Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration
A rotationnel qui comprend un système de pointe de la feuille conception pour mécanique fragmentation du caillot plus fort des capacités d'aspiration dans les occlusions veineuses ou artérielles profondes.
Le Mantis Rotational Thrombectomy System is an advanced catheter-based device engineered to disrupt and remove thrombus from peripheral and/or central vasculature. Utilizing a leaf tip design and a Nitinol shaft reinforced with PA/PEBAX polymers, the Mantis system delivers a high-torque, low-profile solution for physicians aiming to restore flow in acute, subacute, or chronic thrombotic occlusions.
Leaf Tip Design
- The proprietary leaf tip shape allows precise clot engagement and fragmentation, enhancing device efficiency in complex or large-burden thrombotic lesions.
- Distal Infusion Zone: Positioned between the leaf tip and the catheter’s distal end, enabling targeted delivery of thrombolytic agents or contrast media when required.
Nitinol Shaft with PA/PEBAX
- High Torque Response: Nitinol’s superelastic properties provide excellent pushability, kink resistance, and precise rotational control, even in tortuous anatomies.
- Composite Construction: The PA/PEBAX polymer layers offer a smooth lumen and robust structural support, minimizing friction while improving durability.
Radiopaque Shaft Markings
- Nitinol Wire Visibility: Clear radiopacity from the distal tip to the proximal shaft allows real-time, precise imaging under fluoroscopy.
- Facilite accurate positioning and ensures confident navigation through complex vascular pathways.
Flexible Catheter Profiles
- Available in 5.0F and 6.0F to accommodate varying vessel diameters and flow requirements.
- Active Zone: Ranges from 5 mm to 60 mm, enabling versatile clot engagement depths and optimal coverage in different occlusion lengths.
Multiple Catheter Lengths
90 cm, 110 cm, and 135 cm options provide adaptability for diverse procedural approaches, from short femoral access to more extended radial or brachial routes.
Spécifications des produits
Spécifications | Détail / Valeur |
Nom du produit | Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration |
Utilisation prévue | Mechanical disruption and aspiration of thrombi or emboli in peripheral and/or venous systems |
Conception du cathéter | Rotational wire with a leaf-shaped tip, integrated aspiration lumen for clot removal |
Matériau | Stainless steel or nitinol drive shaft, flexible polymer outer sheath |
Rotational Speed Range | ~40k–80k rpm (check final specs) |
Aspiration Mechanism | Over-the-wire suction or integrated vacuum line |
Catheter Outer Diameter | ~5–7F, depending on model and tip size |
Longueur de travail | ~80-120 cm (varie selon le code produit) |
Radiopacité | Distal marker near leaf tip for precise positioning under fluoroscopy |
Stérilité | Stérile, à usage unique |
Durée de conservation | ~2-3 ans à 15-25 °C |
Indications cliniques | Acute or subacute thrombotic occlusions in peripheral arteries/veins, possibly deep venous thrombosis (DVT) |
Contre-indications | Extremely tortuous vessels, heavily calcified lesions, or known intolerance to device materials |
Commande et matrice des tailles
Diamètre extérieur (F) | Longueur de travail (cm) | Leaf Tip Diameter (mm) | Code produit | Notes |
5F | 80 | 5 | MNT-LF-5F-80-5 | Smaller tip for distal or smaller vessels |
5F | 100 | 5 | MNT-LF-5F-100-5 | Longer shaft, same leaf diameter |
6F | 80 | 6 | MNT-LF-6F-80-6 | Common size for peripheral artery usage |
6F | 120 | 6 | MNT-LF-6F-120-6 | Extended length for deeper or proximal segments |
7F | 100 | 7 | MNT-LF-7F-100-7 | Larger leaf tip for heavier thrombus loads |
7F | 120 | 7 | MNT-LF-7F-120-7 | Max length and larger tip for extensive clot burden |
Produits similaires
-
VenoNeedle® Système d'ablation par radiofréquence des petites veines
Lire la suiteA faible consommation système thermique visant à veines en araignéeLes varices réticulaires de petite taille, les télangiectasies ou les petites varices réticulaires avec précis coagulation, évitant ainsi les grandes incisions ou les temps d'arrêt prolongés.
-
Viper Cathéter de thrombolyse ULTRA
Lire la suiteUn ultra cathéter de perfusion spécialisé pour direct l'administration de thrombolytiques, avec multi-trous de distribuer uniformément les médicaments dans de vastes segments de coagulation.
-
Dovi Cathéter d'aspiration Thrombus Ultra
Lire la suiteA vide poussé cathéter d'aspiration pour aiguës ou subaiguë l'élimination des thrombus dans les lits artériels ou veineux, assurant une revascularisation rapide avec un risque minimal de fragmentation.
-
ICT Thérapie par compression interne
Lire la suiteICT Système de reconstruction par colmatage de fuites valvulaires
ICT est une thérapie par compression interne pour les valves veineuses dysfonctionnelles. La procédure est également appelée valvuloplastie percutanée.