ATLAS preparati koronar stent tizimi kobalt xrom
A kobalt-xrom koronar stent qo'yish bardoshli radial quvvat va ajoyib kuzatuv qobiliyati, uchun mos keladi murakkab yoki kalsifikatsiyalangan minimal orqaga qaytishni ta'minlagan holda koronar lezyonlar.
The ATLAS Drug Eluting Coronary Stent System is a next-generation cobalt-chromium (CoCr) stent platform coated with a sirolimus formulation (1 µg/mm²) designed to reduce restenosis in patients with coronary artery disease. By combining advanced laser-cutting technology and a clinically proven antiproliferative drug, the ATLAS system delivers durable vessel patency and a high safety profile in both de novo lesions and in-stent restenosis scenarios.
Cobalt-Chromium Alloy (L605) Construction
- Ensures exceptional strength-to-thickness ratio, enabling thinner struts without compromising radial force.
- Exhibits excellent corrosion resistance and biocompatibility for a stable healing environment.
Laser-Cut Stent Design
- Precision machining yields consistent strut geometry, promoting uniform drug distribution and an even healing surface along the vessel wall.
- Enhances stent deliverability, allowing smooth passage through calcified or tortuous coronary segments.
Sirolimus Elution Profile
- 1 µg/mm² of sirolimus is coated onto the stent’s surface, ensuring a sustained, controlled release that minimizes in-stent neointimal growth.
- Controlled drug release aids in rapid endothelialization, lowering the risk of late stent thrombosis.
Radiopaque Pt-Ir Markers
- Platinum-iridium markers at stent edges enable precise visibility under fluoroscopy.
- Facilitates accurate positioning during percutaneous coronary intervention (PCI) procedures.
High-Pressure Capability
interventional cardiologists flexibility to optimize stent expansion based on lesion complexity.
| Spetsifikatsiya | Tafsilot / qiymat |
| Mahsulot nomi | Atlas Coronary Stent (Cobalt Chromium) |
| Stent Type | Balloon-Expandable Coronary Stent |
| Material | Cobalt-Chromium Alloy |
| Strut Thickness | ~80 µm (typical) |
| Dizayn | Open-cell or hybrid-cell architecture (depending on exact model) |
| Nominal Pressure (NP) | 9–10 atm |
| Rated Burst Pressure (RBP) | ~14–16 atm |
| Stent Delivery System | Rapid-Exchange (RX) or Over-the-Wire (OTW), typically 140 cm shaft length |
| Guidewire muvofiqligi | 0.014” |
| Stent Surface | Bare-metal or optional drug-eluting polymer (if applicable) |
| Ko'rsatkichlar | Coronary artery lesion scaffolding, single or multivessel disease, potential usage in small/medium/large vessels |
| Qo'llash mumkin bo'lmagan holatlar | Lesions unsuited for balloon-expandable stent therapy (e.g., severely calcified, left main trunk, etc.), or as per physician discretion |
| Sterillik | Steril (etilen oksidi) |
| Bir martalik foydalanish | Ha |
| Yaroqlilik muddati | 2–3 years (depending on final packaging and polymer, if any) |
| Ishlash harorati | Recommended 15–25 °C for storage |
Batafsil o'lchamga asoslangan buyurtma va mahsulot kodlari
| Stent Diameter (mm) | Stent Length (mm) | Nominal Pressure (atm) | RBP (atm) | Mahsulot kodi |
| 2.00 | 8 | 9 | 14 | ATLS-CC-2.00x08 |
| 2.00 | 12 | 9 | 14 | ATLS-CC-2.00x12 |
| 2.00 | 15 | 9 | 14 | ATLS-CC-2.00x15 |
| 2.00 | 18 | 10 | 16 | ATLS-CC-2.00x18 |
| 2.00 | 24 | 10 | 16 | ATLS-CC-2.00x24 |
| 2.00 | 28 | 10 | 16 | ATLS-CC-2.00x28 |
| 2.00 | 32 | 10 | 16 | ATLS-CC-2.00x32 |
| 2.00 | 38 | 10 | 16 | ATLS-CC-2.00x38 |
| 2.25 | 8 | 9 | 14 | ATLS-CC-2.25x08 |
| 2.25 | 12 | 9 | 14 | ATLS-CC-2.25x12 |
| 2.25 | 15 | 9 | 14 | ATLS-CC-2.25x15 |
| 2.25 | 18 | 10 | 16 | ATLS-CC-2.25x18 |
| 2.25 | 24 | 10 | 16 | ATLS-CC-2.25x24 |
| 2.25 | 28 | 10 | 16 | ATLS-CC-2.25x28 |
| 2.25 | 32 | 10 | 16 | ATLS-CC-2.25x32 |
| 2.25 | 38 | 10 | 16 | ATLS-CC-2.25x38 |
| 2.50 | 8 | 9 | 14 | ATLS-CC-2.50x08 |
| 2.50 | 12 | 9 | 14 | ATLS-CC-2.50x12 |
| 2.50 | 15 | 9 | 14 | ATLS-CC-2.50x15 |
| 2.50 | 18 | 10 | 16 | ATLS-CC-2.50x18 |
| 2.50 | 24 | 10 | 16 | ATLS-CC-2.50x24 |
| 2.50 | 28 | 10 | 16 | ATLS-CC-2.50x28 |
| 2.50 | 32 | 10 | 16 | ATLS-CC-2.50x32 |
| 2.50 | 38 | 10 | 16 | ATLS-CC-2.50x38 |
| 2.75 | 8 | 9 | 14 | ATLS-CC-2.75x08 |
| 2.75 | 12 | 9 | 14 | ATLS-CC-2.75x12 |
| 2.75 | 15 | 9 | 14 | ATLS-CC-2.75x15 |
| 2.75 | 18 | 10 | 16 | ATLS-CC-2.75x18 |
| 2.75 | 24 | 10 | 16 | ATLS-CC-2.75x24 |
| 2.75 | 28 | 10 | 16 | ATLS-CC-2.75x28 |
| 2.75 | 32 | 10 | 16 | ATLS-CC-2.75x32 |
| 2.75 | 38 | 10 | 16 | ATLS-CC-2.75x38 |
| 3.00 | 8 | 9 | 14 | ATLS-CC-3.00x08 |
| 3.00 | 12 | 9 | 14 | ATLS-CC-3.00x12 |
| 3.00 | 15 | 9 | 14 | ATLS-CC-3.00x15 |
| 3.00 | 18 | 10 | 16 | ATLS-CC-3.00x18 |
| 3.00 | 24 | 10 | 16 | ATLS-CC-3.00x24 |
| 3.00 | 28 | 10 | 16 | ATLS-CC-3.00x28 |
| 3.00 | 32 | 10 | 16 | ATLS-CC-3.00x32 |
| 3.00 | 38 | 10 | 16 | ATLS-CC-3.00x38 |
| 3.25 | 12 | 9 | 14 | ATLS-CC-3.25x12 |
| 3.25 | 15 | 9 | 14 | ATLS-CC-3.25x15 |
| 3.25 | 18 | 10 | 16 | ATLS-CC-3.25x18 |
| 3.25 | 24 | 10 | 16 | ATLS-CC-3.25x24 |
| 3.25 | 28 | 10 | 16 | ATLS-CC-3.25x28 |
| 3.25 | 32 | 10 | 16 | ATLS-CC-3.25x32 |
| 3.25 | 38 | 10 | 16 | ATLS-CC-3.25x38 |
| 3.50 | 8 | 9 | 14 | ATLS-CC-3.50x08 |
| 3.50 | 12 | 9 | 14 | ATLS-CC-3.50x12 |
| 3.50 | 15 | 9 | 14 | ATLS-CC-3.50x15 |
| 3.50 | 18 | 10 | 16 | ATLS-CC-3.50x18 |
| 3.50 | 24 | 10 | 16 | ATLS-CC-3.50x24 |
| 3.50 | 28 | 10 | 16 | ATLS-CC-3.50x28 |
| 3.50 | 32 | 10 | 16 | ATLS-CC-3.50x32 |
| 3.50 | 38 | 10 | 16 | ATLS-CC-3.50x38 |
| 4.00 | 8 | 9 | 14 | ATLS-CC-4.00x08 |
| 4.00 | 12 | 9 | 14 | ATLS-CC-4.00x12 |
| 4.00 | 15 | 9 | 14 | ATLS-CC-4.00x15 |
| 4.00 | 18 | 10 | 16 | ATLS-CC-4.00x18 |
| 4.00 | 24 | 10 | 16 | ATLS-CC-4.00x24 |
| 4.00 | 28 | 10 | 16 | ATLS-CC-4.00x28 |
| 4.00 | 32 | 10 | 16 | ATLS-CC-4.00x32 |
| 4.00 | 38 | 10 | 16 | ATLS-CC-4.00x38 |
O' turdagi mahsulotlar
-

TemREN Rotablator
BatafsilA aylanish trombektomiya yoki aterektomiya tizimi yuqori tezlik burrs to maydalash yoki kalsifikatsiyalangan blyashka olib tashlang, bu stentni joylashtirish uchun lümenning yaxshi kengayishini ta'minlaydi.
-

Hero qo'rg'oshinni mexanik olib tashlash tizimi
BatafsilA mexanik alternative for lead extraction, employing specialized locking stylets or sheaths to dislodge fibrotic attachments, ensuring steady traction for safe removal.
-

Video Laryngoscope
BatafsilBardoshli, biomos keluvchi materiallardan tayyorlangan yuqori aniqlikdagi tibbiy asbob intubatsiya paytida havo yo'lini yaxshi ko'rishni ta'minlash, havo yo'llarini boshqarish protseduralarida xavfsizlik va samaradorlikni oshirish uchun mo'ljallangan.
-

Atlas koronar stent greft tizimi
BatafsilA qoplangan koronar stent tizim bilan ta'minlash ekstraluminal muhrlash teshiklar yoki psevdoanevrizmalar, ekstravazatsiyani oldini olishda koronar o'tkazuvchanlikni saqlash.
