Stena Multi-Layer Flow Modulator for Peripheral
Flow-diverting stent for שׁוּלִי arteries, redistributing laminar flow away from diseased vessel segments, aiding aneurysm or side-branch preservation.

Stena Multi-Layer Flow Modulator
- Material: Constructed from biocompatible and resilient materials for long-term stability.
- Design: Intricate multilayer design to modulate blood flow and enhance hemodynamic stability.
- Diameter Range: Available in various sizes to cater to different peripheral vascular structures.
Innovate Peripheral Interventions with Advanced Flow Modulation
- Flexibility: High flexibility to conform to the natural anatomy of peripheral vessels.Radial Strength: Provides sufficient support to maintain vessel patency withoutcompromising flexibility.

The Gold Standard in Hemodynamic Stability and Vascular Protection
- Porosity: Designed with optimal porosity to balance flow modulation and preventend-organ ischemia.Compatibility: Compatible with various guide catheters and delivery systemsfor ease of use.
- Its unique multilayer design is a hallmark of innovation, providing unmatched flow modulation and hemodynamic stability.
- This design ensures that blood flow is optimally distributed, reducing the risk of complications and enhancing the overall success of the intervention.
- The device’s construction from biocompatible materials ensures its longevity and reliability, while the range of available sizes guarantees a perfect fit for a variety of peripheral vascular structures.
- The combination of flexibility and radial strength ensures that the device adapts to the patient’s anatomy while maintaining vessel patency and integrity.
- With its optimal porosity and compatibility with various catheters and delivery systems, the Stena Multilayer Flow Modulator stands out as a leader in peripheral vascular care, delivering both innovation and reliability in every procedure.

Endothelialization and integration, as the uncovered device allows endothelial tissue to be generated on the braided structure
מפרט מוצר כללי
מִפרָט | פירוט / ערך |
שם המוצר | Stena Multi-Layer Flow Modulator (Peripheral) |
שימוש מיועד | Endovascular treatment of peripheral aneurysms (e.g., popliteal, iliac) and flow modulation in complex peripheral lesions |
לְעַצֵב | Multi-layer, self-expanding stent with braided nitinol mesh structure |
מנגנון פריסה | Sheath-based retraction for self-expansion; no balloon inflation needed |
חוֹמֶר | Medical-grade Nitinol (Nickel-Titanium) in layered/braided configuration |
מערכת משלוחים | Over-the-wire (OTW), typically 5–8F introducer sheath (depending on stent diameter) |
כוח רדיאלי | Moderate to high, ensuring stable vessel wall contact |
סמנים רדיואקטיביים | Proximal and distal marker bands for fluoroscopic placement |
תאימות MR | MR Conditional (verify local labeling) |
עֲקָרוּת | Sterile (EO) |
לשימוש חד פעמי | כֵּן |
חיי מדף | ~3–5 years if stored at 15–25 °C in sealed packaging |
אינדיקציות קליניות | Peripheral aneurysms (iliac, popliteal), flow diversion in side branches or collateral vessels |
התוויות נגד | Extremely calcified or tortuous peripheral arteries precluding safe deployment; nickel allergy; insufficient landing zone |
Peripheral Flow Modulator
קוטר (מ"מ) | אורך (מ"מ) | נדן Rec. (F) | קוד מוצר | הערות |
5 | 40 | ~5F | STM-P-5x40 | Very small diameter for popliteal or tibial aneurysms |
5 | 60 | ~5F | STM-P-5x60 | |
6 | 40 | ~6F | STM-P-6x40 | Medium diameter, short coverage |
6 | 60 | ~6F | STM-P-6x60 | |
6 | 80 | ~6F | STM-P-6x80 | |
7 | 40 | ~6F | STM-P-7x40 | Slightly larger diameter for moderate vessel |
7 | 80 | ~6F | STM-P-7x80 | |
7 | 100 | ~7F | STM-P-7x100 | Extended coverage for segmental aneurysms |
8 | 60 | ~7F | STM-P-8x60 | Common size for iliac or superficial femoral |
8 | 100 | ~7F | STM-P-8x100 | |
8 | 120 | ~8F | STM-P-8x120 | Longer coverage for multi-lobed aneurysms |
9 | 80 | ~8F | STM-P-9x80 | Larger diameter for proximal popliteal or iliac |
9 | 120 | ~8F | STM-P-9x120 | |
9 | 150 | ~8F | STM-P-9x150 | Max length for extended lesions |
10 | 80 | ~8F | STM-P-10x80 | High diameter for large peripheral arteries |
10 | 120 | ~8F | STM-P-10x120 | |
10 | 150 | ~8F or 9F | STM-P-10x150 | |
12 | 80 | ~9F | STM-P-12x80 | Very large diameter for wide aneurysms |
12 | 120 | ~9F | STM-P-12x120 | |
12 | 150 | ~9F | STM-P-12x150 | Extended coverage for extensive aneurysmal segments |
מוצרים קשורים
-
TemREN Peripheral Atherectomy System
מידע נוסףא סיבובי אוֹ directional atherectomy device specialized for plaque excision in peripheral arteries, augmenting lumen restoration while minimizing barotrauma.
-
מלכודת אנדווסקולרית Keeper
מידע נוסףא רב-לולאה מכשיר לאיסוף מלכודת עבור גוף זר אוֹ תסחיף לכידה, הבטחה מְאוּבטָח אירוסין ו נְסִיגָה מלומן כלי הדם.
-
קטטר בלון PTCA Extender
מידע נוסףא תֶקֶן לחץ גבוה בלון כלילי מיועד ל התרחבות נגעים או עצמאי אנגיופלסטיה, המציע פרופילי ניפוח מדויקים ופרופילי חצייה מופחתים.
-
Dolphin ZEBRA Crossing Support Catheter
מידע נוסףמתמחה ZEBRA-pattern coated support catheter optimizing visibility under fluoroscopy, enabling consistent lesion crossing in מוּרכָּב occlusions.
















































































יצירת קשר ותמיכה
איך נוכל לעזור?
לפני שנתחיל, מה מתאר אותך בצורה הטובה ביותר?
יצירת קשר ותמיכה
אנשי מקצוע בתחום הבריאות
טופס פנייה מקוון
לשאלות כלליות או שאלות הקשורות למוצר, מלאו את הטופס המקוון המהיר שלנו. תקבלו אישור ומספר אסמכתא למעקב.
פניות בנוגע למוצר
תמיכה קלינית ומחקרית
הכשרה וחינוך
תמיכה טכנית
יצירת קשר ותמיכה
מטופל ומטפלים
טופס פנייה מקוון
לשאלות כלליות או שאלות הקשורות למוצר, מלאו את הטופס המקוון המהיר שלנו. תקבלו אישור ומספר אסמכתא למעקב.
שימוש ובטיחות במוצר
הזמנה ותשלום
תמיכה וטיפול לאחר מכן
יצירת קשר ותמיכה
ספקים ומפיצים
טופס פנייה מקוון
לשאלות כלליות או שאלות הקשורות למוצר, מלאו את הטופס המקוון המהיר שלנו. תקבלו אישור ומספר אסמכתא למעקב.
שותפות וחוזה
לוגיסטיקה ומשלוח
תאימות ותיעוד
יצירת קשר ותמיכה
ספקים ומפיצים
טופס פנייה מקוון
לשאלות כלליות או שאלות הקשורות למוצר, מלאו את הטופס המקוון המהיר שלנו. תקבלו אישור ומספר אסמכתא למעקב.
הודעות לעיתונות וחדשות
ראיונות והצהרות
אירועים וכנסים
יצירת קשר ותמיכה
שאלות אחרות / כלליות
טופס פנייה מקוון
לשאלות כלליות או שאלות הקשורות למוצר, מלאו את הטופס המקוון המהיר שלנו. תקבלו אישור ומספר אסמכתא למעקב.
מידע כללי
משוב והצעות
קו תמיכה במטה
- מרכז הסחר העולמי וואן, רחוב פולטון 285. ניו יורק, ניו יורק 10007, ארה"ב
- globalsales@invamed.com
- +1 (347) 535-0630