NeoAblate Yumuşak Doku ve Karaciğer için Tümör Ablasyon Probu
Minimal invaziv tümör ablasyonu için tasarlanmış hassas mühendislik ürünü bir cihaz, yumuşak doku ve karaciğer tümörlerini etkili bir şekilde tedavi etmek için kontrollü enerji sağlarken çevredeki sağlıklı dokuya verilen zararı en aza indirir.
NeoAblate bir advanced thermal ablation system engineered for predictable, repeatable destruction of soft tissue ve liver tumors. By combining multi-point temperature feedback, a scalable active heating elementve minimal incision demands, NeoAblate ensures hassas, real-time monitoring of ablation zones while prioritizing patient comfort ve operator workflow efficiency. With a single 18 gauge probe capable of adjustable lengths from 1–2.5 cm, NeoAblate simplifies tumor targeting in both CT ve MRI contexts—supporting effective, minimal invaziv procedures.
Temel Özellikler
Predictable, Repeatable Ablations
- Dynamic Thermal Feedback: Integrates multi-point temperature monitoring (via 1 thermocouple) for real-time updates, enabling clinicians to fine-tune energy delivery.
- Consistent Tissue Coagulation: Maintains a stable, uniform thermal field, helping to achieve thorough ablation margins and reduce the risk of recurrence.
Single 18 Gauge Cannula Probe
- Scalable Active Length (1–2.5 cm): The ablation zone can be adjusted to match tumor size or shape, minimizing damage to adjacent healthy tissue.
- Slim Handle Design: Supports easy navigation and manipulation under ultrasound, CTveya MRI guidance, especially beneficial for complex or deep-seated lesions.
Minimal Incision, No Soft Tissue Introducer Required
- Beveled Surgical Tip: Aids penetration of hard tumors with minimal trauma, limiting bleeding or post-procedure discomfort.
- Insertable Length Options: Available in 15 cm, 20 cmveya 25 cm to accommodate varying patient body habitus and tumor locations.
Multi-Modal Imaging Compatibility
- Fits Both CT and MRI Gantries: A low-profile design ensures safe, unhindered scanning, letting operators confirm probe placement in real time.
- Precise Localization: Facilitates accurate, image-guided ablation for improved oncological outcomes.
- Dynamic Thermal Feedback: Integrates multi-point temperature monitoring (via 1 thermocouple) for real-time updates, enabling clinicians to fine-tune energy delivery.
- Consistent Tissue Coagulation: Maintains a stable, uniform thermal field, helping to achieve thorough ablation margins and reduce the risk of recurrence.
- Scalable Active Length (1–2.5 cm): The ablation zone can be adjusted to match tumor size or shape, minimizing damage to adjacent healthy tissue.
- Slim Handle Design: Supports easy navigation and manipulation under ultrasound, CTveya MRI guidance, especially beneficial for complex or deep-seated lesions.
- Beveled Surgical Tip: Aids penetration of hard tumors with minimal trauma, limiting bleeding or post-procedure discomfort.
- Insertable Length Options: Available in 15 cm, 20 cmveya 25 cm to accommodate varying patient body habitus and tumor locations.
- Fits Both CT and MRI Gantries: A low-profile design ensures safe, unhindered scanning, letting operators confirm probe placement in real time.
- Precise Localization: Facilitates accurate, image-guided ablation for improved oncological outcomes.
Klinik Avantajlar ve Uygulamalar
Soft Tissue & Hepatic Tumors
- Ideal for Primary & Metastatic Lesions: Ablation is effective for liver tumors or other soft tissue malignancies in subcutaneous or intramuscular sites.
- Tissue Preservation: Focused heat confines the ablation zone around the tumor, sparing healthy parenchyma.
Less Surgical Trauma & Faster Recovery
- Minimal Access: A single 18 G insertion path can significantly reduce hospital stays, postoperative pain, or complications.
- Outpatient Potential: Some smaller lesions might be managed with sedation and local anesthesia, freeing up OR time and resources.
Efficient & Safe Procedure Flow
- Power Settings up to 40 W: Default target temperature ranges (80–110 °C) allow consistent, thorough ablation coverage.
- Warning & Monitoring Systems: Audible and light signals alert the operator to high/low temperature or extended ablation times, ensuring immediate corrective action if needed.
Enhanced Operator Confidence
- Real-Time Temperature Feedback: Minimizes overtreatment or incomplete ablation, standardizing the ablation zone.
- Ergonomic Stability: Slim handle and multiple insertable lengths ensure stable needle control even in challenging anatomies.
- Ideal for Primary & Metastatic Lesions: Ablation is effective for liver tumors or other soft tissue malignancies in subcutaneous or intramuscular sites.
- Tissue Preservation: Focused heat confines the ablation zone around the tumor, sparing healthy parenchyma.
- Minimal Access: A single 18 G insertion path can significantly reduce hospital stays, postoperative pain, or complications.
- Outpatient Potential: Some smaller lesions might be managed with sedation and local anesthesia, freeing up OR time and resources.
- Power Settings up to 40 W: Default target temperature ranges (80–110 °C) allow consistent, thorough ablation coverage.
- Warning & Monitoring Systems: Audible and light signals alert the operator to high/low temperature or extended ablation times, ensuring immediate corrective action if needed.
- Real-Time Temperature Feedback: Minimizes overtreatment or incomplete ablation, standardizing the ablation zone.
- Ergonomic Stability: Slim handle and multiple insertable lengths ensure stable needle control even in challenging anatomies.