Ống thông hỗ trợ chéo thấp Dolphin PRO
MỘT thấp thấp ống thông qua với tăng cường khả năng đẩy Và khả năng theo dõi, được thiết kế cho chặt hoặc nặng nề vôi hóa tổn thương ở động mạch vành hoặc động mạch ngoại biên.
The Dolphin® Pro Low Profile Crossing Support Catheter developed by Invamed, a global medical device manufacturer—is designed for precise and efficient guidewire support in complex vascular interventions. Built to navigate tight or tortuous anatomies, this low-profile catheter integrates three radiopaque markers along the distal shaft, enabling improved positional awareness and accurate lesion crossing in both peripheral arteries.
Triple Marker System
- Three strategically placed markers along the distal segment enhance fluoroscopic visibility, facilitating precise depth and orientation checks when crossing tough occlusions.
Low-Profile Construction
- Optimized for smaller vessel diameters or micro-channel crossing, reducing friction and minimizing vessel trauma.
High Pushability & Torque
- Braided or coiled shaft provides robust support while retaining flexibility, ensuring stable guidewire manipulation through heavily calcified or occluded segments.
Multi-Use Applications
- Ideal for peripheral artery disease (PAD) or complex coronary lesion crossing, offering consistent performance in subintimal or luminal track approaches.
Thông số kỹ thuật chung của sản phẩm
Đặc điểm kỹ thuật | Chi tiết / Giá trị |
Tên sản phẩm | Ống thông hỗ trợ chéo thấp Dolphin PRO |
Mục đích sử dụng | Facilitates wire crossing in complex or chronic total occlusion (CTO) lesions, primarily in smaller or distal vessels |
Thiết kế ống thông | Ultra-low profile shaft, possible braided or coiled backbone for torque and push, hydrophilic coating (if applicable) |
Vật liệu | Pebax/Polyamide với thép không gỉ hoặc gia cố nitinol |
Phạm vi đường kính ngoài | ~1.8–2.3 Fr (depending on model) |
Lumen bên trong | Typically 0.014” wire compatibility |
Chiều dài làm việc | ~80–150 cm, depending on specific code |
Cấu hình đầu tip | Tapered or angled tip, radiopaque distal marker |
Marker Bands | 1–2 marker bands near the distal end for precise fluoroscopic visualization |
Sheath Compatibility | Typically 4F or smaller introducer (due to low-profile design) |
Vô sinh | Vô trùng (Ethylene Oxide) |
Sử dụng một lần | Đúng |
Hạn sử dụng | ~2–3 years if stored in sealed packaging at 15–25 °C |
Chỉ định lâm sàng | Complex lesion crossing in smaller or distal vessels (BTK arteries, small coronaries, etc.), fine device support |
Chống chỉ định | Extremely calcified or tortuous anatomies beyond safe manipulation, known device material allergies |
Dolphin PRO Low Profile
Fr Size | Chiều dài làm việc (cm) | Tip Style | Mã sản phẩm | Ghi chú |
1.8 Fr | 80 | Straight | DLP-1.8-80-ST | Ultra-low OD for very small vessels or subintimal approaches |
1.8 Fr | 80 | Tapered | DLP-1.8-80-TP | Tapered tip for crossing tight CTO caps |
1.8 Fr | 100 | Straight | DLP-1.8-100-ST | Longer length for distal BTK or small coronary tracks |
2.0 Fr | 80 | Angled | DLP-2.0-80-AN | Slightly bigger OD, angled tip for branch approach |
2.0 Fr | 100 | Straight | DLP-2.0-100-ST | Balanced push + track in small peripheral arteries |
2.0 Fr | 135 | Tapered | DLP-2.0-135-TP | Extended length for multi-segment crossing |
2.2 Fr | 80 | Straight | DLP-2.2-80-ST | Enhanced lumen for 0.014” wire plus small device passage |
2.2 Fr | 100 | Angled | DLP-2.2-100-AN | Angled tip for difficult side branches |
2.2 Fr | 135 | Tapered | DLP-2.2-135-TP | Tapered distal tip + long working length |
2.3 Fr | 135 | Straight | DLP-2.3-135-ST | Largest OD in the low-profile series, for moderate vessel size |
2.3 Fr | 150 | Tapered | DLP-2.3-150-TP | Maximum length in low-profile design |
Sản phẩm tương tự
-
Ống thông hỗ trợ chéo Dolphin ZEBRA
Đọc tiếpMột chuyên ngành Mẫu ZEBRA ống thông hỗ trợ tráng phủ tối ưu hóa khả năng hiển thị dưới màn huỳnh quang, cho phép tổn thương giao nhau một cách nhất quán trong tổ hợp sự tắc nghẽn.
-
Hệ thống stent mạch vành giải phóng thuốc ATLAS Cobalt Crom
Đọc tiếpMỘT coban-crom stent động mạch vành sức mạnh xuyên tâm bền bỉ Và khả năng theo dõi tuyệt vời, phù hợp cho tổ hợp hoặc vôi hóa tổn thương động mạch vành trong khi vẫn đảm bảo độ giật tối thiểu.
-
Dây dẫn CTO InWIRE 0,014” & 0,018”
Đọc tiếpMột loạt các hiệu suất cao cung cấp dây dẫn bền bỉ nitinol hoặc không gỉ lõi, lớp phủ ưa nước và nhiều hình dạng đầu để vượt qua vôi hóa hoặc tổ hợp tổn thương động mạch vành và ngoại biên.
-
Stent ghép ngoại biên nội mạch Atlas
Đọc tiếpMỘT stent ngoại biên được che phủ cung cấp ghép chắc chắn tắc nghẽn phình động mạch hoặc tổn thương tắc nghẽn trong chậu hoặc xương đùi các đoạn, giảm nguy cơ vỡ hoặc tắc nghẽn trở lại.