AngioTEN Closure Device
A percutaneous vascular closure system for arterial yoki venoz access sites, enabling xavfsiz hemostasis after catheterization or interventional procedures.
AngioTEN Closure Device by INVAMED is a cyanoacrylate-based closure system designed to seal and stabilize the access site after angiographic procedures. Equipped with a specialized applicator, it ensures precise and user-friendly application of the adhesive over vascular puncture sites, reducing bleeding complications and enhancing patient recovery. By combining rapid polymerization with a biocompatible formula, AngioTEN helps minimize pseudoaneurysm formation and shortens manual compression time—optimizing clinical workflow in catheterization labs.
Cyanoacrylate Adhesive Technology
Employs a fast-curing medical-grade cyanoacrylate that bonds rapidly to tissue edges, helping create a secure and durable seal at the arterial or venous puncture site.
Ergonomic Applicator
Features a slim, intuitive applicator that allows precise dropwise or thin-stripe application, ensuring minimal adhesive wastage and targeted closure even in narrow access points.
Rapid Hemostasis
By instantly sealing the puncture track, AngioTEN reduces the need for prolonged manual compression or adjunct compression devices, potentially improving patient comfort and catheter lab throughput.
Biocompatible & Safe
Formulated to minimize tissue irritation and promote natural healing processes. Ideal for radial or femoral access closure after diagnostic angiography or interventional procedures.
Reduced Risk of Complications
Stabilizing the access site lowers the incidence of hematoma, pseudoaneurysm, or AV fistula formation, supporting safer vascular interventions and quicker discharge protocols.
Qo'llash mumkin bo'lmagan holatlar
- Heavy calcification, severely diseased artery walls
- Uncontrolled bleeding or coagulopathy beyond standard care measures
- Infection at the puncture site
Mahsulot spetsifikatsiyalari
Spetsifikatsiya | Tafsilot / qiymat |
Mahsulot nomi | AngioTEN Closure Device |
Foydalanish maqsadi | Percutaneous vascular closure post-catheterization |
Closure Mechanism | Suture-mediated or collagen plug |
Applicable Access Sites | Femoral artery/vein up to 8F–10F introducer sizes |
Deployment Method | Single-step device insertion and anchor release |
Hemostasis Time | Typically < 1 minute post-deployment |
Sterillik | Steril, bir martalik |
Yaroqlilik muddati | ~2–3 years at 15–25 °C |
Buyurtma va o'lcham matritsasi
Access Size (F) | Closure Method | Deployment Steps | Mahsulot kodi |
5–8 | Collagen Plug | Single | ATN-CP-5-8-S |
5–8 | Suture-Mediated | Single | ATN-SM-5-8-S |
8–10 | Collagen Plug | Single | ATN-CP-8-10-S |
8–10 | Suture-Mediated | Single | ATN-SM-8-10-S |
O' turdagi mahsulotlar
-
Atlas Peripheral Stent System
BatafsilA robust peripheral stent platform designed for femoral, iliac, yoki popliteal lesions, ensuring adequate radial qo'llab-quvvatlash va low restenosis rates in PAD interventions.
-
Keeper endovaskulyar tuzoq
BatafsilA ko'p tsiklli uchun tuzoq izlash qurilmasi begona jism yoki emboliya qo'lga olish, ta'minlash xavfsiz jalb qilish va olib tashlash qon tomir lümenlerinden.
-
Lotus Yagona Lumen va Ikki Lumen (RX) PTCA Mikrokateteri
BatafsilMikrokateterlar uchun mo'ljallangan koronar yoki periferik lezyon kesishishi, bir yoki ikki lümenli konfiguratsiyalarni taklif qiladi yo'naltiruvchi simlar almashinuvi, kontrastli in'ektsiya, yoki subselektiv lezyonga kirish.
-
DolphinPro Support Catheter
BatafsilA crossing support catheter for complex peripheral or coronary lesions, featuring a reinforced shaft va hydrophilic coating to ease device delivery.