Horus® Optic Laser Probes (Photocoagulation)
A titanio o aleación sistema de placa esternal que proporciona rígido fijación tras la esternotomía media, mejorando estabilidad esternal y reducir los riesgos de infección o dehiscencia tras la cirugía cardíaca.
En Horus® Optic Laser Probes by Invamed deliver high-performance photocoagulation capabilities for vitreoretinal surgery and other ophthalmic interventions. Constructed from medical-grade fiber optics, these probes offer precise laser energy transmission to the retina or posterior segment, ensuring effective photocoagulation with minimal scatter. Available in 20, 23, 25, or 27 gauge (0.81 mm, 0.64 mm, 0.50 mm, 0.41 mm), each probe caters to diverse procedural preferences and ocular anatomies.
Wide Range of Gauge Sizes
- 20G (0.81 mm), 23G (0.64 mm), 25G (0.50 mm), 27G (0.41 mm): Broad selection accommodates various surgical approaches—from standard vitrectomy ports to ultra-fine, minimally invasive surgeries.
- Surgeons can select the optimal gauge for patient-specific anatomy, pathology, and lens clarity.
High-Purity Fiber Optic Construction
- Fiber cables are derived from medical-grade fused silica or equivalent high-quality materials, ensuring superior light transmission and minimal dispersion.
- Enhanced photocoagulation precision reduces collateral tissue damage, crucial in delicate retinal structures.
Sterile & Disposable
- Probes come sterile and single-use, preventing cross-contamination and maintaining consistent optical performance.
- Simplifies OR workflow and eliminates the need for repeated reprocessing, reducing risk of fiber damage over multiple sterilization cycles.
Soft Tip & Angled Variants
- Certain models feature soft tip designs to safeguard against iatrogenic injury during retinal manipulations.
- Angled or curved tip options provide surgeons with improved access to peripheral or posterior pole lesions.
Versatile Laser Compatibility
- Estándar endolaser coupling ensures broad compatibility with common ophthalmic laser systems (e.g., diode, argon).
- Color-coded or labeled connectors enable quick identification and safe, secure attachment during setup.
Indicaciones clínicas
- Retinal photocoagulation for diabetic retinopathy, macular edema, peripheral retina tears, lattice degeneration, or choroidal neovascular membranes.
- Vitreoretinal procedures requiring localized laser application—such as panretinal photocoagulation (PRP) or focal macular treatments.
Productos relacionados
-
Clever Malla parcialmente absorbible
Leer másUna malla quirúrgica ligera combinando durabilidad y materiales absorbibles, diseñado para proporcionar apoyo temporal durante la cicatrización de los tejidos reduciendo al mismo tiempo a largo plazo presencia de cuerpos extraños en procedimientos como como la reparación de hernias.
-
Invaducer Intraductor
Leer másA titanio o aleación sistema de placa esternal que proporciona rígido fijación tras la esternotomía media, mejorando estabilidad esternal y reducir los riesgos de infección o dehiscencia tras la cirugía cardíaca.
-
VitaFLEX Ácido hialurónico intradérmico
Leer másCompuesto por ácido hialurónico de gran pureza, este relleno dérmico biocompatible mejora la hidratación, la elasticidad y el volumen de la piel, minimizando eficazmente las líneas finas y las arrugas para conseguir un aspecto más joven.
-
Peta Mechanical Percutaneous Disk Decompression
Leer másDesigned with precision-engineered materials, this minimally invasive device enables effective decompression of herniated discs, relieving pressure on spinal nerves and alleviating pain while promoting faster recovery.