"(《世界人权宣言》) PetaⓇ Sternum Closure Plate addresses the challenges associated with fixating a 90-degree sternal incision or rib osteotomy through an anatomically contoured, low-profile design. Constructed from a highly biocompatible Ti-6Al-4V-ELI alloy and featuring a user-friendly locking block, PetaⓇ provides secure and re-tensionable closure, ensuring optimal stability and patient comfort.
Low-Profile Design
- Minimally Invasive Access: The plate’s thin profile accommodates incisions in tight anatomical spaces, lessening postoperative discomfort and risk of soft tissue irritation.
- Anatomical Contouring: Engineered to conform seamlessly to the curvature of the sternum or rib, enhancing implant stability while preserving natural bone alignment.
Locking Block with Ti-6Al-4V-ELI Alloy
- Highly Biocompatible: The titanium alloy demonstrates excellent osseointegration and minimal inflammatory response, making it suitable for long-term surgical implants.
- Secure Lock Mechanism: Once fixed by the locking-block screw, there is no risk of self-loosening or accidental opening—critical for maintaining consistent compression across the osteotomy site.
- Re-Tension Capability: The locking block screw can be loosened intraoperatively to re-tension the plate, streamlining adjustments and shortening operating room time.
- Secure Lock Mechanism: Once fixed by the locking-block screw, there is no risk of self-loosening or accidental opening—critical for maintaining consistent compression across the osteotomy site.
Magnetic Resonance (MR) Compatibility
- Advanced Imaging Safety: MR compatibility ensures that patients requiring postoperative MRI can undergo imaging with minimal artifact and without necessitating plate removal.
- Clinically Versatile: This feature is especially valuable for complex cases that demand ongoing multimodal imaging for diagnosis or follow-up.
Technical Advantages
Enhanced Stability
The rigid fixation achieved through titanium alloy construction and a low-profile locking system improves bone healing and reduces micromotion, crucial factors in preventing non-union or delayed union.
Reduced Postoperative Pain
An anatomically contoured plate can decrease soft tissue irritation, potentially lowering patient discomfort and accelerating recovery timelines.
Surgeon-Controlled Tensioning
The ability to modify or re-tension the locking block screw intraoperatively offers precise control over compression, alignment, and overall surgical outcome.
Versatility in Plate Placement
Multiple plate lengths and shapes (depending on the system’s available catalog) enable surgeons to tailor the fixation construct to specific patient anatomies and surgical approaches.
一般产品规格
规格 | 细节/价值 |
产品名称 | Peta 胸骨闭合板 |
预期用途 | Rigid fixation of the sternum post sternotomy (open-heart surgery, thoracic intervention) |
Plate Material | Titanium alloy (e.g., Ti-6Al-4V ELI) or Stainless Steel (316L), depending on product line |
Plate Thickness | ~1.0–1.5 mm (typical range; verify your actual specs) |
Plate Width | ~10–15 mm (to provide adequate coverage over sternal edges) |
Hole Configuration | Round or oval holes for bone screws, spaced at intervals for adjustable fixation |
Screw Compatibility | Typically 2.4 mm or 2.7 mm diameter cortical bone screws (confirm actual) |
Anatomical Shape | May include slightly contoured or “anatomical” plates for better sternal conformance |
MR 兼容性 | MR Conditional or Safe, depending on final metal composition |
无菌 | Sterile (Gamma or EO) |
一次性使用 | 是 |
保质期 | ~5 years if packaging remains sealed |
临床适应症 | Midline sternotomy closure, sternal stability improvement, prevention of dehiscence or infection |
禁忌症 | Grossly insufficient bone stock, active sternal infection (needing further debridement first), etc. |
Peta Sternal Plates
Plate Length (mm) | Hole Count | Thickness (mm) | Plate Shape | 产品代码 | 说明 |
40 | 4 | 1.0 | Straight | PETA-40-4-1.0-S | Short plate for partial sternal closure segments |
40 | 4 | 1.2 | Curved | PETA-40-4-1.2-CV | Slight curvature to match upper manubrium |
50 | 5 | 1.0 | Straight | PETA-50-5-1.0-S | Medium length, minimal thickness |
50 | 5 | 1.2 | Slightly contoured | PETA-50-5-1.2-SC | Subtle sternal conformance |
60 | 6 | 1.0 | Straight | PETA-60-6-1.0-S | Extended length for broader sternums |
60 | 6 | 1.2 | Curved | PETA-60-6-1.2-CV | Curved design for mid-lower sternum |
60 | 8 | 1.5 | Straight | PETA-60-8-1.5-S | Additional hole count for robust fixation, thicker plate version |
70 | 6 | 1.0 | Slightly contoured | PETA-70-6-1.0-SC | Longer coverage, minimal thickness |
70 | 8 | 1.2 | Curved | PETA-70-8-1.2-CV | More hole options for multi-screw stability, moderate thickness |
80 | 8 | 1.2 | Straight | PETA-80-8-1.2-S | Extended length for full sternum coverage |
80 | 10 | 1.5 | Slightly contoured | PETA-80-10-1.5-SC | Thicker plate, extended length, multiple hole fixations |
90 | 10 | 1.2 | Curved | PETA-90-10-1.2-CV | Very long plate for entire sternotomy line in certain surgeries |
90 | 12 | 1.5 | Straight | PETA-90-12-1.5-S | Maximum hole count for comprehensive fixation, thicker plate |
相关产品
-
Hero 激光除铅系统
阅读更多A 激光 提取装置 严丝合缝 和 安全的 清除 心导联 (起搏器或 ICD)感染、导线故障或升级的情况。
-
AngioCATH 导引导管
阅读更多具有以下功能的高性能导引导管 最佳扭矩 反应和 精确提示 形状为 冠脉 或 外围 干预,确保稳定的设备输送和成像清晰度。
-
Extender PTCA 球囊导管
阅读更多A 标准 高压 冠脉球囊 专为 病变预处理 或独立 血管成形术可提供精确的充气曲线和较小的交叉曲线。
-
Lotus 单腔和双腔(RX)PTCA 微导管
阅读更多微导管 专为 冠脉 或外围病变穿越,提供单腔或双腔配置,用于 导丝交换, 造影剂注射或次选择性病变通路。