Dispositivo de cierre AngioTEN
A percutánea sistema de cierre vascular para arterial o venoso de acceso, lo que permite seguro hemostasia tras cateterismo o procedimientos intervencionistas.
AngioTEN Closure Device by INVAMED is a cyanoacrylate-based closure system designed to seal and stabilize the access site after angiographic procedures. Equipped with a specialized applicator, it ensures precise and user-friendly application of the adhesive over vascular puncture sites, reducing bleeding complications and enhancing patient recovery. By combining rapid polymerization with a biocompatible formula, AngioTEN helps minimize pseudoaneurysm formation and shortens manual compression time—optimizing clinical workflow in catheterization labs.
Cyanoacrylate Adhesive Technology
Employs a fast-curing medical-grade cyanoacrylate that bonds rapidly to tissue edges, helping create a secure and durable seal at the arterial or venous puncture site.
Ergonomic Applicator
Features a slim, intuitive applicator that allows precise dropwise or thin-stripe application, ensuring minimal adhesive wastage and targeted closure even in narrow access points.
Rapid Hemostasis
By instantly sealing the puncture track, AngioTEN reduces the need for prolonged manual compression or adjunct compression devices, potentially improving patient comfort and catheter lab throughput.
Biocompatible & Safe
Formulated to minimize tissue irritation and promote natural healing processes. Ideal for radial or femoral access closure after diagnostic angiography or interventional procedures.
Reduced Risk of Complications
Stabilizing the access site lowers the incidence of hematoma, pseudoaneurysm, or AV fistula formation, supporting safer vascular interventions and quicker discharge protocols.
Contraindicaciones
- Heavy calcification, severely diseased artery walls
- Uncontrolled bleeding or coagulopathy beyond standard care measures
- Infection at the puncture site
Especificaciones del producto
Especificación | Detalle / Valor |
Nombre del producto | Dispositivo de cierre AngioTEN |
Uso previsto | Percutaneous vascular closure post-catheterization |
Closure Mechanism | Suture-mediated or collagen plug |
Applicable Access Sites | Femoral artery/vein up to 8F–10F introducer sizes |
Deployment Method | Single-step device insertion and anchor release |
Hemostasis Time | Typically < 1 minute post-deployment |
Esterilidad | Estéril, un solo uso |
Vida útil | ~2–3 years at 15–25 °C |
Matriz de pedidos y tamaños
Access Size (F) | Closure Method | Deployment Steps | Código del producto |
5–8 | Collagen Plug | Single | ATN-CP-5-8-S |
5–8 | Suture-Mediated | Single | ATN-SM-5-8-S |
8–10 | Collagen Plug | Single | ATN-CP-8-10-S |
8–10 | Suture-Mediated | Single | ATN-SM-8-10-S |
Productos relacionados
-
Rotablator TemREN
Leer másA rotacional sistema de trombectomía o aterectomía dotado de alta velocidad rebabas para moler o eliminar la placa calcificada, garantizando una mejor expansión del lumen para la colocación del stent.
-
Video Laryngoscope
Leer másA high-precision medical device made of durable, biocompatible materials, designed to provide enhanced visualization of the airway during intubation, improving safety and efficiency in airway management procedures.
-
InWIRE 0.014” & 0.018” CTO Guidewire
Leer másA range of high-performance guidewires offering durable nitinol or stainless cores, hydrophilic coatings, and multiple tip shapes for crossing calcificado o complejo coronary & peripheral lesions.
-
Lotus Microcatéter PTCA de un solo lumen y doble lumen (RX)
Leer másMicrocatéteres diseñado para coronaria o lesiones periféricas, con configuraciones de uno o dos lúmenes para intercambio de guías, inyección de contrasteo acceso subselectivo a la lesión.