Dispositivo di chiusura AngioTEN
A percutaneo sistema di chiusura vascolare per arteria o venoso siti di accesso, consentendo sicuro emostasi dopo cateterismo o procedure interventistiche.
AngioTEN Closure Device by INVAMED is a cyanoacrylate-based closure system designed to seal and stabilize the access site after angiographic procedures. Equipped with a specialized applicator, it ensures precise and user-friendly application of the adhesive over vascular puncture sites, reducing bleeding complications and enhancing patient recovery. By combining rapid polymerization with a biocompatible formula, AngioTEN helps minimize pseudoaneurysm formation and shortens manual compression time—optimizing clinical workflow in catheterization labs.
Cyanoacrylate Adhesive Technology
Employs a fast-curing medical-grade cyanoacrylate that bonds rapidly to tissue edges, helping create a secure and durable seal at the arterial or venous puncture site.
Ergonomic Applicator
Features a slim, intuitive applicator that allows precise dropwise or thin-stripe application, ensuring minimal adhesive wastage and targeted closure even in narrow access points.
Rapid Hemostasis
By instantly sealing the puncture track, AngioTEN reduces the need for prolonged manual compression or adjunct compression devices, potentially improving patient comfort and catheter lab throughput.
Biocompatible & Safe
Formulated to minimize tissue irritation and promote natural healing processes. Ideal for radial or femoral access closure after diagnostic angiography or interventional procedures.
Reduced Risk of Complications
Stabilizing the access site lowers the incidence of hematoma, pseudoaneurysm, or AV fistula formation, supporting safer vascular interventions and quicker discharge protocols.
Controindicazioni
- Heavy calcification, severely diseased artery walls
- Uncontrolled bleeding or coagulopathy beyond standard care measures
- Infection at the puncture site
Specifiche del prodotto
Specifiche | Dettaglio / Valore |
Nome del prodotto | Dispositivo di chiusura AngioTEN |
Uso previsto | Percutaneous vascular closure post-catheterization |
Closure Mechanism | Suture-mediated or collagen plug |
Applicable Access Sites | Femoral artery/vein up to 8F–10F introducer sizes |
Deployment Method | Single-step device insertion and anchor release |
Hemostasis Time | Typically < 1 minute post-deployment |
Sterilità | Sterile, monouso |
Durata di conservazione | ~2–3 years at 15–25 °C |
Matrice di ordinazione e dimensioni
Access Size (F) | Closure Method | Deployment Steps | Codice prodotto |
5–8 | Collagen Plug | Single | ATN-CP-5-8-S |
5–8 | Suture-Mediated | Single | ATN-SM-5-8-S |
8–10 | Collagen Plug | Single | ATN-CP-8-10-S |
8–10 | Suture-Mediated | Single | ATN-SM-8-10-S |
Prodotti correlati
-
Atlas Innesto stent periferico endovascolare
Leggi tuttoA stent periferico coperto offerta di innesti sicuro occlusione di aneurismi o lesioni occlusive in iliaco o femorale segmenti, riducendo il rischio di rottura o riocclusione.
-
Lotus Microcatetere PTCA a lume singolo e doppio (RX)
Leggi tuttoMicrocateteri progettato per coronarica o l'attraversamento periferico della lesione, offrendo configurazioni a uno o due lumi per scambio di fili guida, iniezione di contrastoo accesso subselettivo alla lesione.
-
Sistema di stent coronarico Atlas in acciaio inossidabile
Leggi tuttoA acciaio inox offerta di stent coronarici robusto integrità strutturale e facile per gli interventi coronarici percutanei (PCI) di routine, bilanciando l'efficienza dei costi con prestazioni affidabili.
-
Keeper Rasoio endovascolare
Leggi tuttoA multi loop dispositivo per il recupero delle trappole corpo estraneo o embolo cattura, garantendo sicuro impegno e ritiro dai lumi vascolari.