AnkaCATH Catéter de acceso distal neurovascular
A acceso distal catéter especializado para neurovascular intervenciones, ofreciendo mejorado capacidad de empuje, seguimiento y soporte estable de microcatéteres en vasos cerebrales profundos.
Navigate with Precision and Reach with Confidence Using the AnkaCATH
- AnkaCATH is designed for distal placement into the neurovasculature, providing intracranial support and a wide range of device compatibility.
Experience Superior Performance and Unmatched Access
- Exceptionally soft distal segment allows for excellent navigability and trackability into distal anatomy, enabling the AnkaCATH Catheter to provide support close to the treatment site.
Hybrid Design for Maximum Performance
- Hybrid Braid and Coil Design provides 1:1 push/pull control for enhanced trackability.
- Coil reinforcement provides lumen integrity, flexibility and excellent shape retention.
- Proximal variable pitch braid reinforcement provides support and torque control.

Torque Braid Overlay Provides Vital Torque Control
Sharpability
Stability
Coil
Diseño
Kink Resistance Inner Layer Braided
Navigate
- Material: Constructed with a durable, biocompatible Hybrid Braid and Coil Design for enhanced stability.
- Length: Extended sheath length to facilitate access to distal vascular territories.
- Flexibility: Engineered to provide optimal flexibility while maintaining structural integrity.
- Diameter Range: Available in various sizes to accommodate different procedural needs.
- Radiopacity: Enhanced radiopacity for improved visualization under imaging.
- Kink Resistance: Superior hybrid design offers excellent resistance to kinking and deformation.
- Hemostasis: Efficient hemostatic properties to minimize blood loss during procedures.
- Compatibility: Compatible with a wide range of interventional devices and guide wires.
- Length: Extended sheath length to facilitate access to distal vascular territories.
SUPERIOR
MICROCATHETER
PERFORMANCE
& RELIABLE DEVICE
DELIVERY
- High bending resistance with excellent torque control and optimum push through from proximal shaft to the distal end.
- Available in a variety of sizes, the AnkaCATH Catheter to diverse procedural requirements, ensuring a perfect fit for every patient.
- The enhanced radiopacity of the sheath allows for excellent visualization under imaging, aiding clinicians in precise navigation and placement.
- Unique hybrid braided design provides stability and support throughout the procedure, providing a sturdy yet flexible solution for expanded vascular access.
- This design contributes to the sheath’s exceptional bending resistance, maintaining integrity even in the most demanding situations.
- The rounded tip and flexible distal zone on the Distal Access Catheter are designed for confident advancement into fragile distal vessels.
- The design of Distal Access Catheter is designed for closer placement to the treatment site. Focus on the intervention, not access challenges.
Variable Stiffness & Braided Shaft
- PE/PEBAX Outer: Balances proximal rigidity for pushability with distal softness for atraumatic navigation in neurovasculature.
- Reinforced Design: A braided core ensures torsional stability, kink resistance, and secure device passage, even in sharply curved intracranial segments.
Non-Conical Large Lumen
- Generous Inner Diameter (0.071” – 0.075”): Accommodates multiple interventional devices or larger guidewires (up to 0.035”), reducing the need for multiple catheters.
- PTFE-Lined: Low-friction lumen supports smooth device transitions, crucial in time-sensitive stroke or aneurysm care.
Revestimiento hidrófilo distal
- Friction Reduction: The final centimeters of the distal segment are coated with a slippery surface, easing catheter advancement or repositioning through challenging anatomies.
- Vessel Protection: Minimizes endothelial trauma and reduces the risk of vasospasm or dissection during repeated manipulations.
Radiopaque Marker & Visibility
- 1 mm Marker at 2 mm from the Distal Tip: Distinct fluoroscopic marking for precise tip placement, vital in intracranial interventions.
- Radiopaque Distal Segment: Facilitates continuous imaging guidance under X-ray to confirm safe navigation and device deployment.
Multiple Sizes & Lengths
- Proximal Profiles (4F, 5F, 6F): Offer varied support levels, addressing a range of patient anatomies and procedure complexities.
- Usable Lengths (90 cm, 120 cm): Suitable for short or extended vascular paths, from moderate to more proximal femoral/radial entry routes.
Universal Hub Connection
- Luer-Lok Hub: Securely attaches accessories (e.g., hemostatic valve, flush lines), ensuring steady control of infusions or device insertions.
Especificaciones del producto
Especificación | Detalle / Valor |
Nombre del producto | AnkaCATH Catéter de acceso distal neurovascular |
Uso previsto | Facilitates distal access in neurovascular interventions (e.g., stroke thrombectomy, aneurysm coiling) |
Diseño del catéter | Braided or coiled shaft for torque and push, softer distal segment for atraumatic navigation |
Material | Pebax/Poliamida con refuerzo de acero inoxidable o nitinol |
Diámetro exterior (F) | ~3F–5F (depending on product code) |
Lumen interior | Compatible with microcatheters (0.016–0.027” ID), or direct device passage |
Longitud de trabajo | ~90–125 cm (varies by code) |
Configuración de la punta | Soft, radiopaque distal tip, potentially hydrophilic coating |
Marcadores radiopacos | 1–2 near distal zone for precise fluoroscopic tracking |
Sheath/Guide Compatibility | Typically 6F or 7F guide catheters for proximal support |
Esterilidad | Estéril, un solo uso |
Vida útil | ~2-3 años si se almacena a 15-25 °C en envase cerrado |
Indicaciones clínicas | Intracranial thrombectomy, aneurysm coiling, distal AVM catheterization |
Contraindicaciones | Extremely tortuous or stenotic intracranial vessels beyond feasible access, known device material allergy |
Matriz de pedidos y tamaños
Diámetro exterior (F) | Longitud de trabajo (cm) | Lumen ID (inch) | Código del producto | Notas |
3F | 90 | 0.016" | ANK-NV-3F-90-016 | Smaller OD for micro-aneurysm or distal stroke interventions |
3F | 105 | 0.016" | ANK-NV-3F-105-016 | Longer approach, same small lumen |
4F | 90 | 0.021" | ANK-NV-4F-90-021 | Common distal access for moderate neurovascular tasks |
4F | 105 | 0.021" | ANK-NV-4F-105-021 | Extended length for deeper intracranial navigation |
4F | 125 | 0.021" | ANK-NV-4F-125-021 | Max length for tall patients or complex anatomies |
5F | 105 | 0.027" | ANK-NV-5F-105-027 | Larger lumen for mechanical thrombectomy devices |
5F | 125 | 0.027" | ANK-NV-5F-125-027 | Maximum length plus wide ID for advanced neuro devices |
Productos relacionados
-
VascuVac Tecnologías de trombectomía de vacío asistida por Ai
Leer másUn sistema innovador que utiliza tecnología asistida por IA para una trombectomía de vacío eficaz, diseñado para eliminar rápidamente los trombos de los vasos sanguíneos, restablecer el flujo sanguíneo, y minimizar los riesgos del procedimiento en intervenciones vasculares.
-
Libro Agente de embolización no adhesivo: EVOH, DMSO y Tantalio
Leer másA no adhesivo sistema embólico líquido que combina EVOH, DMSO y tantalio para controlado desvascularización de MAV o tumor vasos de alimentación, lo que garantiza un despliegue preciso sin adherencia permanente a los vasos.
-
AspireJET Dispositivo de Aspiración Neurovascular
Leer másUn sistema avanzado diseñado para la eliminación precisa y eficaz de trombos y émbolos en procedimientos neurovasculares, garantizando el rápido restablecimiento del flujo sanguíneo al tiempo que se minimizan los riesgos del procedimiento.
-
KinG Dispositivo de revascularización intracraneal
Leer másA recuperador de stents o restauración de flujos dispositivo para agudos ictus isquémicocapturando y eliminando grandes coágulos de las arterias intracraneales, restableciendo rápidamente la perfusión.