Peta
Sternum Closure Plate


The new standard in primary closure

Peta Sternal Closure plates' thinner and anatomical design help address the challenges associated with fixating a 90-degree sternal incision or rib osteotomy. The plates increase stability at the osteotomy site, while still allowing for minimally invasive access.


Share

A Low Profile Locking Block Made Of Highly Biocompatible (TI-6AL-4V-ELI) Alloy Is Used

  • MR compatible.
  • There is no risk of self-loosening or opening after the locking block is fixed by screwing.
  • During the procedure, the screw of the locking block is loosened, allowing re-tensioning, shortening the operating room time.
  • The figure preffered by the surgeon can be applied.

They are the products used to fix the fracture in the bone in cases where stable fixation is required in the treatment of accidental fractures in the bones of the human skeleton or the treatment of congenital deformities. Invamed Cytronics Locked Sternal Plates are for use in stabilizing and fixing fractures to aid in alignment and stabilization of bone in anterior chest wall fractures, including sternal fixation after sternotomy and after sternal reconstructive surgical procedures. Instrumentation is indicated for use in this implant system.

Detailed specifications

Peta is intended for use in the stabilization and fixation of fractures of the anterior chest wall including sternal fixation following sternotomy and sternal reconstructive surgical procedures, to promote fusion.

Every year, over one million people worldwide undergo open-heart surgery in the fight against cardiovascular disease.

Peta Sternal Closure System applies the proven principles of locking rigid fixation to sternal closure and offers a rigid fixation alternative for mid-line sternotomies as well as a variety of minimally invasive approaches including the mini-sternotomy and mini-thoracotomy.

Peta ternal Closure plate's thinner and anatomical design help address the challenges associated with fixating a 90-degree sternal incision or rib osteotomy. The plates increase stability at the osteotomy site, while still allowing for minimally invasive access.

Benefits of Rigid Fixation

  • Increased stability
  • Greater strength
  • Reduced sternal separation
  • Superior bone healing
  • Reduced pain and narcotic usage

Features of the Peta ternal Closure System

  • Rigid fixation system for use following sternotomy or sternal reconstructive procedures
  • Patent-pending cuttable cross-sections for emergent re-entry
  • Uniquely designed thin plates for anatomical fit
  • Cancellous screws designed for the sternum
  • Specially designed instrumentation

 

A Low Profile Locking Block Made Of Highly Biocompatible (TI-6AL-4V-ELI) Alloy Is Used

  • MR compatible.
  • There is no risk of self-loosening or opening after the locking block is fixed by screwing.
  • During the procedure, the screw of the locking block is loosened, allowing re-tensioning, and shortening the operating room time.
  • The figure preferred by the surgeon can be applied.
Order Number Material Holes Design
CR1049 TI-6AL-4V-ELI 5 Straight
CR1050 TI-6AL-4V-ELI 6 Straight
CR1051 TI-6AL-4V-ELI 7 Straight
CR1052 TI-6AL-4V-ELI 8 Straight
CR1053 TI-6AL-4V-ELI 9 Straight
CR1054 TI-6AL-4V-ELI 10 Straight
CR1055 TI-6AL-4V-ELI 11 Straight
CR1056 TI-6AL-4V-ELI 12 Straight
CR1057 TI-6AL-4V-ELI 5 Angled
CR1058 TI-6AL-4V-ELI 6 Angled
CR1059 TI-6AL-4V-ELI 7 Angled
CR1060 TI-6AL-4V-ELI 8 Angled
CR1061 TI-6AL-4V-ELI 9 Angled
CR1062 TI-6AL-4V-ELI 10 Angled
CR1063 TI-6AL-4V-ELI 11 Angled
CR1064 TI-6AL-4V-ELI 12 Angled