Sistema de stent coronário com eluição de fármacos ATLAS Crómio-cobalto
A cobalto-crómio colocação de stent coronário resistência radial duradoura e excelente rastreabilidadeadequado para complexo ou calcificado lesões coronárias, assegurando simultaneamente um recuo mínimo.
O ATLAS Drug Eluting Coronary Stent System is a next-generation cobalt-chromium (CoCr) stent platform coated with a sirolimus formulation (1 µg/mm²) designed to reduce restenosis in patients with coronary artery disease. By combining advanced laser-cutting technology and a clinically proven antiproliferative drug, the ATLAS system delivers durable vessel patency and a high safety profile in both de novo lesions and in-stent restenosis scenarios.
Cobalt-Chromium Alloy (L605) Construction
- Ensures exceptional strength-to-thickness ratio, enabling thinner struts without compromising radial force.
- Exhibits excellent corrosion resistance and biocompatibility for a stable healing environment.
Laser-Cut Stent Design
- Precision machining yields consistent strut geometry, promoting uniform drug distribution and an even healing surface along the vessel wall.
- Enhances stent deliverability, allowing smooth passage through calcified or tortuous coronary segments.
Sirolimus Elution Profile
- 1 µg/mm² of sirolimus is coated onto the stent’s surface, ensuring a sustained, controlled release that minimizes in-stent neointimal growth.
- Controlled drug release aids in rapid endothelialization, lowering the risk of late stent thrombosis.
Radiopaque Pt-Ir Markers
- Platinum-iridium markers at stent edges enable precise visibility under fluoroscopy.
- Facilitates accurate positioning during percutaneous coronary intervention (PCI) procedures.
High-Pressure Capability
interventional cardiologists flexibility to optimize stent expansion based on lesion complexity.
| Especificação | Detalhe / Valor |
| Nome do produto | Atlas Coronary Stent (Cobalt Chromium) |
| Stent Type | Balloon-Expandable Coronary Stent |
| Material | Cobalt-Chromium Alloy |
| Strut Thickness | ~80 µm (typical) |
| Conceção | Open-cell or hybrid-cell architecture (depending on exact model) |
| Nominal Pressure (NP) | 9–10 atm |
| Rated Burst Pressure (RBP) | ~14–16 atm |
| Stent Delivery System | Rapid-Exchange (RX) or Over-the-Wire (OTW), typically 140 cm shaft length |
| Compatibilidade de fios-guia | 0.014” |
| Stent Surface | Bare-metal or optional drug-eluting polymer (if applicable) |
| Indicações | Coronary artery lesion scaffolding, single or multivessel disease, potential usage in small/medium/large vessels |
| Contra-indicações | Lesions unsuited for balloon-expandable stent therapy (e.g., severely calcified, left main trunk, etc.), or as per physician discretion |
| Esterilidade | Estéril (Óxido de Etileno) |
| Utilização única | Sim |
| Prazo de validade | 2–3 years (depending on final packaging and polymer, if any) |
| Temperatura de funcionamento | Recommended 15–25 °C for storage |
Encomenda detalhada com base no tamanho e códigos de produto
| Stent Diameter (mm) | Stent Length (mm) | Nominal Pressure (atm) | RBP (atm) | Código do produto |
| 2.00 | 8 | 9 | 14 | ATLS-CC-2.00x08 |
| 2.00 | 12 | 9 | 14 | ATLS-CC-2.00x12 |
| 2.00 | 15 | 9 | 14 | ATLS-CC-2.00x15 |
| 2.00 | 18 | 10 | 16 | ATLS-CC-2.00x18 |
| 2.00 | 24 | 10 | 16 | ATLS-CC-2.00x24 |
| 2.00 | 28 | 10 | 16 | ATLS-CC-2.00x28 |
| 2.00 | 32 | 10 | 16 | ATLS-CC-2.00x32 |
| 2.00 | 38 | 10 | 16 | ATLS-CC-2.00x38 |
| 2.25 | 8 | 9 | 14 | ATLS-CC-2.25x08 |
| 2.25 | 12 | 9 | 14 | ATLS-CC-2.25x12 |
| 2.25 | 15 | 9 | 14 | ATLS-CC-2.25x15 |
| 2.25 | 18 | 10 | 16 | ATLS-CC-2.25x18 |
| 2.25 | 24 | 10 | 16 | ATLS-CC-2.25x24 |
| 2.25 | 28 | 10 | 16 | ATLS-CC-2.25x28 |
| 2.25 | 32 | 10 | 16 | ATLS-CC-2.25x32 |
| 2.25 | 38 | 10 | 16 | ATLS-CC-2.25x38 |
| 2.50 | 8 | 9 | 14 | ATLS-CC-2.50x08 |
| 2.50 | 12 | 9 | 14 | ATLS-CC-2.50x12 |
| 2.50 | 15 | 9 | 14 | ATLS-CC-2.50x15 |
| 2.50 | 18 | 10 | 16 | ATLS-CC-2.50x18 |
| 2.50 | 24 | 10 | 16 | ATLS-CC-2.50x24 |
| 2.50 | 28 | 10 | 16 | ATLS-CC-2.50x28 |
| 2.50 | 32 | 10 | 16 | ATLS-CC-2.50x32 |
| 2.50 | 38 | 10 | 16 | ATLS-CC-2.50x38 |
| 2.75 | 8 | 9 | 14 | ATLS-CC-2.75x08 |
| 2.75 | 12 | 9 | 14 | ATLS-CC-2.75x12 |
| 2.75 | 15 | 9 | 14 | ATLS-CC-2.75x15 |
| 2.75 | 18 | 10 | 16 | ATLS-CC-2.75x18 |
| 2.75 | 24 | 10 | 16 | ATLS-CC-2.75x24 |
| 2.75 | 28 | 10 | 16 | ATLS-CC-2.75x28 |
| 2.75 | 32 | 10 | 16 | ATLS-CC-2.75x32 |
| 2.75 | 38 | 10 | 16 | ATLS-CC-2.75x38 |
| 3.00 | 8 | 9 | 14 | ATLS-CC-3.00x08 |
| 3.00 | 12 | 9 | 14 | ATLS-CC-3.00x12 |
| 3.00 | 15 | 9 | 14 | ATLS-CC-3.00x15 |
| 3.00 | 18 | 10 | 16 | ATLS-CC-3.00x18 |
| 3.00 | 24 | 10 | 16 | ATLS-CC-3.00x24 |
| 3.00 | 28 | 10 | 16 | ATLS-CC-3.00x28 |
| 3.00 | 32 | 10 | 16 | ATLS-CC-3.00x32 |
| 3.00 | 38 | 10 | 16 | ATLS-CC-3.00x38 |
| 3.25 | 12 | 9 | 14 | ATLS-CC-3.25x12 |
| 3.25 | 15 | 9 | 14 | ATLS-CC-3.25x15 |
| 3.25 | 18 | 10 | 16 | ATLS-CC-3.25x18 |
| 3.25 | 24 | 10 | 16 | ATLS-CC-3.25x24 |
| 3.25 | 28 | 10 | 16 | ATLS-CC-3.25x28 |
| 3.25 | 32 | 10 | 16 | ATLS-CC-3.25x32 |
| 3.25 | 38 | 10 | 16 | ATLS-CC-3.25x38 |
| 3.50 | 8 | 9 | 14 | ATLS-CC-3.50x08 |
| 3.50 | 12 | 9 | 14 | ATLS-CC-3.50x12 |
| 3.50 | 15 | 9 | 14 | ATLS-CC-3.50x15 |
| 3.50 | 18 | 10 | 16 | ATLS-CC-3.50x18 |
| 3.50 | 24 | 10 | 16 | ATLS-CC-3.50x24 |
| 3.50 | 28 | 10 | 16 | ATLS-CC-3.50x28 |
| 3.50 | 32 | 10 | 16 | ATLS-CC-3.50x32 |
| 3.50 | 38 | 10 | 16 | ATLS-CC-3.50x38 |
| 4.00 | 8 | 9 | 14 | ATLS-CC-4.00x08 |
| 4.00 | 12 | 9 | 14 | ATLS-CC-4.00x12 |
| 4.00 | 15 | 9 | 14 | ATLS-CC-4.00x15 |
| 4.00 | 18 | 10 | 16 | ATLS-CC-4.00x18 |
| 4.00 | 24 | 10 | 16 | ATLS-CC-4.00x24 |
| 4.00 | 28 | 10 | 16 | ATLS-CC-4.00x28 |
| 4.00 | 32 | 10 | 16 | ATLS-CC-4.00x32 |
| 4.00 | 38 | 10 | 16 | ATLS-CC-4.00x38 |
Produtos Relacionados
-

Stena Modulador de fluxo multi-camada para periféricos
Ler maisDesvio de fluxo stent para periférico artérias, redistribuindo laminar fluxo para longe dos segmentos de vasos doentes, ajudando na preservação de aneurismas ou ramos laterais.
-

Atlas Endovascular Peripheral Stent Graft (Endovascular Peripheral Stent Graft)
Ler maisA stent periférico revestido oferta de enxertos seguro oclusão de aneurismas ou lesões oclusivas em ilíaco ou femoral segmentos, reduzindo o risco de rutura ou reoclusão.
-

Dispositivo de fecho AngioTEN
Ler maisA percutânea sistema de fecho vascular para arterial ou venoso sítios de acesso, permitindo seguro hemostasia após cateterização ou procedimentos de intervenção.
-

Sistema mecânico de remoção de chumbo Hero
Ler maisA mecânico alternativa para extração de chumboutilizando estiletes ou bainhas de bloqueio especializadas para deslocar anexos fibróticos, assegurando estável tração para uma remoção segura.