Mantis Sistema di trombectomia rotazionale farmacomeccanica CURVE Over-the-Wire (OTW)
Un via cavo (OTW) fusione di dispositivi rotazionale interruzione con farmacologico lisi, eliminando efficacemente i trombi di grandi dimensioni e proteggendo le pareti sane dei vasi.
Rotational Pharmacomechanical Thrombectomy
- Venturi Effect Mechanism: As the active tip spins within the vessel lumen, a hydrodynamic vortex forms, enabling targeted fragmentation and aspiration of the thrombus.
- Drug Infusion Port: Concurrent infusion of anti-thrombolytic agents ensures cohesive mixing with the thrombus, expediting clot dissolution and clearance.
Active Tip with Coil & Sinusoidal Wave
- Coil Design: The sinusoidal wave geometry, visible from the distal tip to proximal region, efficiently engages and fragments clot.
- Preventing Distal Embolism: The rotational vortex action, combined with controlled drug release, helps retain clot particles in proximity for prompt removal, reducing the risk of distal migration.
Over-the-Wire (OTW) Catheter System
- 0.035” Guidewire Compatibility: Simplifies wire management in complex anatomies (including tortuous or large-diameter vessels).
- Catheter Lengths: With 90 cm and 110 cm functional lengths, and 120 cm or 135 cm profiles, the system accommodates an array of procedural approaches.
Multiple Catheter Profiles & Radiopacity
- 5.0F to 8.0F: Offers suitable sizing for broad vessel diameters in the peripheral venous circulation, pulmonary artery, or IVC.
- Radiopaque: The braided shaft is visible under fluoroscopy from distal tip to proximal segment, aiding real-time device positioning.
Rivestimento interno in PTFE
- Low-Friction Catheter Lumen: Streamlines guidewire passage and drug infusion, helping avoid clot or tissue adherence to the catheter walls.
- Reduced Shear Stress: Minimizes friction on vessel endothelium, supporting safer navigation in high-stakes procedures.
Specifiche del prodotto
| Specifiche | Dettaglio / Valore |
| Nome del prodotto | Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System |
| Uso previsto | Combined mechanical disruption + lytic infusion for acute/subacute thrombosis in peripheral or venous systems |
| Design del catetere | Over-the-wire shaft with curved rotational tip for enhanced clot contact, integrated infusion port |
| Rotational Speed Range | ~40k–80k rpm (verify final) |
| Infusion Mechanism | Side port or multi-hole segment for tPA or lytic agent delivery |
| Diametro esterno (F) | ~5–7F, depending on model |
| Lunghezza di lavoro | ~80–120 cm (varies by product code) |
| Compatibilità dei fili guida | Typically 0.035” (OTW approach) |
| Sterilità | Sterile, monouso |
| Durata di conservazione | ~2-3 anni a 15-25 °C in confezione sigillata |
| Indicazioni cliniche | Deep venous thrombosis (DVT), acute peripheral arterial occlusions, possibly for pulmonary thrombosis (per label) |
| Controindicazioni | Extremely tortuous vessels, heavy calcification, or known device material allergies |
Matrice di ordinazione e dimensioni
| Diametro esterno (F) | Lunghezza di lavoro (cm) | Curve Tip Configuration | Codice prodotto | Note |
| 5F | 80 | Moderate Curve | MNT-CV-5F-80-MC | Smaller lumen, shorter approach |
| 5F | 100 | Deep Curve | MNT-CV-5F-100-DC | Extended shaft, deeper curve for better clot contact |
| 6F | 80 | Moderate Curve | MNT-CV-6F-80-MC | Common size for peripheral thrombectomy |
| 6F | 120 | Deep Curve | MNT-CV-6F-120-DC | Extended length with advanced curve tip |
| 7F | 100 | Moderate Curve | MNT-CV-7F-100-MC | Larger lumen for heavier clot burden |
| 7F | 120 | Deep Curve | MNT-CV-7F-120-DC | Max length, enhanced curve for extensive occlusions |
Prodotti correlati
-

AngioHAND Catetere per la rimozione del coagulo
Leggi tuttoA manipolato a mano dispositivo di aspirazione meccanica che consente un'immediata Estrazione del coagulo attraverso un manuale approccio a vuoto, semplificando le procedure di trombectomia acuta.
-

Viper Catetere per trombolisi ULTRA
Leggi tuttoUn ultra catetere per infusione specializzato per diretto somministrazione di trombolitici, con multiforo per distribuire uniformemente i farmaci su ampi segmenti di coagulo.
-

Catetere per palloncino PTCA a rilascio di farmaco Extender Paclitaxel
Leggi tuttoA rivestito di paclitaxel catetere a palloncino coronarico mirato a riduzione della restenosi durante l'angioplastica coronarica percutanea transluminale (PTCA), garantendo un'efficace somministrazione del farmaco alla parete del vaso.
-

Inca Sistema di trombolisi Trellis
Leggi tuttoA catetere consegna trombolitico agenti mentre filtro La protezione impedisce l'embolizzazione distale, garantendo una dissoluzione farmacologica più sicura dei coaguli.