MultiBEAM Inferior Vena Cava (IVC) Filter
A convertible or retrievable IVC filter preventing pulmonary emboli by intercepting clots traveling through the inferior vena cava, ensuring safety in high-risk patients.
The MultiBEAM Inferior Vena Cava (IVC) Filter, offered by Invamed—a global medical device manufacturer—is designed to capture and retain thromboembolic fragments traveling within the venous system, thereby reducing the risk of pulmonary embolism (PE). Featuring a self-expanding metallic framework, MultiBEAM provides robust fixation in the IVC while facilitating high patency and stable clot containment.
Self-Expanding Nitinol Struts
Engineered from a biocompatible alloy for secure anchoring, even under shifting venous pressures.
Multi-Spoke or “Beam” Design
Creates multiple capture zones that efficiently trap emboli without significantly restricting blood flow, sustaining venous return.
Retrievable/Optional Permanent
Certain models allow retrieval within a designated window, while others function as permanent PE prophylaxis solutions—offering clinicians flexibility in management.
Reduced Migration & Tilt
Precisely balanced struts help prevent filter migration or tilting, enhancing performance consistency over time.
Wide Application Scope
Indicated for patients at elevated PE risk due to venous thromboembolism (VTE), inadequate response to anticoagulants, or temporary contraindications to anticoagulation therapy.
Kontraindikationen
Excessively narrow or tortuous IVC diameter preventing secure seating, active infection at insertion site, or patient-specific anatomical constraints.
Produktspezifikationen
Spezifikation | Detail / Wert |
Produktname | MultiBEAM Inferior Vena Cava (IVC) Filter |
Verwendungszweck | Prevention of pulmonary embolism by capturing clots traveling from lower extremity or pelvic veins |
Filter Design | Self-expanding metal struts (Nitinol or stainless steel) arranged in a multi-beam pattern |
Mechanismus für den Einsatz | Over-the-wire or sheath-based insertion, typically via femoral or jugular access |
Retrieval Option | Some models are optionally retrievable within a specific timeframe (check product line) |
Filter Diameter Range | Suited for IVC diameters ~20–30 mm (varies by product code) |
Röntgendichte Markierungen | Distal apex or anchor tips for fluoroscopic identification |
MR-Kompatibilität | MR Bedingt (Beschriftung prüfen) |
Sterilität | Steril, Einmalgebrauch |
Haltbarkeitsdauer | ~3-5 Jahre bei Lagerung bei 15-25 °C in verschlossener Verpackung |
Klinische Indikationen | Patients at risk of pulmonary embolism (PE), especially with contraindications to anticoagulation |
Kontraindikationen | Severe IVC anatomical anomalies, high-level occlusion, known allergy to device materials |
Bestell- & Größenmatrix
IVC Diameter Suitability (mm) | Filter Apex to Anchor (mm) | Retrieval Window (days) | Produkt-Code | Anmerkungen |
< 24 | 26 | 30 | MBI-<24-40-30 | Smaller IVC or narrow diameters |
< 24 | 26 | 90 | MBI-<24-50-90 | Extended retrieval time |
20–28 | 33 | 30 | MBI-20-28-50-30 | Common range for standard IVC diameters |
20–28 | 33 | 90 | MBI-20-28-60-90 | Longer apex distance + extended retrieval |
28–30 | 33 | 30 | MBI-28-30-60-30 | For larger IVC diameter, shorter retrieval |
28–30 | 33 | 90 | MBI-28-30-70-90 | Largest apex span + extended retrieval |
Ähnliche Produkte
-
VeinOFF Mittel zur Krampfaderbehandlung
WeiterlesenEine spezialisierte Sklerosierungsmittel oder Klebstoff Formel, die darauf abzielt nicht thermisch Beseitigung von Krampfadern, die eine minimale Anästhesie und eine kurze Behandlungszeit erfordert.
-
Mantis CURVE Over-the-Wire (OTW) Rotationspharmakomechanisches Thrombektomiesystem
WeiterlesenEine drahtlos (OTW) Gerätezusammenführung Rotation Unterbrechung mit pharmakologisch Lyse, wodurch große Thromben wirksam beseitigt und gleichzeitig gesunde Gefäßwände geschützt werden.
-
Dovi Thrombus Ultra Aspiration Catheter
WeiterlesenA high-vacuum aspiration catheter for acute oder subacute thrombus removal in arterial or venous beds, ensuring rapid revascularization with minimal fragmentation risk.
-
ThermoBLOCK Krampfader-Radiofrequenzablationssystem
WeiterlesenA Hochfrequenz Ablationsplattform für inkompetent oberflächliche Venen, die thermisch Verschluss von Saphena- oder Perforansvenen zur Entlastung Krampfadern Symptome.