Atlas Endovascular Peripheral Stent Graft
A covered peripheral stent graft offering безопасный occlusion of aneurysms or occlusive lesions in подвздошная кость или бедренная кость segments, reducing risk of rupture or re-occlusion.
Reinforced Stability, Unparalleled Durability
Elevate Vascular Repair with the Power of Carbon:
• Durability: The carbon coating adds an extra layer of strength and resilience. • Biocompatibility: Designed to minimize irritation and promote faster recovery. • Radiopacity: Enhanced visibility under imaging for precise placement.
Precision, Protection, Performance:
SIGNIFICANT ADVANCEMENT IN ENDOVASCULAR REPAIR TECHNOLOGY
ENHANCED WITH A ROBUST CARBON COATING OPTIMIZED FOR BOTH FLEXIBILITY AND CONFORMABILITY
Self-Expanding Nitinol Framework
- Shape-Memory Alloy: Nitinol’s superelastic properties enable consistent radial force to maintain stent apposition, conforming effectively to vessel anatomies.
- Tantalum Markings: Both stent ends include tantalum markers, providing high radiopacity for precise positioning under fluoroscopy.
Microporous ePTFE Graft Material
- Sealing Function: The ePTFE covering excludes blood flow from the aneurysmal or diseased arterial wall, helping reduce the risk of endoleaks.
- Biocompatible & Low Profile: The microporous structure supports healing while limiting inflammatory responses.
Single-Stent Design
- Straightforward Implantation: Simplifies device selection and deployment, particularly beneficial in peripheral lesions requiring a single stent graft solution.
- Enhanced Device Integrity: Minimizes potential junctional leak points or component separations sometimes encountered in multi-piece stent systems.
Carbon Surface Coating
- Thromboresistant: The carbon coating on the stent struts aims to reduce platelet adhesion, promoting stable device integration and lower incidence of thrombosis.
- Smooth Flow Lumen: Enhances hemodynamic compatibility and may further limit intimal hyperplasia.
Wide Diameter and Length Range
- Stent Graft Size: 5.0 to 10.0 mm diameters address multiple peripheral vessel diameters.
- Nominal Stent Graft Length: Ranging from 18 to 58 mm in designated sizes (18, 22, 28, 38, 58 or 18, 23, 27, 37, 57)—covering a broad spectrum of lesion lengths.
Общие характеристики продукции
| Технические характеристики | Деталь / Значение |
| Название продукта | Atlas Endovascular Stent Graft |
| Предполагаемое использование | Endovascular repair of peripheral aneurysms, arterial occlusive disease, or traumatic injuries (iliac, femoral, popliteal) |
| Graft Material | ePTFE covering over metal scaffold |
| Scaffold Material | Nitinol (self-expanding depending on design) |
| Deployment Method | Over-the-wire with introducer sheath (commonly 14F–18F, depending on stent diameter) |
| Радиальная сила | Medium-High, ensuring stable vessel wall apposition |
| Delivery Shaft Length | Typically 80–120 cm (verify exact product specs) |
| Радиоактивные маркеры | Proximal and distal markers to guide accurate placement |
| Стерильность | Стерильный (оксид этилена) |
| Одноразовое использование | Да |
| Срок годности | ~3–5 years if stored at 15–25 °C in sealed packaging |
| Совместимость MR | MR Conditional (verify labeling) |
| Клинические показания | Peripheral artery aneurysms (iliac, femoral), endoluminal bridging for traumatic or pseudoaneurysms, possible bypass for occlusive lesions |
| Противопоказания | Extremely calcified or tortuous vessels preventing safe device passage, known nickel or metal allergies |
Atlas Endovascular Stent Graft
| Диаметр (мм) | Длина (мм) | Размер ножен (F) | Код товара | Примечания |
| 6 | 40 | ~14F | AESG-6x40 | Small diameter for distal external iliac or femoral |
| 6 | 60 | ~14F | AESG-6x60 | |
| 6 | 80 | ~14F | AESG-6x80 | |
| 7 | 40 | ~14F | AESG-7x40 | Slightly larger for moderate-sized arteries |
| 7 | 80 | ~14F | AESG-7x80 | |
| 7 | 100 | ~14F | AESG-7x100 | |
| 8 | 60 | ~14–16F | AESG-8x60 | Common size for iliac region |
| 8 | 80 | ~14–16F | AESG-8x80 | |
| 8 | 120 | ~16F | AESG-8x120 | Longer coverage for extensive lesion |
| 9 | 60 | ~16F | AESG-9x60 | For large external iliac or superficial femoral |
| 9 | 100 | ~16F | AESG-9x100 | |
| 9 | 150 | ~16F | AESG-9x150 | Extended length for multi-segment disease |
| 10 | 60 | ~16–18F | AESG-10x60 | Larger diameter for bigger femoral or proximal arteries |
| 10 | 120 | ~18F | AESG-10x120 | |
| 10 | 150 | ~18F | AESG-10x150 | |
| 12 | 80 | ~18F | AESG-12x80 | Very large diameter bridging aneurysms |
| 12 | 100 | ~18F | AESG-12x100 | |
| 12 | 150 | ~18F | AESG-12x150 | Maximum coverage for extensive peripheral disease |
| 12 | 200 | ~18F | AESG-12x200 | Very long stent graft for special cases |
Похожие товары
-

Extender Баллонный катетер для ПТКА с лекарственной элюминацией Паклитаксел
ПодробнееA покрытые паклитакселом коронарный баллонный катетер, направленный на уменьшение рестеноза во время чрескожной транслюминальной коронарной ангиопластики (ЧТКА), обеспечивая эффективную доставку лекарств к стенке сосуда.
-

Dolphin Sub-Intimal Entry Catheter
ПодробнееA sub-intimal entry system aiding re-entry into the true lumen after sub-intimal crossing in CTO or heavily occluded segments, ensuring minimal dissection expansions.
-

SteerCATH Управляемый катетер
ПодробнееA управляемый поддерживайте катетер с помощью отклоняемый Наконечник, предназначенный для сложных или ветвистый сосуд доступа при коронарных и периферических вмешательствах. Повышает успешность пересечения сложных анатомических образований.
-

Периферическая стент-система Atlas
ПодробнееПрочный периферический стент платформа, разработанная для бедренная кость, подвздошная кость, или поплитэя поражения, обеспечивая адекватный радиальная опора и низкий частота рестенозов при вмешательствах на ПАД.
Контакты и поддержка
Чем мы можем помочь?
Прежде чем мы начнем, скажите, что лучше всего характеризует вас?
Контакты и поддержка
Профессионалы здравоохранения
Форма онлайн-запроса
Для получения общих вопросов или вопросов, связанных с продукцией, заполните нашу быструю онлайн-форму. Вы получите подтверждение и контрольный номер для отслеживания.
Запросы по продукции
Поддержка клинических и научных исследований
Обучение и образование
Техническая поддержка
Контакты и поддержка
Пациент и лица, осуществляющие уход
Форма онлайн-запроса
Для получения общих вопросов или вопросов, связанных с продукцией, заполните нашу быструю онлайн-форму. Вы получите подтверждение и контрольный номер для отслеживания.
Использование и безопасность продукта
Заказ и оплата
Поддержка и последующий уход
Контакты и поддержка
Поставщики и дистрибьюторы
Форма онлайн-запроса
Для получения общих вопросов или вопросов, связанных с продукцией, заполните нашу быструю онлайн-форму. Вы получите подтверждение и контрольный номер для отслеживания.
Партнерство и контракты
Логистика и судоходство
Соответствие требованиям и документация
Контакты и поддержка
Поставщики и дистрибьюторы
Форма онлайн-запроса
Для получения общих вопросов или вопросов, связанных с продукцией, заполните нашу быструю онлайн-форму. Вы получите подтверждение и контрольный номер для отслеживания.
Пресс-релизы и новости
Интервью и заявления
События и конференции
Контакты и поддержка
Прочее / Общие вопросы
Форма онлайн-запроса
Для получения общих вопросов или вопросов, связанных с продукцией, заполните нашу быструю онлайн-форму. Вы получите подтверждение и контрольный номер для отслеживания.
Общая информация
Отзывы и предложения
Линия поддержки HeadQuarter
- One World Trade Center, 285 Fulton Street. Нью-Йорк, штат Нью-Йорк, 10007, США
- globalsales@invamed.com
- +1(669)248-1675
