Système de stent coronaire à élution médicamenteuse ATLAS Cobalt Chromium
A cobalt-chrome pose d'un stent coronaire résistance radiale durable et excellente traçabilité, adapté à complexe ou calcifié des lésions coronaires tout en garantissant un recul minimal.
Le ATLAS Drug Eluting Coronary Stent System is a next-generation cobalt-chromium (CoCr) stent platform coated with a sirolimus formulation (1 µg/mm²) designed to reduce restenosis in patients with coronary artery disease. By combining advanced laser-cutting technology and a clinically proven antiproliferative drug, the ATLAS system delivers durable vessel patency and a high safety profile in both de novo lesions and in-stent restenosis scenarios.
Cobalt-Chromium Alloy (L605) Construction
- Ensures exceptional strength-to-thickness ratio, enabling thinner struts without compromising radial force.
- Exhibits excellent corrosion resistance and biocompatibility for a stable healing environment.
Laser-Cut Stent Design
- Precision machining yields consistent strut geometry, promoting uniform drug distribution and an even healing surface along the vessel wall.
- Enhances stent deliverability, allowing smooth passage through calcified or tortuous coronary segments.
Sirolimus Elution Profile
- 1 µg/mm² of sirolimus is coated onto the stent’s surface, ensuring a sustained, controlled release that minimizes in-stent neointimal growth.
- Controlled drug release aids in rapid endothelialization, lowering the risk of late stent thrombosis.
Radiopaque Pt-Ir Markers
- Platinum-iridium markers at stent edges enable precise visibility under fluoroscopy.
- Facilitates accurate positioning during percutaneous coronary intervention (PCI) procedures.
High-Pressure Capability
interventional cardiologists flexibility to optimize stent expansion based on lesion complexity.
Spécifications | Détail / Valeur |
Nom du produit | Atlas Coronary Stent (Cobalt Chromium) |
Stent Type | Balloon-Expandable Coronary Stent |
Matériau | Cobalt-Chromium Alloy |
Strut Thickness | ~80 µm (typical) |
Conception | Open-cell or hybrid-cell architecture (depending on exact model) |
Nominal Pressure (NP) | 9–10 atm |
Rated Burst Pressure (RBP) | ~14–16 atm |
Stent Delivery System | Rapid-Exchange (RX) or Over-the-Wire (OTW), typically 140 cm shaft length |
Compatibilité des fils-guides | 0.014” |
Stent Surface | Bare-metal or optional drug-eluting polymer (if applicable) |
Indications | Coronary artery lesion scaffolding, single or multivessel disease, potential usage in small/medium/large vessels |
Contre-indications | Lesions unsuited for balloon-expandable stent therapy (e.g., severely calcified, left main trunk, etc.), or as per physician discretion |
Stérilité | Stérile (oxyde d'éthylène) |
Usage unique | Oui |
Durée de conservation | 2–3 years (depending on final packaging and polymer, if any) |
Température de fonctionnement | Recommended 15–25 °C for storage |
Commande détaillée en fonction de la taille et codes produits
Stent Diameter (mm) | Stent Length (mm) | Nominal Pressure (atm) | RBP (atm) | Code produit |
2.00 | 8 | 9 | 14 | ATLS-CC-2.00x08 |
2.00 | 12 | 9 | 14 | ATLS-CC-2.00x12 |
2.00 | 15 | 9 | 14 | ATLS-CC-2.00x15 |
2.00 | 18 | 10 | 16 | ATLS-CC-2.00x18 |
2.00 | 24 | 10 | 16 | ATLS-CC-2.00x24 |
2.00 | 28 | 10 | 16 | ATLS-CC-2.00x28 |
2.00 | 32 | 10 | 16 | ATLS-CC-2.00x32 |
2.00 | 38 | 10 | 16 | ATLS-CC-2.00x38 |
2.25 | 8 | 9 | 14 | ATLS-CC-2.25x08 |
2.25 | 12 | 9 | 14 | ATLS-CC-2.25x12 |
2.25 | 15 | 9 | 14 | ATLS-CC-2.25x15 |
2.25 | 18 | 10 | 16 | ATLS-CC-2.25x18 |
2.25 | 24 | 10 | 16 | ATLS-CC-2.25x24 |
2.25 | 28 | 10 | 16 | ATLS-CC-2.25x28 |
2.25 | 32 | 10 | 16 | ATLS-CC-2.25x32 |
2.25 | 38 | 10 | 16 | ATLS-CC-2.25x38 |
2.50 | 8 | 9 | 14 | ATLS-CC-2.50x08 |
2.50 | 12 | 9 | 14 | ATLS-CC-2.50x12 |
2.50 | 15 | 9 | 14 | ATLS-CC-2.50x15 |
2.50 | 18 | 10 | 16 | ATLS-CC-2.50x18 |
2.50 | 24 | 10 | 16 | ATLS-CC-2.50x24 |
2.50 | 28 | 10 | 16 | ATLS-CC-2.50x28 |
2.50 | 32 | 10 | 16 | ATLS-CC-2.50x32 |
2.50 | 38 | 10 | 16 | ATLS-CC-2.50x38 |
2.75 | 8 | 9 | 14 | ATLS-CC-2.75x08 |
2.75 | 12 | 9 | 14 | ATLS-CC-2.75x12 |
2.75 | 15 | 9 | 14 | ATLS-CC-2.75x15 |
2.75 | 18 | 10 | 16 | ATLS-CC-2.75x18 |
2.75 | 24 | 10 | 16 | ATLS-CC-2.75x24 |
2.75 | 28 | 10 | 16 | ATLS-CC-2.75x28 |
2.75 | 32 | 10 | 16 | ATLS-CC-2.75x32 |
2.75 | 38 | 10 | 16 | ATLS-CC-2.75x38 |
3.00 | 8 | 9 | 14 | ATLS-CC-3.00x08 |
3.00 | 12 | 9 | 14 | ATLS-CC-3.00x12 |
3.00 | 15 | 9 | 14 | ATLS-CC-3.00x15 |
3.00 | 18 | 10 | 16 | ATLS-CC-3.00x18 |
3.00 | 24 | 10 | 16 | ATLS-CC-3.00x24 |
3.00 | 28 | 10 | 16 | ATLS-CC-3.00x28 |
3.00 | 32 | 10 | 16 | ATLS-CC-3.00x32 |
3.00 | 38 | 10 | 16 | ATLS-CC-3.00x38 |
3.25 | 12 | 9 | 14 | ATLS-CC-3.25x12 |
3.25 | 15 | 9 | 14 | ATLS-CC-3.25x15 |
3.25 | 18 | 10 | 16 | ATLS-CC-3.25x18 |
3.25 | 24 | 10 | 16 | ATLS-CC-3.25x24 |
3.25 | 28 | 10 | 16 | ATLS-CC-3.25x28 |
3.25 | 32 | 10 | 16 | ATLS-CC-3.25x32 |
3.25 | 38 | 10 | 16 | ATLS-CC-3.25x38 |
3.50 | 8 | 9 | 14 | ATLS-CC-3.50x08 |
3.50 | 12 | 9 | 14 | ATLS-CC-3.50x12 |
3.50 | 15 | 9 | 14 | ATLS-CC-3.50x15 |
3.50 | 18 | 10 | 16 | ATLS-CC-3.50x18 |
3.50 | 24 | 10 | 16 | ATLS-CC-3.50x24 |
3.50 | 28 | 10 | 16 | ATLS-CC-3.50x28 |
3.50 | 32 | 10 | 16 | ATLS-CC-3.50x32 |
3.50 | 38 | 10 | 16 | ATLS-CC-3.50x38 |
4.00 | 8 | 9 | 14 | ATLS-CC-4.00x08 |
4.00 | 12 | 9 | 14 | ATLS-CC-4.00x12 |
4.00 | 15 | 9 | 14 | ATLS-CC-4.00x15 |
4.00 | 18 | 10 | 16 | ATLS-CC-4.00x18 |
4.00 | 24 | 10 | 16 | ATLS-CC-4.00x24 |
4.00 | 28 | 10 | 16 | ATLS-CC-4.00x28 |
4.00 | 32 | 10 | 16 | ATLS-CC-4.00x32 |
4.00 | 38 | 10 | 16 | ATLS-CC-4.00x38 |
Produits similaires
-
Video Laryngoscope
Continuer la lectureDispositif médical de haute précision composé de matériaux durables et biocompatibles, conçu pour permettre une meilleure visualisation des voies aériennes pendant l'intubation, améliorant ainsi la sécurité et l'efficacité des procédures de gestion des voies aériennes.
-
TemREN Système d'athérectomie périphérique
Continuer la lectureA rotationnel ou directionnel dispositif d'athérectomie spécialisé pour excision de la plaque dans les artères périphériques, augmentant lumen tout en minimisant le barotraumatisme.
-
Cathéter à ballonnet PTCA Extender
Continuer la lectureA standard haute pression ballon coronaire conçu pour prédilatation des lésions ou autonome angioplastieLes profils de gonflage sont précis et les profils de croisement sont réduits.
-
SteerCATH Cathéter orientable
Continuer la lectureA orientable soutenir le cathéter avec déformable de la pointe, conçue pour des applications complexes ou vaisseau de branchement dans les interventions coronaires et périphériques. Améliore la réussite des croisements dans les anatomies difficiles.