InWIRE NEURO Fil guide neurovasculaire
Neuro-spécifique fils-guides offre couple réponse et flexible pour naviguer dans les vaisseaux intracrâniens et faciliter la mise en place de bobines ou d'endoprothèses dans les anévrismes complexes.
Navigate with Confidence: Choose Inwire
- Enhanced Navigation: Smoothly navigate through complex vascular structures.
- Precision Control: Exceptional torque control for accurate placement.
- Smooth Operation: Hydrophilic coating for ease of use.
- Precision Control: Exceptional torque control for accurate placement.
Inwire: Your Partner in Precision for Neurovascular Procedures
- Reliable Construction: Made from high-quality materials for dependable performance.
- Versatile Sizing: Available in various diameters and lengths to suit your needs.
- Patient Safety: Atraumatic tip design to minimize risk.
- Versatile Sizing: Available in various diameters and lengths to suit your needs.
- Flexibility: Designed to navigate through complex vascular structures.
- Control: Provides exceptional torque control for precise navigation.
- Coating: Hydrophilic coating ensures smooth passage through vessels.
- Material: Constructed from high-quality materials for reliability.
- Diameter and Length: Available in various sizes to accommodate different procedures.
- Tip: Atraumatic tip design to minimize risk of vessel damage.
- Control: Provides exceptional torque control for precise navigation.

The Inwire Neurovascular Guide Wire is a state-of-the-art tool designed for precision and control in neurovascular procedures. Its exceptional flexibility and torque control allow for seamless navigation through the most complex of vascular structures.
Coated with a hydrophilic material, the Inwire Guide Wire glides smoothly through vessels, minimizing resistance and enhancing the overall procedure. The high-quality construction ensures reliability and durability, even in the most demanding situations.
Available in various diameters and lengths, the Inwire Guide Wire can be tailored to suit a wide range of neurovascular procedures, ensuring that you have the right tool for the job at hand. The atraumatic tip design further ensures patient safety, minimizing the risk of vessel damage during navigation.

Polymer Jacket 150cm
& Hydrophilic 170cm
Tip Radioopacity
5cm
Re-Shapeable
Round Curve Tip
Outer Diameter
0.014" to 0.018"
Usable Length
200cm to 300cm
0.010" (0.26mm)
Polymer Jacket 150cm
& Hydrophilic 170cm
Tip Radioopacity
5cm
Usable Length
170cm to 300cm
Outer Diameter
0.008" to 0.012"
0.008" (0.20mm)
Round Curve Tip
High Progressability
- Durable Performance: The guidewires maintain consistent push and torque capabilities in challenging anatomies, facilitating confident access to the target lesion.
- Superior Lesion Crossing: Advanced core composition and tapered design reduce friction, supporting stable navigation through calcified or tortuous vessels.
Steerability and Torque Control
- Easy Steering: A carefully engineered wire shaft and distal tapering structure ensure accurate tip response and predictable turn movements.
- Torque Capability: Delivers precise rotational transmission from the handle to the distal tip, crucial for tight or angled pathways in neurovascular and peripheral arteries.
Flat, Malleable Distal Tip
- Custom Tip Shaping: The distal wire tip can be easily bent or contoured to accommodate difficult lesion angles, especially relevant in neurovascular procedures.
- Radiopaque Distal Segment (2–3 cm): Enables real-time fluoroscopic tracking of the tip position during device navigation and lesion crossing.
Revêtement polymère hydrophile
- Low-Friction Advancement: Reduces vessel wall adhesion, promoting safer crossing in intricate or long-segment lesions.
- Improved Navigability: Diminishes the risk of wire entrapment or microcatheter “kick-back,” especially when maneuvering through acute vessel curves.
Diameter Options and Lengths
- Diameter Range: 0.010”, 0.012”, 0.014”, 0.018”—catering to neurovascular microcatheter systems and peripheral interventions.
- Multiple Lengths: Diverse wire lengths for short-segment access or extended vessel coverage, enabling personalized approach based on the lesion site and patient anatomy
Spécifications des produits
Spécifications | Détail / Valeur |
Nom du produit | InWIRE NEURO Fil guide neurovasculaire |
Utilisation prévue | Guidewire assistance in neurovascular interventions (aneurysm coiling, AVM embolization, intracranial stenting) |
Matériau de base | Stainless steel or nitinol core for torque stability |
Revêtement | Hydrophilic or hybrid (distal hydrophilic, proximal hydrophobic) |
Style de l'extrémité distale | Floppy or intermediate tip load, radiopaque coil segment for visibility |
Diamètre nominal | 0.010”, 0.012”, or 0.014” (depending on model) |
Gamme de longueur totale | ~160–300 cm (varies by product code) |
Tip Load Category | ~1–3 g (floppy), ~4–6 g (intermediate) |
Radiopacité | Distal 2–3 cm platinum coil or tungsten marking |
Stérilité | Stérile, à usage unique |
Durée de conservation | ~2-3 ans à 15-25 °C dans un emballage scellé |
Indications cliniques | Intracranial lesion navigation, microcatheter support, complex neurovascular anatomies |
Contre-indications | Extremely narrow or tortuous vessels preventing wire passage, known device material allergy |
Commande et matrice des tailles
Wire Diameter (inch) | Overall Length (cm) | Style de pointe | Revêtement | Code produit | Notes |
0.010” | 160 | Disquette | Hydrophile | INW-N-0.010-160-F-H | Ultra-thin wire for distal microanatomies |
0.010” | 200 | Intermédiaire | Hydrophobe | INW-N-0.010-200-I-HB | Slightly stiffer tip, frictionless proximal |
0.012” | 200 | Disquette | Hybride | INW-N-0.012-200-F-Hy | Partial hydro distal, standard proximal |
0.012” | 260 | Intermédiaire | Hydrophile | INW-N-0.012-260-I-H | Extended length for deeper intracranial lesions |
0.014" | 300 | Disquette | Hydrophile | INW-N-0.014-300-F-H | Longest wire, minimal tip load for complex coil navigation |
Produits similaires
-
Extender Cathéter à ballonnet PTCA à élution médicamenteuse Paclitaxel
Lire la suiteA recouvert de paclitaxel cathéter coronaire à ballonnet destiné à réduire la resténose pendant l'angioplastie coronaire transluminale percutanée (ACTP), garantissant ainsi l'administration efficace du médicament à la paroi du vaisseau.
-
Atlas Système d'endoprothèse coronaire Acier inoxydable
Lire la suiteA acier inoxydable offre d'endoprothèses coronaires robuste l'intégrité structurelle et facile pour les interventions coronariennes percutanées (ICP) de routine, en conciliant rentabilité et fiabilité des performances.
-
TemREN Rotablator
Lire la suiteA rotationnel système de thrombectomie ou d'athérectomie comprenant à grande vitesse bavures à broyage ou retirer la plaque calcifiée, assurant ainsi une meilleure expansion de la lumière pour la mise en place du stent.
-
Libro Agent d'embolisation non adhésif : EVOH, DMSO et Tantale
Lire la suiteA non adhésif système embolique liquide combinant EVOH, DMSO et tantale pour le traitement de l'hypertension. contrôlé dévascularisation de MAV ou tumeur Les dispositifs d'alimentation en oxygène peuvent être utilisés dans les vaisseaux d'alimentation, ce qui garantit un déploiement précis sans adhérence permanente aux vaisseaux.