Mantis CURVE Over-the-Wire (OTW) Rotationspharmakomechanisches Thrombektomiesystem
Eine drahtlos (OTW) Gerätezusammenführung Rotation Unterbrechung mit pharmakologisch Lyse, wodurch große Thromben wirksam beseitigt und gleichzeitig gesunde Gefäßwände geschützt werden.
Rotational Pharmacomechanical Thrombectomy
- Venturi Effect Mechanism: As the active tip spins within the vessel lumen, a hydrodynamic vortex forms, enabling targeted fragmentation and aspiration of the thrombus.
- Drug Infusion Port: Concurrent infusion of anti-thrombolytic agents ensures cohesive mixing with the thrombus, expediting clot dissolution and clearance.
Active Tip with Coil & Sinusoidal Wave
- Coil Design: The sinusoidal wave geometry, visible from the distal tip to proximal region, efficiently engages and fragments clot.
- Preventing Distal Embolism: The rotational vortex action, combined with controlled drug release, helps retain clot particles in proximity for prompt removal, reducing the risk of distal migration.
Over-the-Wire (OTW) Catheter System
- 0.035” Guidewire Compatibility: Simplifies wire management in complex anatomies (including tortuous or large-diameter vessels).
- Catheter Lengths: With 90 cm and 110 cm functional lengths, and 120 cm or 135 cm profiles, the system accommodates an array of procedural approaches.
Multiple Catheter Profiles & Radiopacity
- 5.0F to 8.0F: Offers suitable sizing for broad vessel diameters in the peripheral venous circulation, pulmonary artery, or IVC.
- Radiopaque: The braided shaft is visible under fluoroscopy from distal tip to proximal segment, aiding real-time device positioning.
PTFE-Innenauskleidung
- Low-Friction Catheter Lumen: Streamlines guidewire passage and drug infusion, helping avoid clot or tissue adherence to the catheter walls.
- Reduced Shear Stress: Minimizes friction on vessel endothelium, supporting safer navigation in high-stakes procedures.
Produktspezifikationen
| Spezifikation | Detail / Wert |
| Produktname | Mantis CURVE OTW Rotational Pharmacomechanical Thrombectomy System |
| Verwendungszweck | Combined mechanical disruption + lytic infusion for acute/subacute thrombosis in peripheral or venous systems |
| Katheter-Design | Over-the-wire shaft with curved rotational tip for enhanced clot contact, integrated infusion port |
| Rotational Speed Range | ~40k–80k rpm (verify final) |
| Infusion Mechanism | Side port or multi-hole segment for tPA or lytic agent delivery |
| Außendurchmesser (F) | ~5–7F, depending on model |
| Arbeitslänge | ~80–120 cm (varies by product code) |
| Kompatibilität der Führungsdrähte | Typically 0.035” (OTW approach) |
| Sterilität | Steril, Einmalgebrauch |
| Haltbarkeitsdauer | ~2-3 Jahre bei 15-25 °C in verschlossener Verpackung |
| Klinische Indikationen | Deep venous thrombosis (DVT), acute peripheral arterial occlusions, possibly for pulmonary thrombosis (per label) |
| Kontraindikationen | Extremely tortuous vessels, heavy calcification, or known device material allergies |
Bestell- & Größenmatrix
| Außendurchmesser (F) | Arbeitslänge (cm) | Curve Tip Configuration | Produkt-Code | Anmerkungen |
| 5F | 80 | Moderate Curve | MNT-CV-5F-80-MC | Smaller lumen, shorter approach |
| 5F | 100 | Deep Curve | MNT-CV-5F-100-DC | Extended shaft, deeper curve for better clot contact |
| 6F | 80 | Moderate Curve | MNT-CV-6F-80-MC | Common size for peripheral thrombectomy |
| 6F | 120 | Deep Curve | MNT-CV-6F-120-DC | Extended length with advanced curve tip |
| 7F | 100 | Moderate Curve | MNT-CV-7F-100-MC | Larger lumen for heavier clot burden |
| 7F | 120 | Deep Curve | MNT-CV-7F-120-DC | Max length, enhanced curve for extensive occlusions |
Ähnliche Produkte
-

VenoNeedle® RF-Ablationssystem für kleine Venen
WeiterlesenA Stromsparend thermisches System mit dem Ziel BesenreiserTeleangiektasien oder kleine retikuläre Varizen mit genau Koagulation, wodurch große Einschnitte oder längere Ausfallzeiten vermieden werden.
-

ThermoBLOCK Krampfader-Radiofrequenzablationssystem
WeiterlesenA radiofrequency ablation platform for incompetent superficial veins, offering thermal closure of saphenous or perforating veins to relieve varicose symptoms.
-

Venablock ™ Krampfadern Behandlung Venenverschlusssystem
WeiterlesenVenablock ™ Krampfadern Behandlung Venenverschlusssystem; A Cyanacrylat-Basis Venenverschlusssystem für oberflächlich Veneninsuffizienz, Entbindung nicht thermisch Okklusion mit minimaler Lokalanästhesie und schnell Erholung nach dem Eingriff.
-

ICT Interne Kompressionstherapie
WeiterlesenICT-Ventilleckdichtungs-Rekonstruktionssystem
Die ICT ist eine interne Kompressionstherapie für funktionsgestörte Venenklappen. Das Verfahren wird auch als perkutane Valvuloplastie bezeichnet.
