 시아노아크릴레이트 색전증용 접착제 혈관 또는 AVM 오클루전, 오퍼링 빠른 혈액과 접촉하면 중합되어 안정적인 혈관 밀봉과 최소한의 아티팩트를 보장합니다.
Rapid and Reliable Embolization for Critical Moments
- The Filler Cyanoacrylate-Based Embolization Agent is distinguished by its rapid polymerization and targeted application, ensuring immediate and reliable vessel occlusion.
- Filler works by causing an inflammatory reaction over the endothelium of the target vein upon the injection of the polymer and simultaneous pressure application.
Secure Occlusion, Superior Outcomes
- Its high-viscosity formulation and compatibility with standard catheters enhance control during application, minimizing the risk of non-target embolization.
- Filler was developed for the treatment of peripheral and neurovascular, including arteriovenous malformations and hypervascular tumors by a simple polymerization method.
- Small amounts of polymer were delivered endovenous and pressure of up to 2-3 minutes to applied for total closure.

CAN BE
PERFORMED
SAFELY
Filler: Precision Embolization, Promising Results
Designed for biocompatibility, Filler minimizes inflammatory responses post-embolization, promoting patient safety and recovery. Choose Filler for a cutting-edge embolization solution that delivers superior outcomes and sets the standard in vascular care.
- Agent Type: Cyanoacrylate-based embolization agent.
- Composition: A high-viscosity liquid embolic agent, consisting of cyanoacrylate, designed for controlled and targeted embolization.
- Mechanism of Action: Rapid polymerization upon contact with ionic substances such as blood, leading to instant vessel occlusion.
- Indications: Suitable for arteriovenous malformations, gastrointestinal bleeding, and pre-surgical embolization.
- Application: Delivered through standard catheters, allowing for precise application and minimization of non-target embolization.
- Biocompatibility: Designed to be biocompatible and minimize inflammatory responses post-embolization.
- Composition: A high-viscosity liquid embolic agent, consisting of cyanoacrylate, designed for controlled and targeted embolization.
FAST
EFFECTIVE
& EASY
Filler Cyanoacrylate-Based Embolization Agent stands out as a cutting-edge solution for targeted and rapid vascular occlusion. Its high-viscosity liquid form, comprised of cyanoacrylate, is expertly designed to ensure controlled application and immediate results.
Upon contact with ionic substances such as blood, Filler rapidly polymerizes, leading to instant and durable vessel occlusion. This makes it an ideal choice for critical applications such as arteriovenous malformations, gastrointestinal bleeding, and pre-surgical embolization. Its delivery through standard catheters ensures precise application, reducing the risk of non-target embolization and enhancing procedural success.

- Neuro Aneurysms and AVMs
- Abdominal Aneurysms, Endoleaks
- Neurovascular & Peripheral Aneurysms and AVMs
- Short procedure procedure time.
- Mix with lipiodol for radiopacity
Filler is delivered through a microcatheter into the AVM under fluoroscopic control.
Filler immediately forms a skin as the polymeric embolus solidifies from the outside to the inside, while traveling more distally in the vessel.
Type 2 endoleak from lumbar arteries. (A) Computed tomography (CT) scan in the procubitus position shows posterior opacification of the periprosthetic aneurysmal sac (nidus). (B) Embolization of the endoleak center with a microcatheter under CT guidance until nidus opacification is complete.
제품 사양
사양 | 세부 정보 / 값 |
제품 이름 | Filler Cyanoacrylate Embolization Agent |
사용 목적 | Embolization of AVMs, fistulas, varices, or other lesions requiring permanent vascular occlusion |
Composition | n-Butyl or n-Hexyl cyanoacrylate formulation, polymerizes rapidly upon contact with blood/tissue |
Polymerization Mechanism | Instant polymerization triggered by ionic/aqueous environment |
Delivery Method | Via microcatheter (coaxial with DMSO or compatible flushing agent, if needed) |
방사 불투명도 | May require added radiopaque contrast (e.g., Lipiodol) for fluoroscopic visibility |
Viscosity | Low to medium (check final specs), allowing controlled injection time |
무균 | 멸균, 일회용 |
유통 기한 | 밀봉된 포장 상태로 15-25°C에서 ~2-3년 사용 가능 |
임상 적응증 | Neurovascular or peripheral AVM occlusion, gastrointestinal bleeders, variceal management, certain tumor devascularizations |
금기 사항 | Vessel lumens too small for catheter access, potential risk if accidental nontarget injection, known allergy to cyanoacrylates |
주문 및 사이즈 매트릭스
Cyanoacrylate Concentration (%) | Vial Volume (mL) | Recommended Mixing Ratio | 제품 코드 | 참고 |
33 | 1.0 | 1:1 with radiopaque agent | FIL-33-1.0-1:1 | Lower concentration, slower polymerization, suitable for distal lesions |
33 | 2.0 | 1:1 | FIL-33-2.0-1:1 | Larger vial, same concentration |
50 | 1.0 | 1:0.5 | FIL-50-1.0-1:0.5 | Faster set time, moderate volume |
50 | 2.0 | 1:0.5 | FIL-50-2.0-1:0.5 | Larger volume for multiple feeders |
67 | 1.0 | 1:0.25 | FIL-67-1.0-1:0.25 | High concentration, rapid polymerization for high-flow lesions |
67 | 2.0 | 1:0.25 | FIL-67-2.0-1:0.25 | Maximum control in large or complex AVMs |
연관 상품
-
Libro 비접착성 색전제: EVOH, DMSO 및 탄탈륨
더 보기A 비접착식 EVOH, DMSO, 탄탈륨을 결합한 액체 색전 시스템으로 제어 의 탈혈관화 AVM 또는 종양 공급 용기에 영구적으로 부착되지 않고 정밀한 배치를 보장합니다.
-
Spider™ 두개강 내 코일 시스템(탈착식 푸시형)
더 보기A 탈착식 코일 시스템 에 대한 두개 내 또는 주변기기 동맥류 코일링, 즉각적인 기계적 분리 및 최적화 볼륨 패킹.
-
SteerCATH 조종 가능한 카테터
더 보기A 조종 가능 지원 카테터 편향 가능 팁, 복잡하거나 분기 용기 관상동맥 및 말초 중재술에서 접근성을 높입니다. 까다로운 해부학적 구조에서 교차 성공률을 높입니다.
-
Pars 탈착식 색전술 카테터
더 보기A 카테터 시스템 활성화 선택적 마이크로 카테터 발전 및 기계 또는 화학 색전술, 원위부 분리형 카테터 끼임 방지를 위한 팁을 확인하세요.