Rapid and Reliable Embolization for Critical Moments
- The Filler Cyanoacrylate-Based Embolization Agent is distinguished by its rapid polymerization and targeted application, ensuring immediate and reliable vessel occlusion.
- Filler works by causing an inflammatory reaction over the endothelium of the target vein upon the injection of the polymer and simultaneous pressure application.
Secure Occlusion, Superior Outcomes
- Its high-viscosity formulation and compatibility with standard catheters enhance control during application, minimizing the risk of non-target embolization.
- Filler was developed for the treatment of peripheral and neurovascular, including arteriovenous malformations and hypervascular tumors by a simple polymerization method.
- Small amounts of polymer were delivered endovenous and pressure of up to 2-3 minutes to applied for total closure.

CAN BE
PERFORMED
SAFELY
Filler: Precision Embolization, Promising Results
Designed for biocompatibility, Filler minimizes inflammatory responses post-embolization, promoting patient safety and recovery. Choose Filler for a cutting-edge embolization solution that delivers superior outcomes and sets the standard in vascular care.
- Agent Type: Cyanoacrylate-based embolization agent.
- Composition: A high-viscosity liquid embolic agent, consisting of cyanoacrylate, designed for controlled and targeted embolization.
- Mechanism of Action: Rapid polymerization upon contact with ionic substances such as blood, leading to instant vessel occlusion.
- Indications: Suitable for arteriovenous malformations, gastrointestinal bleeding, and pre-surgical embolization.
- Application: Delivered through standard catheters, allowing for precise application and minimization of non-target embolization.
- Biocompatibility: Designed to be biocompatible and minimize inflammatory responses post-embolization.
- Composition: A high-viscosity liquid embolic agent, consisting of cyanoacrylate, designed for controlled and targeted embolization.
FAST
EFFECTIVE
& EASY
Filler Cyanoacrylate-Based Embolization Agent stands out as a cutting-edge solution for targeted and rapid vascular occlusion. Its high-viscosity liquid form, comprised of cyanoacrylate, is expertly designed to ensure controlled application and immediate results.
Upon contact with ionic substances such as blood, Filler rapidly polymerizes, leading to instant and durable vessel occlusion. This makes it an ideal choice for critical applications such as arteriovenous malformations, gastrointestinal bleeding, and pre-surgical embolization. Its delivery through standard catheters ensures precise application, reducing the risk of non-target embolization and enhancing procedural success.

- Neuro Aneurysms and AVMs
- Abdominal Aneurysms, Endoleaks
- Neurovascular & Peripheral Aneurysms and AVMs
- Short procedure procedure time.
- Mix with lipiodol for radiopacity
Filler is delivered through a microcatheter into the AVM under fluoroscopic control.
Filler immediately forms a skin as the polymeric embolus solidifies from the outside to the inside, while traveling more distally in the vessel.
Type 2 endoleak from lumbar arteries. (A) Computed tomography (CT) scan in the procubitus position shows posterior opacification of the periprosthetic aneurysmal sac (nidus). (B) Embolization of the endoleak center with a microcatheter under CT guidance until nidus opacification is complete.
產品規格
規格 | 細節 / 價值 |
產品名稱 | Filler Cyanoacrylate Embolization Agent |
預期用途 | Embolization of AVMs, fistulas, varices, or other lesions requiring permanent vascular occlusion |
Composition | n-Butyl or n-Hexyl cyanoacrylate formulation, polymerizes rapidly upon contact with blood/tissue |
Polymerization Mechanism | Instant polymerization triggered by ionic/aqueous environment |
Delivery Method | Via microcatheter (coaxial with DMSO or compatible flushing agent, if needed) |
放射能力 | May require added radiopaque contrast (e.g., Lipiodol) for fluoroscopic visibility |
Viscosity | Low to medium (check final specs), allowing controlled injection time |
無菌 | 無菌,單次使用 |
保質期 | 在 15-25 °C 密封包裝下 ~2-3 年 |
臨床適應症 | Neurovascular or peripheral AVM occlusion, gastrointestinal bleeders, variceal management, certain tumor devascularizations |
禁忌症 | Vessel lumens too small for catheter access, potential risk if accidental nontarget injection, known allergy to cyanoacrylates |
訂購與尺寸表
Cyanoacrylate Concentration (%) | Vial Volume (mL) | Recommended Mixing Ratio | 產品編號 | 注意事項 |
33 | 1.0 | 1:1 with radiopaque agent | FIL-33-1.0-1:1 | Lower concentration, slower polymerization, suitable for distal lesions |
33 | 2.0 | 1:1 | FIL-33-2.0-1:1 | Larger vial, same concentration |
50 | 1.0 | 1:0.5 | FIL-50-1.0-1:0.5 | Faster set time, moderate volume |
50 | 2.0 | 1:0.5 | FIL-50-2.0-1:0.5 | Larger volume for multiple feeders |
67 | 1.0 | 1:0.25 | FIL-67-1.0-1:0.25 | High concentration, rapid polymerization for high-flow lesions |
67 | 2.0 | 1:0.25 | FIL-67-2.0-1:0.25 | Maximum control in large or complex AVMs |
相關商品
-
Atlas 主動脈鈦合金支架
查看內容A 自我膨脹 設計用於 大動脈 病變覆蓋,維持 靈活 徑向力以穩定錨定在 胸腔 或 腹部 主動脈解剖。
-
Texten: Advanced Cyanoacrylate Tissue Adhesive
查看內容A fast-acting, biocompatible adhesive designed for wound closure and surgical applications, providing strong tissue bonding, reduced scarring, and an effective alternative to sutures and staples.
-
Keeper 血管內卡環
查看內容A 多回路 捕捉器 異物 或 栓塞 捕捉,確保 (经过努力)获得 參與和 退出 來自血管腔。
-
SteerCATH 可調式導管