AngioHAND Catetere per la rimozione del coagulo
A manipolato a mano dispositivo di aspirazione meccanica che consente un'immediata Estrazione del coagulo attraverso un manuale approccio a vuoto, semplificando le procedure di trombectomia acuta.
The AngioHAND Clot Removal Catheter by Invamed is a hand-operated mechanical aspiration system designed to immediately remove thrombi or emboli during acute vascular occlusions. Featuring braided balloon-shaped structures, the catheter actively captures clots and pulls them into the lumen, enabling safe, streamlined thrombectomy without complex capital equipment or continuous vacuum lines. Ideal for distal or proximal arterial/venous clots, AngioHAND simplifies acute stroke, limb ischemia, or DVT management.
Braided Balloon-Shaped Capture
- Expandable mesh or braided balloon segments at the distal tip engage and enclose clot mass, guiding it into the catheter lumen.
- Ensures robust clot entrapment without excessive fragmentation or distal embolization.
Manual Vacuum Mechanism
- Operated by a hand-held syringe-like device or integrated handle, creating a controlled negative pressure to aspirate clot into the catheter shaft.
- Minimizes procedural complexity—no large vacuum pumps—offering immediate aspiration capacity at the bedside or in urgent OR settings.
Rapid & Intuitive Thrombectomy
- Inserted percutaneously via a small arterial or venous access; navigated under fluoroscopic guidance to the occlusion site.
- One-hand manipulation of the aspiration handle triggers vacuum and clot removal in real-time, optimizing speed and efficiency.
Enhanced Safety & Vessel Protection
- Balloon-shaped braids gently expand against the vessel walls, preventing the catheter tip from causing undue trauma.
- Reduces the risk of iatrogenic injuries and maintains patency around the extraction zone for improved patient outcomes.
Multiple Clinical Indications
- Acute ischemic stroke retrieval in cerebral arteries (depending on vessel diameter and regulatory approvals).
- Peripheral arterial occlusions (e.g., acute limb ischemia, popliteal thrombosis) or venous thrombi (DVT).
- Use in emergent or elective procedures where fast mechanical clot extraction is paramount.
Specifiche del prodotto
| Specifiche | Dettaglio / Valore |
| Nome del prodotto | AngioHAND Catetere per la rimozione del coagulo |
| Uso previsto | Manual vacuum-based aspiration of thrombus, emboli, or clot debris in peripheral or coronary vessels |
| Design del catetere | Hand-operated syringe or vacuum-based system, flexible polymer shaft with a soft distal tip |
| Gamma del diametro esterno | ~5F–7F (depending on model) |
| Lumen Inner Diameter | Large bore optimized for clot aspiration |
| Lunghezza di lavoro | ~80–120 cm (varies by product code) |
| Configurazione dei suggerimenti | Tapered or funnel-shaped tip to facilitate clot ingress |
| Radiopaque Marker | Distal marker band for fluoroscopic location |
| Vacuum Mechanism | Manual hand-syringe or integrated vacuum lock (no external pump required) |
| Sterilità | Sterile, monouso |
| Durata di conservazione | ~2–3 years at 15–25 °C |
| Indicazioni cliniche | Acute clot removal in peripheral arteries/veins, smaller coronary vessels, or bypass grafts |
| Controindicazioni | Severe vessel tortuosity, extremely large clot burden exceeding device capacity, known device material allergy |
Matrice di ordinazione e dimensioni
| Diametro esterno (F) | Lunghezza di lavoro (cm) | Tip Style | Codice prodotto | Note |
| 5F | 80 | Tapered Soft Tip | ANG-HND-5F-80-TS | Smaller diameter for coronary or distal peripheral |
| 5F | 100 | Funnel Tip | ANG-HND-5F-100-FN | Moderate length, manual vacuum approach |
| 6F | 80 | Tapered Soft Tip | ANG-HND-6F-80-TS | Common size for peripheral thrombus aspiration |
| 6F | 120 | Funnel Tip | ANG-HND-6F-120-FN | Extended length for deeper occlusion sites |
| 7F | 100 | Tapered Soft Tip | ANG-HND-7F-100-TS | Larger lumen for heavier clot burden |
| 7F | 120 | Funnel Tip | ANG-HND-7F-120-FN | Maximum length plus funnel design for wide clot removal |
Prodotti correlati
-

Dovi Catetere per l'aspirazione del trombo Ultra
Leggi tuttoA alto vuoto catetere di aspirazione per acuto o subacuto rimozione del trombo nei letti arteriosi o venosi, garantendo una rapida rivascolarizzazione con un rischio minimo di frammentazione.
-

Inca Sistema di trombolisi Trellis
Leggi tuttoA catetere consegna trombolitico agenti mentre filtro La protezione impedisce l'embolizzazione distale, garantendo una dissoluzione farmacologica più sicura dei coaguli.
-

Sistema laser per vene varicose LaserBLOCK
Leggi tuttoUn endovenoso set di laserterapia per varicose vene, imbrigliamento mirato energia laser per sigillare termicamente le vene incompetenti, consentendo un rapido ritorno all'attività quotidiana.
-

Sistema di protezione contro le embolie Inca
Leggi tuttoA catetere consegna trombolitico agenti mentre filtro La protezione impedisce l'embolizzazione distale, garantendo una dissoluzione farmacologica più sicura dei coaguli.