Dispositif de fermeture AngioTEN
A percutanée système de fermeture vasculaire pour artériel ou veineux sites d'accès, ce qui permet sécurisé l'hémostase après un cathétérisme ou des procédures interventionnelles.
AngioTEN Closure Device by INVAMED is a cyanoacrylate-based closure system designed to seal and stabilize the access site after angiographic procedures. Equipped with a specialized applicator, it ensures precise and user-friendly application of the adhesive over vascular puncture sites, reducing bleeding complications and enhancing patient recovery. By combining rapid polymerization with a biocompatible formula, AngioTEN helps minimize pseudoaneurysm formation and shortens manual compression time—optimizing clinical workflow in catheterization labs.
Cyanoacrylate Adhesive Technology
Employs a fast-curing medical-grade cyanoacrylate that bonds rapidly to tissue edges, helping create a secure and durable seal at the arterial or venous puncture site.
Ergonomic Applicator
Features a slim, intuitive applicator that allows precise dropwise or thin-stripe application, ensuring minimal adhesive wastage and targeted closure even in narrow access points.
Rapid Hemostasis
By instantly sealing the puncture track, AngioTEN reduces the need for prolonged manual compression or adjunct compression devices, potentially improving patient comfort and catheter lab throughput.
Biocompatible & Safe
Formulated to minimize tissue irritation and promote natural healing processes. Ideal for radial or femoral access closure after diagnostic angiography or interventional procedures.
Reduced Risk of Complications
Stabilizing the access site lowers the incidence of hematoma, pseudoaneurysm, or AV fistula formation, supporting safer vascular interventions and quicker discharge protocols.
Contre-indications
- Heavy calcification, severely diseased artery walls
- Uncontrolled bleeding or coagulopathy beyond standard care measures
- Infection at the puncture site
Spécifications des produits
Spécifications | Détail / Valeur |
Nom du produit | Dispositif de fermeture AngioTEN |
Utilisation prévue | Percutaneous vascular closure post-catheterization |
Closure Mechanism | Suture-mediated or collagen plug |
Applicable Access Sites | Femoral artery/vein up to 8F–10F introducer sizes |
Deployment Method | Single-step device insertion and anchor release |
Hemostasis Time | Typically < 1 minute post-deployment |
Stérilité | Stérile, à usage unique |
Durée de conservation | ~2–3 years at 15–25 °C |
Commande et matrice des tailles
Access Size (F) | Closure Method | Deployment Steps | Code produit |
5–8 | Collagen Plug | Single | ATN-CP-5-8-S |
5–8 | Suture-Mediated | Single | ATN-SM-5-8-S |
8–10 | Collagen Plug | Single | ATN-CP-8-10-S |
8–10 | Suture-Mediated | Single | ATN-SM-8-10-S |
Produits apparentés
-
ATLAS Système de stent coronaire à élution médicamenteuse Cobalt Chrome
Lire la suiteA cobalt-chrome pose d'un stent coronaire résistance radiale durable et excellente traçabilité, adapté à complexe ou calcifié des lésions coronaires tout en garantissant un recul minimal.
-
SteerCATH Cathéter orientable
Lire la suiteA orientable soutenir le cathéter avec déformable de la pointe, conçue pour des applications complexes ou vaisseau de branchement dans les interventions coronaires et périphériques. Améliore la réussite des croisements dans les anatomies difficiles.
-
Atlas Peripheral Stent System
Lire la suiteA robust peripheral stent platform designed for fémoral, iliaqueou popliteal lesions, ensuring adequate support radial et low restenosis rates in PAD interventions.
-
AngioCATH Cathéters de guidage
Lire la suiteCathéters de guidage haute performance avec couple optimal réponse et pointe précise formes pour coronaire ou périphérique garantissant la stabilité du dispositif et la clarté de l'imagerie.