Hệ thống stent mạch vành giải phóng thuốc ATLAS Cobalt Crom
MỘT coban-crom stent động mạch vành sức mạnh xuyên tâm bền bỉ Và khả năng theo dõi tuyệt vời, phù hợp cho tổ hợp hoặc vôi hóa tổn thương động mạch vành trong khi vẫn đảm bảo độ giật tối thiểu.
Các ATLAS Drug Eluting Coronary Stent System is a next-generation cobalt-chromium (CoCr) stent platform coated with a sirolimus formulation (1 µg/mm²) designed to reduce restenosis in patients with coronary artery disease. By combining advanced laser-cutting technology and a clinically proven antiproliferative drug, the ATLAS system delivers durable vessel patency and a high safety profile in both de novo lesions and in-stent restenosis scenarios.
Cobalt-Chromium Alloy (L605) Construction
- Ensures exceptional strength-to-thickness ratio, enabling thinner struts without compromising radial force.
- Exhibits excellent corrosion resistance and biocompatibility for a stable healing environment.
Laser-Cut Stent Design
- Precision machining yields consistent strut geometry, promoting uniform drug distribution and an even healing surface along the vessel wall.
- Enhances stent deliverability, allowing smooth passage through calcified or tortuous coronary segments.
Sirolimus Elution Profile
- 1 µg/mm² of sirolimus is coated onto the stent’s surface, ensuring a sustained, controlled release that minimizes in-stent neointimal growth.
- Controlled drug release aids in rapid endothelialization, lowering the risk of late stent thrombosis.
Radiopaque Pt-Ir Markers
- Platinum-iridium markers at stent edges enable precise visibility under fluoroscopy.
- Facilitates accurate positioning during percutaneous coronary intervention (PCI) procedures.
High-Pressure Capability
interventional cardiologists flexibility to optimize stent expansion based on lesion complexity.
Đặc điểm kỹ thuật | Chi tiết / Giá trị |
Tên sản phẩm | Atlas Coronary Stent (Cobalt Chromium) |
Stent Type | Balloon-Expandable Coronary Stent |
Vật liệu | Cobalt-Chromium Alloy |
Strut Thickness | ~80 µm (typical) |
Thiết kế | Open-cell or hybrid-cell architecture (depending on exact model) |
Nominal Pressure (NP) | 9–10 atm |
Rated Burst Pressure (RBP) | ~14–16 atm |
Stent Delivery System | Rapid-Exchange (RX) or Over-the-Wire (OTW), typically 140 cm shaft length |
Khả năng tương thích của Guidewire | 0.014” |
Stent Surface | Bare-metal or optional drug-eluting polymer (if applicable) |
Chỉ định | Coronary artery lesion scaffolding, single or multivessel disease, potential usage in small/medium/large vessels |
Chống chỉ định | Lesions unsuited for balloon-expandable stent therapy (e.g., severely calcified, left main trunk, etc.), or as per physician discretion |
Vô sinh | Vô trùng (Ethylene Oxide) |
Sử dụng một lần | Đúng |
Hạn sử dụng | 2–3 years (depending on final packaging and polymer, if any) |
Nhiệt độ hoạt động | Recommended 15–25 °C for storage |
Đặt hàng theo kích thước chi tiết & Mã sản phẩm
Stent Diameter (mm) | Stent Length (mm) | Nominal Pressure (atm) | RBP (atm) | Mã sản phẩm |
2.00 | 8 | 9 | 14 | ATLS-CC-2.00x08 |
2.00 | 12 | 9 | 14 | ATLS-CC-2.00x12 |
2.00 | 15 | 9 | 14 | ATLS-CC-2.00x15 |
2.00 | 18 | 10 | 16 | ATLS-CC-2.00x18 |
2.00 | 24 | 10 | 16 | ATLS-CC-2.00x24 |
2.00 | 28 | 10 | 16 | ATLS-CC-2.00x28 |
2.00 | 32 | 10 | 16 | ATLS-CC-2.00x32 |
2.00 | 38 | 10 | 16 | ATLS-CC-2.00x38 |
2.25 | 8 | 9 | 14 | ATLS-CC-2.25x08 |
2.25 | 12 | 9 | 14 | ATLS-CC-2.25x12 |
2.25 | 15 | 9 | 14 | ATLS-CC-2.25x15 |
2.25 | 18 | 10 | 16 | ATLS-CC-2.25x18 |
2.25 | 24 | 10 | 16 | ATLS-CC-2.25x24 |
2.25 | 28 | 10 | 16 | ATLS-CC-2.25x28 |
2.25 | 32 | 10 | 16 | ATLS-CC-2.25x32 |
2.25 | 38 | 10 | 16 | ATLS-CC-2.25x38 |
2.50 | 8 | 9 | 14 | ATLS-CC-2.50x08 |
2.50 | 12 | 9 | 14 | ATLS-CC-2.50x12 |
2.50 | 15 | 9 | 14 | ATLS-CC-2.50x15 |
2.50 | 18 | 10 | 16 | ATLS-CC-2.50x18 |
2.50 | 24 | 10 | 16 | ATLS-CC-2.50x24 |
2.50 | 28 | 10 | 16 | ATLS-CC-2.50x28 |
2.50 | 32 | 10 | 16 | ATLS-CC-2.50x32 |
2.50 | 38 | 10 | 16 | ATLS-CC-2.50x38 |
2.75 | 8 | 9 | 14 | ATLS-CC-2.75x08 |
2.75 | 12 | 9 | 14 | ATLS-CC-2.75x12 |
2.75 | 15 | 9 | 14 | ATLS-CC-2.75x15 |
2.75 | 18 | 10 | 16 | ATLS-CC-2.75x18 |
2.75 | 24 | 10 | 16 | ATLS-CC-2.75x24 |
2.75 | 28 | 10 | 16 | ATLS-CC-2.75x28 |
2.75 | 32 | 10 | 16 | ATLS-CC-2.75x32 |
2.75 | 38 | 10 | 16 | ATLS-CC-2.75x38 |
3.00 | 8 | 9 | 14 | ATLS-CC-3.00x08 |
3.00 | 12 | 9 | 14 | ATLS-CC-3.00x12 |
3.00 | 15 | 9 | 14 | ATLS-CC-3.00x15 |
3.00 | 18 | 10 | 16 | ATLS-CC-3.00x18 |
3.00 | 24 | 10 | 16 | ATLS-CC-3.00x24 |
3.00 | 28 | 10 | 16 | ATLS-CC-3.00x28 |
3.00 | 32 | 10 | 16 | ATLS-CC-3.00x32 |
3.00 | 38 | 10 | 16 | ATLS-CC-3.00x38 |
3.25 | 12 | 9 | 14 | ATLS-CC-3.25x12 |
3.25 | 15 | 9 | 14 | ATLS-CC-3.25x15 |
3.25 | 18 | 10 | 16 | ATLS-CC-3.25x18 |
3.25 | 24 | 10 | 16 | ATLS-CC-3.25x24 |
3.25 | 28 | 10 | 16 | ATLS-CC-3.25x28 |
3.25 | 32 | 10 | 16 | ATLS-CC-3.25x32 |
3.25 | 38 | 10 | 16 | ATLS-CC-3.25x38 |
3.50 | 8 | 9 | 14 | ATLS-CC-3.50x08 |
3.50 | 12 | 9 | 14 | ATLS-CC-3.50x12 |
3.50 | 15 | 9 | 14 | ATLS-CC-3.50x15 |
3.50 | 18 | 10 | 16 | ATLS-CC-3.50x18 |
3.50 | 24 | 10 | 16 | ATLS-CC-3.50x24 |
3.50 | 28 | 10 | 16 | ATLS-CC-3.50x28 |
3.50 | 32 | 10 | 16 | ATLS-CC-3.50x32 |
3.50 | 38 | 10 | 16 | ATLS-CC-3.50x38 |
4.00 | 8 | 9 | 14 | ATLS-CC-4.00x08 |
4.00 | 12 | 9 | 14 | ATLS-CC-4.00x12 |
4.00 | 15 | 9 | 14 | ATLS-CC-4.00x15 |
4.00 | 18 | 10 | 16 | ATLS-CC-4.00x18 |
4.00 | 24 | 10 | 16 | ATLS-CC-4.00x24 |
4.00 | 28 | 10 | 16 | ATLS-CC-4.00x28 |
4.00 | 32 | 10 | 16 | ATLS-CC-4.00x32 |
4.00 | 38 | 10 | 16 | ATLS-CC-4.00x38 |
Sản phẩm tương tự
-
Hệ thống Stent ngoại vi Atlas
Đọc tiếpMột sự mạnh mẽ stent ngoại vi nền tảng được thiết kế cho xương đùi, chậu, hoặc khoeo chân tổn thương, đảm bảo đủ hỗ trợ xuyên tâm và thấp tỷ lệ tái hẹp trong can thiệp PAD.
-
Hệ thống ghép stent động mạch vành Atlas
Đọc tiếpMỘT stent vành được che phủ hệ thống cung cấp ngoài lòng niêm phong trong lỗ thủng hoặc giả phình động mạch, duy trì sự thông suốt của động mạch vành trong khi ngăn ngừa thoát mạch.
-
Bộ điều chế lưu lượng đa lớp Stena cho thiết bị ngoại vi
Đọc tiếpChuyển hướng dòng chảy stent cho ngoại vi động mạch, phân phối lại tầng chảy ra khỏi các đoạn mạch bị bệnh, hỗ trợ bảo tồn phình động mạch hoặc nhánh bên.
-
Ống thông bóng PTCA Extender
Đọc tiếpMỘT tiêu chuẩn áp suất cao bóng bay động mạch vành được thiết kế cho sự giãn nở tổn thương hoặc độc lập nong mạch vành, cung cấp thông số lạm phát chính xác và giảm thiểu các thông số giao cắt.