Mantis XP Thrombectomy System for Fistula
A high-powered mechanical thrombectomy device for deep venous or arterial occlusions, supporting extended reach and robust clot extraction in complex anatomies.
그리고 Mantis XP 는 pharmacomechanical thrombectomy system specifically engineered for dialysis native AV fistulae. Featuring a 회전 catheter design and sinusoidal wave geometry, Mantis XP enables rapid 그리고 efficient clot disruption, infusion, and evacuation in a single pass—helping to restore patency while 최소화 potential vessel trauma in end-stage renal disease (ESRD) patients requiring continuous dialysis access.
Rotational Thrombectomy Mechanism
- Sinusoidal Wave Shape: The unique sinusoidal wire design translates rotational energy into targeted clot fragmentation, limiting stress on native fistula walls.
- Pharmacomechanical Combination: Simultaneously administers lytic agents (if required) via the infusion zone, accelerating clot dissolution and removal.
Extended Infusion Zone
- 10 cm from Distal Tip: Delivers thrombolytic or flushing solutions directly to the lesion area, optimizing pharmacologic contact with the clot.
- Efficient Local Drug Delivery: Improves clot breakdown while minimizing systemic agent usage.
Variable Catheter Length & Profile
- 길이: 30 cm, 45 cm, 90 cm, 110 cm provide flexibility for short or extended vascular access routes—particularly relevant for complex fistula anatomies.
- Profiles: 5.0F–7.0F outer diameters suit different vessel sizes, ensuring robust torque transmission and navigability.
Nitinol & PA/PEBAX Construction
- Nitinol Core: Maintains shape integrity and provides kink resistance, critical in tortuous AV fistula segments.
- PTFE Inner Layer: Minimizes friction with guidewires and helps protect vessel surfaces during repeated manipulations.
Radiopacity & Visibility
- Braided Shaft: Allows real-time tracking under fluoroscopy, visible from the distal tip 를 proximal segment.
- 15 cm Active Zone: Clear identification ensures accurate lesion coverage and improved operator confidence.
- Sinusoidal Wave Shape: The unique sinusoidal wire design translates rotational energy into targeted clot fragmentation, limiting stress on native fistula walls.
- Pharmacomechanical Combination: Simultaneously administers lytic agents (if required) via the infusion zone, accelerating clot dissolution and removal.
- 10 cm from Distal Tip: Delivers thrombolytic or flushing solutions directly to the lesion area, optimizing pharmacologic contact with the clot.
- Efficient Local Drug Delivery: Improves clot breakdown while minimizing systemic agent usage.
- 길이: 30 cm, 45 cm, 90 cm, 110 cm provide flexibility for short or extended vascular access routes—particularly relevant for complex fistula anatomies.
- Profiles: 5.0F–7.0F outer diameters suit different vessel sizes, ensuring robust torque transmission and navigability.
- Nitinol Core: Maintains shape integrity and provides kink resistance, critical in tortuous AV fistula segments.
- PTFE Inner Layer: Minimizes friction with guidewires and helps protect vessel surfaces during repeated manipulations.
- Braided Shaft: Allows real-time tracking under fluoroscopy, visible from the distal tip 를 proximal segment.
- 15 cm Active Zone: Clear identification ensures accurate lesion coverage and improved operator confidence.
제품 사양
| 사양 | 세부 정보 / 값 |
| 제품 이름 | Mantis XP Thrombectomy System |
| 사용 목적 | High-powered mechanical thrombectomy in venous or arterial occlusions, removing large or organized clot |
| 카테터 디자인 | Rotational shaft with extended reach (“XP”), integrated aspiration lumen or side port |
| 재료 | Stainless steel or nitinol core, polymer outer sheath |
| Rotational Speed Range | ~50k–120k rpm (verify final) |
| 외경(F) | ~6–8F (depending on model) |
| 작업 길이 | ~80–120 cm (varies by product code) |
| 가이드 와이어 호환성 | Typically 0.035” |
| 무균 | 멸균, 일회용 |
| 유통 기한 | ~2–3 years if stored at 15–25 °C in sealed packaging |
| 임상 적응증 | Large clot burdens in major peripheral veins/arteries, deep venous thrombosis (DVT), acute limb ischemia |
| 금기 사항 | Extremely tortuous vessels, heavily calcified segments, or known sensitivity to device materials |
주문 및 사이즈 매트릭스
| 외경(F) | 작업 길이(cm) | 팁 구성 | 제품 코드 | 참고 |
| 6F | 80 | Standard Rotational Tip | MNT-XP-6F-80-SR | Smaller OD for moderate clot loads |
| 6F | 100 | Leaf Tip | MNT-XP-6F-100-LF | Intermediate length, specialized tip for large clot |
| 7F | 80 | Standard Rotational Tip | MNT-XP-7F-80-SR | Larger OD for heavier clot burden |
| 7F | 120 | Leaf Tip | MNT-XP-7F-120-LF | Extended shaft + specialized tip for extensive occlusions |
| 8F | 100 | Standard Rotational Tip | MNT-XP-8F-100-SR | Max diameter & high rotational power for dense clots |
| 8F | 120 | Leaf Tip | MNT-XP-8F-120-LF | Extended length + leaf tip for severe multi-segment thrombosis |
연관 상품
-

Venablock ™ 정맥류 치료 정맥 폐쇄 시스템
더 보기Venablock ™ 하지정맥류 치료 정맥 폐쇄 시스템; A 시아노아크릴레이트 기반 정맥 폐쇄 시스템 피상적 정맥 무능력, 전달 비열 최소 국소 마취를 통한 폐색 및 빠른 절차 후 복구.
-

VeinOFF 하지정맥류 치료제
더 보기전문화된 경화제 또는 접착제 공식은 비열 최소한의 마취와 짧은 시술 시간이 필요한 하지정맥류 제거술입니다.
-

VascuVac 인공지능 보조 진공 혈전 절제술 기술
더 보기효율적인 진공 혈전 절제술을 위해 AI 보조 기술을 활용하는 혁신적인 시스템으로, 다음을 위해 설계되었습니다. 신속한 혈전 제거 를 혈관에서 제거합니다, 혈류를 회복합니다, 그리고 절차적 위험 최소화 혈관 중재술에서
-

LaserBLOCK 하지정맥류 레이저 시스템
더 보기An 정맥 내 레이저 치료 세트 정맥류 정맥, 하네스 대상 레이저 에너지로 정맥을 열로 봉합하여 일상 활동으로 빠르게 복귀할 수 있습니다.