Stena Modulador de flujo multicapa intracraneal

A multicapa construcción de desviación de flujo para aneurismas intracranealesredirigiendo el flujo sanguíneo fuera del saco del aneurisma y manteniendo al mismo tiempo la perfusión esencial de las ramas.

En Stent Neurovascular Multilayer Flow Modulator es un multi-layer, self-expandable implant designed to redirect blood flow across intracranial aneurysms or pseudoaneurysms (saccular, fusiform, or dissection). Constructed from nitinol braided wires, this flow-guided device harnesses hemodynamic modulation to promote stable aneurysm occlusion while preserving key vessel branches.

Multi-Layer Braided Nitinol Wires
  • Self-Expanding Implant: Adapts seamlessly to the host vessel, delivering gentle but consistent radial support.
  • Optimized Flow Modulation: Braided mesh design disperses hemodynamic forces, encouraging gradual aneurysm thrombosis without aggressively blocking perforator flow.
  • Excellent Visibility: Enhanced radiopacity simplifies device deployment and positioning under fluoroscopic guidance.
  • Continuous Vessel Coverage: The robust structure ensures stable wall apposition, helping minimize device migration or incomplete vessel coverage.
  • Size-Specific Microcatheters: Designed for use with 3.6F or 3.9F microcatheter (outer) and 2.3F internal microcatheter, ensuring preciso navigation and stent delivery.
  • Pre-Loaded Configuration: The stent is supplied pre-loaded on its dedicated delivery system, streamlining procedural workflow and minimizing device manipulation.
  • Percutaneous Arterial Approach: Minimizes invasive exposure by allowing stent introduction through small-caliber femoral or radial arteries.
  • Adaptive Vessel Conformance: The device maintains uniform radial force along irregular or tortuous intracranial segments, preserving branch patency.
  • Self-Expanding Implant: Adapts seamlessly to the host vessel, delivering gentle but consistent radial support.
  • Optimized Flow Modulation: Braided mesh design disperses hemodynamic forces, encouraging gradual aneurysm thrombosis without aggressively blocking perforator flow.
  • Excellent Visibility: Enhanced radiopacity simplifies device deployment and positioning under fluoroscopic guidance.
  • Continuous Vessel Coverage: The robust structure ensures stable wall apposition, helping minimize device migration or incomplete vessel coverage.
  • Size-Specific Microcatheters: Designed for use with 3.6F or 3.9F microcatheter (outer) and 2.3F internal microcatheter, ensuring preciso navigation and stent delivery.
  • Pre-Loaded Configuration: The stent is supplied pre-loaded on its dedicated delivery system, streamlining procedural workflow and minimizing device manipulation.
  • Percutaneous Arterial Approach: Minimizes invasive exposure by allowing stent introduction through small-caliber femoral or radial arteries.
  • Adaptive Vessel Conformance: The device maintains uniform radial force along irregular or tortuous intracranial segments, preserving branch patency.

Especificaciones del producto

Especificación Detalle / Valor
Nombre del producto Stena Modulador de flujo multicapa intracraneal
Uso previsto Endovascular flow diversion for intracranial aneurysms (saccular, fusiform) or complex neurovascular lesions
Diseño Multi-layer braided nitinol mesh stent, self-expanding, designed to modulate blood flow while preserving side branches
Material Medical-grade Nitinol (Nickel-Titanium)
Mecanismo de despliegue Sheath-based retraction or microcatheter system release
Delivery Catheter Compatibility Typically 0.027” or 0.021” ID microcatheter (depending on stent diameter)
Marcadores radiopacos Proximal and distal marker bands for fluoroscopic positioning
Compatibilidad MR MR Conditional (verify labeling)
Esterilidad Estéril, un solo uso
Vida útil ~3–5 years, stored at 15–25 °C in sealed packaging
Indicaciones clínicas Intracranial aneurysms (small or large/giant), dissecting or fusiform aneurysms, flow diversion in distal vessels
Contraindicaciones Extremely tortuous intracranial vessels beyond feasible access, known nickel allergy, insufficient landing zone

Matriz de pedidos y tamaños

Stent Diameter (mm) Stent Length (mm) Microcatheter ID (inch) Código del producto Notas
2.5 12 0.021" STN-IC-2.5x12-021 Smaller diameter, short aneurysm coverage
2.5 18 0.021" STN-IC-2.5x18-021 Extended length for multiple side branches
3.0 18 0.027" STN-IC-3.0x18-027 Common diameter for medium intracranial vessels
3.0 25 0.027" STN-IC-3.0x25-027 Longer stent for extended aneurysm neck
3.5 20 0.027" STN-IC-3.5x20-027 Slightly larger diameter for wide-neck aneurysms
3.5 30 0.027" STN-IC-3.5x30-027 Extended coverage in more proximal segments
4.0 20 0.027" STN-IC-4.0x20-027 Larger diameter for cavernous ICA aneurysms
4.0 30 0.027" STN-IC-4.0x30-027 Extended length for giant aneurysm coverage
4.5 25 0.027" STN-IC-4.5x25-027 XL diameter for large internal carotid segments
4.5 35 0.027" STN-IC-4.5x35-027 Maximum coverage for fusiform or dissecting lesions