Mantis CURVE Système de thrombectomie rotationnelle pharmacomécanique par fil (OTW)
Un par câble (OTW) fusion de dispositifs rotationnel perturbation avec pharmacologique La lyse des thrombus, en éliminant efficacement les gros thrombus tout en protégeant les parois saines des vaisseaux.
Rotational Pharmacomechanical Thrombectomy
- Venturi Effect Mechanism: As the active tip spins within the vessel lumen, a hydrodynamic vortex forms, enabling targeted fragmentation and aspiration of the thrombus.
- Drug Infusion Port: Concurrent infusion of anti-thrombolytic agents ensures cohesive mixing with the thrombus, expediting clot dissolution and clearance.
Active Tip with Coil & Sinusoidal Wave
- Coil Design: The sinusoidal wave geometry, visible from the distal tip to proximal region, efficiently engages and fragments clot.
- Preventing Distal Embolism: The rotational vortex action, combined with controlled drug release, helps retain clot particles in proximity for prompt removal, reducing the risk of distal migration.
Over-the-Wire (OTW) Catheter System
- 0.035” Guidewire Compatibility: Simplifies wire management in complex anatomies (including tortuous or large-diameter vessels).
- Catheter Lengths: With 90 cm and 110 cm functional lengths, and 120 cm or 135 cm profiles, the system accommodates an array of procedural approaches.
Multiple Catheter Profiles & Radiopacity
- 5.0F to 8.0F: Offers suitable sizing for broad vessel diameters in the peripheral venous circulation, pulmonary artery, or IVC.
- Radiopaque: The braided shaft is visible under fluoroscopy from distal tip to proximal segment, aiding real-time device positioning.
Revêtement intérieur en PTFE
- Low-Friction Catheter Lumen: Streamlines guidewire passage and drug infusion, helping avoid clot or tissue adherence to the catheter walls.
- Reduced Shear Stress: Minimizes friction on vessel endothelium, supporting safer navigation in high-stakes procedures.
Spécifications des produits
Spécifications | Détail / Valeur |
Nom du produit | Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System |
Utilisation prévue | Combined mechanical disruption + lytic infusion for acute/subacute thrombosis in peripheral or venous systems |
Conception du cathéter | Over-the-wire shaft with curved rotational tip for enhanced clot contact, integrated infusion port |
Rotational Speed Range | ~40k–80k rpm (verify final) |
Infusion Mechanism | Side port or multi-hole segment for tPA or lytic agent delivery |
Diamètre extérieur (F) | ~5–7F, depending on model |
Longueur de travail | ~80-120 cm (varie selon le code produit) |
Compatibilité des fils-guides | Typically 0.035” (OTW approach) |
Stérilité | Stérile, à usage unique |
Durée de conservation | ~2-3 ans à 15-25 °C dans un emballage scellé |
Indications cliniques | Deep venous thrombosis (DVT), acute peripheral arterial occlusions, possibly for pulmonary thrombosis (per label) |
Contre-indications | Extremely tortuous vessels, heavy calcification, or known device material allergies |
Commande et matrice des tailles
Diamètre extérieur (F) | Longueur de travail (cm) | Curve Tip Configuration | Code produit | Notes |
5F | 80 | Moderate Curve | MNT-CV-5F-80-MC | Smaller lumen, shorter approach |
5F | 100 | Deep Curve | MNT-CV-5F-100-DC | Extended shaft, deeper curve for better clot contact |
6F | 80 | Moderate Curve | MNT-CV-6F-80-MC | Common size for peripheral thrombectomy |
6F | 120 | Deep Curve | MNT-CV-6F-120-DC | Extended length with advanced curve tip |
7F | 100 | Moderate Curve | MNT-CV-7F-100-MC | Lumière plus large pour une charge de caillots plus importante |
7F | 120 | Deep Curve | MNT-CV-7F-120-DC | Max length, enhanced curve for extensive occlusions |
Produits similaires
-
Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration
Lire la suiteA rotationnel qui comprend un système de pointe de la feuille conception pour mécanique fragmentation du caillot plus fort des capacités d'aspiration dans les occlusions veineuses ou artérielles profondes.
-
LaserBLOCK Système laser pour les veines variqueuses
Lire la suiteUn endoveineux thérapie au laser pour varice veines, harnachement ciblée L'énergie laser est utilisée pour sceller thermiquement les veines incompétentes, ce qui permet un retour rapide à l'activité quotidienne.
-
Viper Cathéter de thrombolyse ULTRA
Lire la suiteUn ultra cathéter de perfusion spécialisé pour direct l'administration de thrombolytiques, avec multi-trous de distribuer uniformément les médicaments dans de vastes segments de coagulation.
-
Inca Système de thrombolyse Trellis
Lire la suiteA cathéter livrer thrombolytique agents tandis que filtre empêche l'embolisation distale, garantissant une dissolution pharmacologique plus sûre des caillots.