Bionovus Nefrectomía Catéter de nefrostomía percutánea (Pigtail)
Un catéter pigtail diseñado con precisión y adaptado a la nefrostomía percutánea, que garantiza una colocación segura, un drenaje eficaz y menos molestias para el paciente durante la nefrectomía y procedimientos relacionados.
En Bionovus Nephrectomy Percutaneous Nephrostomy Catheter is an advanced pigtail-style device intended for temporary external drainage in upper ureteral and renal obstructions—particularly those stemming from renal tumors or inflammatory processes. By providing a secure drainage pathway, it helps alleviate pressure buildup, maintain renal function, and reduce patient discomfort. Constructed from soft, biocompatible polyurethane, the catheter is highly radiopaque, offering efficient fluoroscopic guidance and user-friendly insertion.
Biocompatible Soft Polyurethane
- Gentle on Tissues: Flexible, smooth material reduces trauma during placement and long-term indwelling, enhancing patient comfort.
- Durable & Resistant: Maintains structural integrity under continuous drainage conditions.
High Bending Strength
- Secure, Kink-Resistant Drainage: Resilient design prevents catheter collapse in tortuous renal pathways or while navigating challenging anatomical angles.
- Robust Performance: Maintains uninterrupted flow, limiting the risk of catheter occlusion or displacement.
Radiopacity & Depth Scale
- Marked with Radiopaque Bands: Ensures consistent fluoroscopic or ultrasound visibility for precise, real-time positioning.
- Graduated Depth Markings: Facilitates accurate placement in the renal collecting system, reducing repeated repositioning attempts.
Long Pusher Options (40–100 cm)
- Adaptable to Various Patient Profiles: Multiple pusher lengths accommodate deeper or more proximal access routes, supporting diverse procedural needs.
- Ease of Use: Simplifies advancement and stabilization in extended or anatomically complex drainage paths.
Radiopaque Repellent Option
- Distinct Visibility Enhancement: Special surface treatment may offer even clearer imaging, helping operators confirm catheter position swiftly.
- Reduced Residue Attachment: Potential for easier cleaning during dwell time or repositioning.
Flexible & Safe
- Ergonomic Pigtail Configuration: Minimizes risk of migration or patient discomfort, effectively anchoring the catheter in the renal pelvis or calyces.
- Secure Drainage: Preserves urinary outflow during ongoing treatment for renal tumors or inflammatory causes of obstruction, reducing back-pressure injury and pain.
Clinical Applications & Benefits
Upper Ureter & Renal Obstructions
- Gentle on Tissues: Flexible, smooth material reduces trauma during placement and long-term indwelling, enhancing patient comfort.
- Durable & Resistant: Maintains structural integrity under continuous drainage conditions.
Procedural Efficiency
- Secure, Kink-Resistant Drainage: Resilient design prevents catheter collapse in tortuous renal pathways or while navigating challenging anatomical angles.
- Robust Performance: Maintains uninterrupted flow, limiting the risk of catheter occlusion or displacement.
Reduced Patient Discomfort
- Marked with Radiopaque Bands: Ensures consistent fluoroscopic or ultrasound visibility for precise, real-time positioning.
- Graduated Depth Markings: Facilitates accurate placement in the renal collecting system, reducing repeated repositioning attempts.
Versatile Catheter Lengths
- Adaptable to Various Patient Profiles: Multiple pusher lengths accommodate deeper or more proximal access routes, supporting diverse procedural needs.
- Ease of Use: Simplifies advancement and stabilization in extended or anatomically complex drainage paths.
Especificaciones técnicas
Parameter | Especificación |
Material del catéter | Soft, biocompatible polyurethane |
Catheter Profile | 5F–7F (range may vary by model; consult labeling) |
Longitudes | Pusher rods from 40–100 cm; catheter lengths can vary (consult device label) |
Radiopacidad | High radiopacity for fluoroscopic guidance |
Depth Scale | Marked increments for accurate positioning |
Construction | Flexible pigtail tip to reduce displacement and vessel trauma |
Indicaciones | Upper ureteral & renal obstructions (tumors, inflammatory diseases) |
Optional Features | Radiopaque repellent coating, advanced trackability |
Productos relacionados
-
Catéteres guía AngioCATH
Leer másCatéteres guía de alto rendimiento con par óptimo respuesta y punta precisa formas para coronaria o periféricos intervenciones, garantizando la estabilidad del dispositivo y la claridad de las imágenes.
-
Extender Catéter con balón PTCA
Leer másA estándar alta presión balón coronario diseñado para predilatación de lesiones o independiente angioplastiaque ofrece perfiles de inflado precisos y perfiles de cruce reducidos.
-
Hero Mechanical Lead Removal System
Leer másA mecánico alternative for lead extraction, employing specialized locking stylets or sheaths to dislodge fibrotic attachments, ensuring steady traction for safe removal.
-
Atlas Sistema de stent coronario de acero inoxidable
Leer másA acero inoxidable oferta de stents coronarios robusto integridad estructural y fácil para intervenciones coronarias percutáneas (ICP) rutinarias, equilibrando la rentabilidad con un rendimiento fiable.