Dispositivo de fecho AngioTEN
A percutânea sistema de fecho vascular para arterial ou venoso sítios de acesso, permitindo seguro hemostasia após cateterização ou procedimentos de intervenção.
AngioTEN Closure Device by INVAMED is a cyanoacrylate-based closure system designed to seal and stabilize the access site after angiographic procedures. Equipped with a specialized applicator, it ensures precise and user-friendly application of the adhesive over vascular puncture sites, reducing bleeding complications and enhancing patient recovery. By combining rapid polymerization with a biocompatible formula, AngioTEN helps minimize pseudoaneurysm formation and shortens manual compression time—optimizing clinical workflow in catheterization labs.
Cyanoacrylate Adhesive Technology
Employs a fast-curing medical-grade cyanoacrylate that bonds rapidly to tissue edges, helping create a secure and durable seal at the arterial or venous puncture site.
Ergonomic Applicator
Features a slim, intuitive applicator that allows precise dropwise or thin-stripe application, ensuring minimal adhesive wastage and targeted closure even in narrow access points.
Rapid Hemostasis
By instantly sealing the puncture track, AngioTEN reduces the need for prolonged manual compression or adjunct compression devices, potentially improving patient comfort and catheter lab throughput.
Biocompatible & Safe
Formulated to minimize tissue irritation and promote natural healing processes. Ideal for radial or femoral access closure after diagnostic angiography or interventional procedures.
Reduced Risk of Complications
Stabilizing the access site lowers the incidence of hematoma, pseudoaneurysm, or AV fistula formation, supporting safer vascular interventions and quicker discharge protocols.
Contra-indicações
- Heavy calcification, severely diseased artery walls
- Uncontrolled bleeding or coagulopathy beyond standard care measures
- Infection at the puncture site
Especificações do produto
| Especificação | Detalhe / Valor |
| Nome do produto | Dispositivo de fecho AngioTEN |
| Utilização prevista | Percutaneous vascular closure post-catheterization |
| Closure Mechanism | Suture-mediated or collagen plug |
| Applicable Access Sites | Femoral artery/vein up to 8F–10F introducer sizes |
| Deployment Method | Single-step device insertion and anchor release |
| Hemostasis Time | Typically < 1 minute post-deployment |
| Esterilidade | Estéril, de utilização única |
| Prazo de validade | ~2–3 years at 15–25 °C |
Matriz de tamanhos e encomendas
| Access Size (F) | Closure Method | Deployment Steps | Código do produto |
| 5–8 | Collagen Plug | Single | ATN-CP-5-8-S |
| 5–8 | Suture-Mediated | Single | ATN-SM-5-8-S |
| 8–10 | Collagen Plug | Single | ATN-CP-8-10-S |
| 8–10 | Suture-Mediated | Single | ATN-SM-8-10-S |
Produtos Relacionados
-

Laço endovascular Keeper
Ler maisA multi-loop dispositivo de recolha de laços para corpo estranho ou embolo captura, assegurando seguro empenhamento e retirada dos lúmens vasculares.
-

Sistema mecânico de remoção de chumbo Hero
Ler maisA mecânico alternativa para extração de chumboutilizando estiletes ou bainhas de bloqueio especializadas para deslocar anexos fibróticos, assegurando estável tração para uma remoção segura.
-

Nexus Cânula venosa e arterial
Ler maisPolivalente venoso e arterial cânulas de suporte circulação extracorporal durante o bypass cardiopulmonar ou ECMO, assegurando uma caudais e hemocompatibilidade.
-

Cateter de suporte DolphinPro