Dispositivo de fecho AngioTEN
A percutânea sistema de fecho vascular para arterial ou venoso sítios de acesso, permitindo seguro hemostasia após cateterização ou procedimentos de intervenção.
AngioTEN Closure Device by INVAMED is a cyanoacrylate-based closure system designed to seal and stabilize the access site after angiographic procedures. Equipped with a specialized applicator, it ensures precise and user-friendly application of the adhesive over vascular puncture sites, reducing bleeding complications and enhancing patient recovery. By combining rapid polymerization with a biocompatible formula, AngioTEN helps minimize pseudoaneurysm formation and shortens manual compression time—optimizing clinical workflow in catheterization labs.
Cyanoacrylate Adhesive Technology
Employs a fast-curing medical-grade cyanoacrylate that bonds rapidly to tissue edges, helping create a secure and durable seal at the arterial or venous puncture site.
Ergonomic Applicator
Features a slim, intuitive applicator that allows precise dropwise or thin-stripe application, ensuring minimal adhesive wastage and targeted closure even in narrow access points.
Rapid Hemostasis
By instantly sealing the puncture track, AngioTEN reduces the need for prolonged manual compression or adjunct compression devices, potentially improving patient comfort and catheter lab throughput.
Biocompatible & Safe
Formulated to minimize tissue irritation and promote natural healing processes. Ideal for radial or femoral access closure after diagnostic angiography or interventional procedures.
Reduced Risk of Complications
Stabilizing the access site lowers the incidence of hematoma, pseudoaneurysm, or AV fistula formation, supporting safer vascular interventions and quicker discharge protocols.
Contra-indicações
- Heavy calcification, severely diseased artery walls
- Uncontrolled bleeding or coagulopathy beyond standard care measures
- Infection at the puncture site
Especificações do produto
Especificação | Detalhe / Valor |
Nome do produto | Dispositivo de fecho AngioTEN |
Utilização prevista | Percutaneous vascular closure post-catheterization |
Closure Mechanism | Suture-mediated or collagen plug |
Applicable Access Sites | Femoral artery/vein up to 8F–10F introducer sizes |
Deployment Method | Single-step device insertion and anchor release |
Hemostasis Time | Typically < 1 minute post-deployment |
Esterilidade | Estéril, de utilização única |
Prazo de validade | ~2–3 years at 15–25 °C |
Matriz de tamanhos e encomendas
Access Size (F) | Closure Method | Deployment Steps | Código do produto |
5–8 | Collagen Plug | Single | ATN-CP-5-8-S |
5–8 | Suture-Mediated | Single | ATN-SM-5-8-S |
8–10 | Collagen Plug | Single | ATN-CP-8-10-S |
8–10 | Suture-Mediated | Single | ATN-SM-8-10-S |
Produtos Relacionados
-
Stena Modulador de fluxo multi-camada para periféricos
Ler maisDesvio de fluxo stent para periférico artérias, redistribuindo laminar fluxo para longe dos segmentos de vasos doentes, ajudando na preservação de aneurismas ou ramos laterais.
-
Sistema de Aterectomia Periférica TemREN
Ler maisA rotacional ou direcional dispositivo de aterectomia especializado para excisão da placa nas artérias periféricas, aumentando lúmen restauração, minimizando o barotrauma.
-
Cateter dirigível SteerCATH
Ler maisA orientável cateter de suporte com deflectível ponta, concebida para aplicações complexas ou vaso de derivação acesso em intervenções coronárias e periféricas. Aumenta o sucesso do cruzamento em anatomias difíceis.
-
Sistema de stent periférico Atlas
Ler maisUm robusto stent periférico plataforma concebida para femoral, ilíaco, ou poplítea lesões, assegurando adequado suporte radial e baixo taxas de reestenose em intervenções na DAP.