AngioTEN Closure Device by INVAMED is a cyanoacrylate-based closure system designed to seal and stabilize the access site after angiographic procedures. Equipped with a specialized applicator, it ensures precise and user-friendly application of the adhesive over vascular puncture sites, reducing bleeding complications and enhancing patient recovery. By combining rapid polymerization with a biocompatible formula, AngioTEN helps minimize pseudoaneurysm formation and shortens manual compression time—optimizing clinical workflow in catheterization labs.
Cyanoacrylate Adhesive Technology
Employs a fast-curing medical-grade cyanoacrylate that bonds rapidly to tissue edges, helping create a secure and durable seal at the arterial or venous puncture site.
Ergonomic Applicator
Features a slim, intuitive applicator that allows precise dropwise or thin-stripe application, ensuring minimal adhesive wastage and targeted closure even in narrow access points.
Rapid Hemostasis
By instantly sealing the puncture track, AngioTEN reduces the need for prolonged manual compression or adjunct compression devices, potentially improving patient comfort and catheter lab throughput.
Biocompatible & Safe
Formulated to minimize tissue irritation and promote natural healing processes. Ideal for radial or femoral access closure after diagnostic angiography or interventional procedures.
Reduced Risk of Complications
Stabilizing the access site lowers the incidence of hematoma, pseudoaneurysm, or AV fistula formation, supporting safer vascular interventions and quicker discharge protocols.
禁忌症
- Heavy calcification, severely diseased artery walls
- Uncontrolled bleeding or coagulopathy beyond standard care measures
- Infection at the puncture site
產品規格
規格 | 細節 / 價值 |
產品名稱 | AngioTEN 閉合裝置 |
預期用途 | Percutaneous vascular closure post-catheterization |
Closure Mechanism | Suture-mediated or collagen plug |
Applicable Access Sites | Femoral artery/vein up to 8F–10F introducer sizes |
Deployment Method | Single-step device insertion and anchor release |
Hemostasis Time | Typically < 1 minute post-deployment |
無菌 | 無菌,單次使用 |
保質期 | ~2–3 years at 15–25 °C |
訂購與尺寸表
Access Size (F) | Closure Method | Deployment Steps | 產品編號 |
5–8 | Collagen Plug | Single | ATN-CP-5-8-S |
5–8 | Suture-Mediated | Single | ATN-SM-5-8-S |
8–10 | Collagen Plug | Single | ATN-CP-8-10-S |
8–10 | Suture-Mediated | Single | ATN-SM-8-10-S |
相關商品
-
Extender 紫杉醇藥物洗淨 PTCA 球囊導管
查看內容A 紫杉醇塗層 冠狀動脈球囊導管,旨在 減少再狭窄 在經皮冠狀血管成形術 (PTCA) 期間,可確保有效地將藥物輸送到血管壁。
-
Atlas 冠狀動脈支架移植系統
查看內容A 有蓋冠狀動脈支架 系統提供 腔外 密封 穿孔 或 假性動脈瘤以維持冠狀動脈的通暢,同時防止血液外流。
-
Lotus Single Lumen & Double Lumen (RX) PTCA Microcatheter
查看內容Microcatheters 專為 冠脉 or peripheral lesion crossing, offering single- or double-lumen configurations for guidewire exchange, contrast injection, or subselective lesion access.
-
Hero 機械式除鉛系統
查看內容A 機械 的替代方案 鉛提取使用專門的鎖定插銷或鞘,以 去除 纖維化附著物,確保 沉穩 可安全移除的牽引力。