Cangkok Stent Aorta Atlas

A tertutup sistem stent untuk endovaskular perbaikan aneurisma aorta, mencegah tekanan kantung aneurisma dan memungkinkan patensi lumen yang aman.

Stent Graft Application to Expand Possibilities for Aortic Treatment

• The Atlas Aortic Stent Graft represents a significant leap forward in
aortic lesions.
• Designed with cutting-edge materials and engineering, Atlas Aortic Stent Graft ensures
optimal support and flexibility for aortic interventions.
• Precision-engineered deployment system.

Hybrid Technology to Help Support Improved Patient Outcomes

• With a wide range of sizes, diameters and tapers to customise to the needs of each 
patient.
• Design: The main body stent is high conformability due to varying stent height and is 
kink resistant.
• A multiple tapered configurations that supports the treatment of dissections
The proximal seal has a novel proximal stent design and a mini spring that enhances 
wall apposition.

Every Aspect of the Atlas Aortic Stent-Graft System is Engineered for Performance.

• Two levels of confident fixation. • Lock stent technology works to prevent modular disconnection. • Unique leave-behind sheath to simplify the procedure.

AORTIC STENT GRAFTS ARE INDICATED FOR THE TREATMENT OF AORTIC ANEURYSMS:

  • Less invasive than open surgery
  • Shorter recovery time
  • Lower risk of complications
  • Types of aortic stent grafts

AORTIC STENT GRAFTS ARE INDICATED FOR THE TREATMENT OF AORTIC ANEURYSMS:

  • Large enough to rupture
  • Growing in size
  • Causing symptoms
  • Complications of aortic stent grafts

Spesifikasi Produk Umum

Spesifikasi Detail / Nilai
Nama Produk Cangkok Stent Aorta Atlas
Tujuan Penggunaan Endovascular repair of thoracic or abdominal aortic aneurysms (TAA/AAA), aortic dissections, or traumatic injuries
Desain Balloon-expandable or self-expanding covered stent with ePTFE graft material
Bahan Base scaffold: Nitinol alloy Graft covering: ePTFE / PTFE
Mekanisme Penyebaran Self-expandable: sheath-based release
Sistem Pengiriman Typically 14–24F introducer sheath compatibility, depending on final diameter
Radiopacity Radiopaque markers at proximal and distal ends for precise positioning
Kemandulan Steril (Etilen Oksida)
Sekali Pakai Ya.
Umur simpan ~3–5 years (in sealed packaging at 15–25 °C)
Kompatibilitas MR MR Conditional (verify with labeling)
Indikasi Klinis Infrarenal AAA, TAA, chronic aortic dissection, traumatic aortic tears, side-branch occlusion, etc.
Kontraindikasi Unsuitable neck angles, severe vessel calcification or tortuosity, known nickel allergies (if nitinol)

Cangkok Stent Aorta Atlas

Diameter (mm) Panjang (mm) Sheath Rec. Kode Produk Catatan
20 80 14F ATLS-SG-20x80-SE Smaller diameter, short coverage
20 100 14F ATLS-SG-20x100-SE
20 120 14F ATLS-SG-20x120-SE
22 100 16F ATLS-SG-22x100-SE For moderate aortic diameters
22 140 16F ATLS-SG-22x140-SE Extended coverage
24 120 16F ATLS-SG-24x120-SE Common AAA dimension
24 160 16F ATLS-SG-24x160-SE Extended graft for fusiform aneurysms
26 120 18F ATLS-SG-26x120-SE Larger diameter, moderate length
26 160 18F ATLS-SG-26x160-SE
28 140 20F ATLS-SG-28x140-SE
28 180 20F ATLS-SG-28x180-SE For more extensive aneurysms
30 140 20F ATLS-SG-30x140-SE
30 180 20F ATLS-SG-30x180-SE
32 140 22F ATLS-SG-32x140-SE Large diameter for TAA or big AAA
32 180 22F ATLS-SG-32x180-SE
34 160 22F ATLS-SG-34x160-SE
36 160 22F ATLS-SG-36x160-SE
38 180 24F ATLS-SG-38x180-SE Extremely large aorta
40 200 24F ATLS-SG-40x200-SE Maximum coverage for giant aneurysm or extended segment