Mantis Sistema di trombectomia rotazionale farmacomeccanica CURVE Over-the-Wire (OTW)
Un via cavo (OTW) fusione di dispositivi rotazionale interruzione con farmacologico lisi, eliminando efficacemente i trombi di grandi dimensioni e proteggendo le pareti sane dei vasi.
Rotational Pharmacomechanical Thrombectomy
- Venturi Effect Mechanism: As the active tip spins within the vessel lumen, a hydrodynamic vortex forms, enabling targeted fragmentation and aspiration of the thrombus.
- Drug Infusion Port: Concurrent infusion of anti-thrombolytic agents ensures cohesive mixing with the thrombus, expediting clot dissolution and clearance.
Active Tip with Coil & Sinusoidal Wave
- Coil Design: The sinusoidal wave geometry, visible from the distal tip to proximal region, efficiently engages and fragments clot.
- Preventing Distal Embolism: The rotational vortex action, combined with controlled drug release, helps retain clot particles in proximity for prompt removal, reducing the risk of distal migration.
Over-the-Wire (OTW) Catheter System
- 0.035” Guidewire Compatibility: Simplifies wire management in complex anatomies (including tortuous or large-diameter vessels).
- Catheter Lengths: With 90 cm and 110 cm functional lengths, and 120 cm or 135 cm profiles, the system accommodates an array of procedural approaches.
Multiple Catheter Profiles & Radiopacity
- 5.0F to 8.0F: Offers suitable sizing for broad vessel diameters in the peripheral venous circulation, pulmonary artery, or IVC.
- Radiopaque: The braided shaft is visible under fluoroscopy from distal tip to proximal segment, aiding real-time device positioning.
Rivestimento interno in PTFE
- Low-Friction Catheter Lumen: Streamlines guidewire passage and drug infusion, helping avoid clot or tissue adherence to the catheter walls.
- Reduced Shear Stress: Minimizes friction on vessel endothelium, supporting safer navigation in high-stakes procedures.
Specifiche del prodotto
Specifiche | Dettaglio / Valore |
Nome del prodotto | Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System |
Uso previsto | Combined mechanical disruption + lytic infusion for acute/subacute thrombosis in peripheral or venous systems |
Design del catetere | Over-the-wire shaft with curved rotational tip for enhanced clot contact, integrated infusion port |
Rotational Speed Range | ~40k–80k rpm (verify final) |
Infusion Mechanism | Side port or multi-hole segment for tPA or lytic agent delivery |
Diametro esterno (F) | ~5–7F, depending on model |
Lunghezza di lavoro | ~80–120 cm (varies by product code) |
Compatibilità dei fili guida | Typically 0.035” (OTW approach) |
Sterilità | Sterile, monouso |
Durata di conservazione | ~2-3 anni a 15-25 °C in confezione sigillata |
Indicazioni cliniche | Deep venous thrombosis (DVT), acute peripheral arterial occlusions, possibly for pulmonary thrombosis (per label) |
Controindicazioni | Extremely tortuous vessels, heavy calcification, or known device material allergies |
Matrice di ordinazione e dimensioni
Diametro esterno (F) | Lunghezza di lavoro (cm) | Curve Tip Configuration | Codice prodotto | Note |
5F | 80 | Moderate Curve | MNT-CV-5F-80-MC | Smaller lumen, shorter approach |
5F | 100 | Deep Curve | MNT-CV-5F-100-DC | Extended shaft, deeper curve for better clot contact |
6F | 80 | Moderate Curve | MNT-CV-6F-80-MC | Common size for peripheral thrombectomy |
6F | 120 | Deep Curve | MNT-CV-6F-120-DC | Extended length with advanced curve tip |
7F | 100 | Moderate Curve | MNT-CV-7F-100-MC | Larger lumen for heavier clot burden |
7F | 120 | Deep Curve | MNT-CV-7F-120-DC | Max length, enhanced curve for extensive occlusions |
Prodotti correlati
-
Catetere con palloncino PTCA Extender
Leggi tuttoA standard alta pressione palloncino coronarico progettato per predilazione della lesione o indipendente angioplasticache offre profili di gonfiaggio precisi e profili di attraversamento ridotti.
-
Catetere per palloncino PTCA a rilascio di farmaco Extender Paclitaxel
Leggi tuttoA rivestito di paclitaxel catetere a palloncino coronarico mirato a riduzione della restenosi durante l'angioplastica coronarica percutanea transluminale (PTCA), garantendo un'efficace somministrazione del farmaco alla parete del vaso.
-
MultiBEAM Filtro per la vena cava inferiore (IVC)
Leggi tuttoUn'opzione convertibile o recuperabile Prevenzione del filtro IVC emboli polmonari intercettando i coaguli che viaggiano attraverso la vena cava inferiore, garantendo la sicurezza nei pazienti ad alto rischio.
-
VeinOFF Agente per il trattamento delle vene varicose
Leggi tuttoUno specialista sclerosante o adesivo formula mirata a non termico eliminazione delle vene varicose, che richiede un'anestesia minima e tempi di intervento brevi.