Mantis CURVE Over-the-Wire (OTW) Rotasyonel Farmakomekanik Trombektomi Sistemi

Bir tel üzerinden (OTW) cihaz birleştirme rotasyonel ile bozulma farmakolojik lizis, sağlıklı damar duvarlarını korurken büyük trombüsleri etkili bir şekilde temizler.

Rotational Pharmacomechanical Thrombectomy
  • Venturi Effect Mechanism: As the active tip spins within the vessel lumen, a hydrodynamic vortex forms, enabling targeted fragmentation and aspiration of the thrombus.
  • Drug Infusion Port: Concurrent infusion of anti-thrombolytic agents ensures cohesive mixing with the thrombus, expediting clot dissolution and clearance.
  • Coil Design: The sinusoidal wave geometry, visible from the distal tip to proximal region, efficiently engages and fragments clot.
  • Preventing Distal Embolism: The rotational vortex action, combined with controlled drug release, helps retain clot particles in proximity for prompt removal, reducing the risk of distal migration.
  • 0.035” Guidewire Compatibility: Simplifies wire management in complex anatomies (including tortuous or large-diameter vessels).
  • Catheter Lengths: With 90 cm and 110 cm functional lengths, and 120 cm or 135 cm profiles, the system accommodates an array of procedural approaches.
  • 5.0F to 8.0F: Offers suitable sizing for broad vessel diameters in the peripheral venous circulation, pulmonary artery, or IVC.
  • Radiopaque: The braided shaft is visible under fluoroscopy from distal tip to proximal segment, aiding real-time device positioning.
  • Low-Friction Catheter Lumen: Streamlines guidewire passage and drug infusion, helping avoid clot or tissue adherence to the catheter walls.
  • Reduced Shear Stress: Minimizes friction on vessel endothelium, supporting safer navigation in high-stakes procedures.

Ürün Özellikleri

Şartname Detay / Değer
Ürün Adı Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System
Kullanım Amacı Combined mechanical disruption + lytic infusion for acute/subacute thrombosis in peripheral or venous systems
Kateter Tasarımı Over-the-wire shaft with curved rotational tip for enhanced clot contact, integrated infusion port
Rotational Speed Range ~40k–80k rpm (verify final)
Infusion Mechanism Side port or multi-hole segment for tPA or lytic agent delivery
Dış Çap (F) ~5–7F, depending on model
Çalışma Uzunluğu ~80–120 cm (varies by product code)
Kılavuz Tel Uyumluluğu Typically 0.035” (OTW approach)
Sterilite Steril, Tek Kullanımlık
Raf Ömrü Kapalı ambalajda 15-25 °C'de ~2-3 yıl
Klinik Endikasyonlar Deep venous thrombosis (DVT), acute peripheral arterial occlusions, possibly for pulmonary thrombosis (per label)
Kontrendikasyonlar Extremely tortuous vessels, heavy calcification, or known device material allergies

Sipariş ve Boyut Matrisi

Dış Çap (F) Çalışma Uzunluğu (cm) Curve Tip Configuration Ürün Kodu Notlar
5F 80 Moderate Curve MNT-CV-5F-80-MC Smaller lumen, shorter approach
5F 100 Deep Curve MNT-CV-5F-100-DC Extended shaft, deeper curve for better clot contact
6F 80 Moderate Curve MNT-CV-6F-80-MC Common size for peripheral thrombectomy
6F 120 Deep Curve MNT-CV-6F-120-DC Extended length with advanced curve tip
7F 100 Moderate Curve MNT-CV-7F-100-MC Larger lumen for heavier clot burden
7F 120 Deep Curve MNT-CV-7F-120-DC Max length, enhanced curve for extensive occlusions