Atlas Aortic Stent Graft

A covered stent system for endovascular aortic aneurysm repair, preventing aneurysm sac pressurization and enabling safe lumen patency.

Stent Graft Application to Expand Possibilities for Aortic Treatment

• The Atlas Aortic Stent Graft represents a significant leap forward in
aortic lesions.
• Designed with cutting-edge materials and engineering, Atlas Aortic Stent Graft ensures
optimal support and flexibility for aortic interventions.
• Precision-engineered deployment system.

Hybrid Technology to Help Support Improved Patient Outcomes

• With a wide range of sizes, diameters and tapers to customise to the needs of each 
patient.
• Design: The main body stent is high conformability due to varying stent height and is 
kink resistant.
• A multiple tapered configurations that supports the treatment of dissections
The proximal seal has a novel proximal stent design and a mini spring that enhances 
wall apposition.

Every Aspect of the Atlas Aortic Stent-Graft System is Engineered for Performance.

• Two levels of confident fixation. • Lock stent technology works to prevent modular disconnection. • Unique leave-behind sheath to simplify the procedure.

AORTIC STENT GRAFTS ARE INDICATED FOR THE TREATMENT OF AORTIC ANEURYSMS:

  • Less invasive than open surgery
  • Shorter recovery time
  • Lower risk of complications
  • Types of aortic stent grafts

AORTIC STENT GRAFTS ARE INDICATED FOR THE TREATMENT OF AORTIC ANEURYSMS:

  • Large enough to rupture
  • Growing in size
  • Causing symptoms
  • Complications of aortic stent grafts

General Product Specifications

Specification Detail / Value
Product Name Atlas Aortic Stent Graft
Intended Use Endovascular repair of thoracic or abdominal aortic aneurysms (TAA/AAA), aortic dissections, or traumatic injuries
Design Balloon-expandable or self-expanding covered stent with ePTFE graft material
Material Base scaffold: Nitinol alloy Graft covering: ePTFE / PTFE
Deployment Mechanism Self-expandable: sheath-based release
Delivery System Typically 14–24F introducer sheath compatibility, depending on final diameter
Radiopacity Radiopaque markers at proximal and distal ends for precise positioning
Sterility Sterile (Ethylene Oxide)
Single Use Yes
Shelf Life ~3–5 years (in sealed packaging at 15–25 °C)
MR Compatibility MR Conditional (verify with labeling)
Clinical Indications Infrarenal AAA, TAA, chronic aortic dissection, traumatic aortic tears, side-branch occlusion, etc.
Contraindications Unsuitable neck angles, severe vessel calcification or tortuosity, known nickel allergies (if nitinol)

Atlas Aortic Stent Graft

Diameter (mm) Length (mm) Sheath Rec. Product Code Notes
20 80 14F ATLS-SG-20x80-SE Smaller diameter, short coverage
20 100 14F ATLS-SG-20x100-SE
20 120 14F ATLS-SG-20x120-SE
22 100 16F ATLS-SG-22x100-SE For moderate aortic diameters
22 140 16F ATLS-SG-22x140-SE Extended coverage
24 120 16F ATLS-SG-24x120-SE Common AAA dimension
24 160 16F ATLS-SG-24x160-SE Extended graft for fusiform aneurysms
26 120 18F ATLS-SG-26x120-SE Larger diameter, moderate length
26 160 18F ATLS-SG-26x160-SE
28 140 20F ATLS-SG-28x140-SE
28 180 20F ATLS-SG-28x180-SE For more extensive aneurysms
30 140 20F ATLS-SG-30x140-SE
30 180 20F ATLS-SG-30x180-SE
32 140 22F ATLS-SG-32x140-SE Large diameter for TAA or big AAA
32 180 22F ATLS-SG-32x180-SE
34 160 22F ATLS-SG-34x160-SE
36 160 22F ATLS-SG-36x160-SE
38 180 24F ATLS-SG-38x180-SE Extremely large aorta
40 200 24F ATLS-SG-40x200-SE Maximum coverage for giant aneurysm or extended segment