Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration

A rotacional system featuring a leaf tip design for mecánico clot fragmentation plus strong aspiration capabilities in deep venous or arterial occlusions.

En Mantis Rotational Thrombectomy System is an advanced catheter-based device engineered to disrupt and remove thrombus from peripheral and/or central vasculature. Utilizing a leaf tip design and a Nitinol shaft reinforced with PA/PEBAX polymers, the Mantis system delivers a high-torque, low-profile solution for physicians aiming to restore flow in acute, subacute, or chronic thrombotic occlusions.

Leaf Tip Design
  • The proprietary leaf tip shape allows precise clot engagement and fragmentation, enhancing device efficiency in complex or large-burden thrombotic lesions.
  • Distal Infusion Zone: Positioned between the leaf tip and the catheter’s distal end, enabling targeted delivery of thrombolytic agents or contrast media when required.
  • High Torque Response: Nitinol’s superelastic properties provide excellent pushability, kink resistance, and precise rotational control, even in tortuous anatomies.
  • Composite Construction: The PA/PEBAX polymer layers offer a smooth lumen and robust structural support, minimizing friction while improving durability.
  • Nitinol Wire Visibility: Clear radiopacity from the distal tip to the proximal shaft allows real-time, precise imaging under fluoroscopy.
  • Facilitates accurate positioning and ensures confident navigation through complex vascular pathways.
  • Disponible en 5.0F and 6.0F to accommodate varying vessel diameters and flow requirements.
  • Active Zone: Ranges from 5 mm to 60 mm, enabling versatile clot engagement depths and optimal coverage in different occlusion lengths.

90 cm, 110 cm, and 135 cm options provide adaptability for diverse procedural approaches, from short femoral access to more extended radial or brachial routes.

Especificaciones del producto

Especificación Detalle / Valor
Nombre del producto Mantis Leaf Tip Rotational Thrombectomy & Ultra Aspiration
Uso previsto Mechanical disruption and aspiration of thrombi or emboli in peripheral and/or venous systems
Diseño del catéter Rotational wire with a leaf-shaped tip, integrated aspiration lumen for clot removal
Material Stainless steel or nitinol drive shaft, flexible polymer outer sheath
Velocidad de rotación ~40k–80k rpm (check final specs)
Aspiration Mechanism Over-the-wire suction or integrated vacuum line
Catheter Outer Diameter ~5–7F, depending on model and tip size
Longitud de trabajo ~80–120 cm (varies by product code)
Radiopacidad Distal marker near leaf tip for precise positioning under fluoroscopy
Esterilidad Estéril, un solo uso
Vida útil ~2–3 years at 15–25 °C
Indicaciones clínicas Acute or subacute thrombotic occlusions in peripheral arteries/veins, possibly deep venous thrombosis (DVT)
Contraindicaciones Extremely tortuous vessels, heavily calcified lesions, or known intolerance to device materials

Matriz de pedidos y tamaños

Diámetro exterior (F) Longitud de trabajo (cm) Leaf Tip Diameter (mm) Código del producto Notas
5F 80 5 MNT-LF-5F-80-5 Smaller tip for distal or smaller vessels
5F 100 5 MNT-LF-5F-100-5 Longer shaft, same leaf diameter
6F 80 6 MNT-LF-6F-80-6 Common size for peripheral artery usage
6F 120 6 MNT-LF-6F-120-6 Extended length for deeper or proximal segments
7F 100 7 MNT-LF-7F-100-7 Larger leaf tip for heavier thrombus loads
7F 120 7 MNT-LF-7F-120-7 Max length and larger tip for extensive clot burden