Atlas Endovaskulärer Peripherer Stentgraft
A abgedeckter peripherer Stent Transplantatangebot sicher Verschluss von Aneurysmen oder verschließenden Läsionen in Iliakal oder Oberschenkel Segmente, wodurch das Risiko einer Ruptur oder eines erneuten Verschlusses verringert wird.

Reinforced Stability, Unparalleled Durability
Elevate Vascular Repair with the Power of Carbon:
• Durability: The carbon coating adds an extra layer of strength and resilience. • Biocompatibility: Designed to minimize irritation and promote faster recovery. • Radiopacity: Enhanced visibility under imaging for precise placement.


Precision, Protection, Performance:
SIGNIFICANT ADVANCEMENT IN ENDOVASCULAR REPAIR TECHNOLOGY
ENHANCED WITH A ROBUST CARBON COATING OPTIMIZED FOR BOTH FLEXIBILITY AND CONFORMABILITY
Self-Expanding Nitinol Framework
- Shape-Memory Alloy: Nitinol’s superelastic properties enable consistent radial force to maintain stent apposition, conforming effectively to vessel anatomies.
- Tantalum Markings: Both stent ends include tantalum markers, providing high radiopacity for precise positioning under fluoroscopy.
Microporous ePTFE Graft Material
- Sealing Function: The ePTFE covering excludes blood flow from the aneurysmal or diseased arterial wall, helping reduce the risk of endoleaks.
- Biocompatible & Low Profile: The microporous structure supports healing while limiting inflammatory responses.
Single-Stent Design
- Straightforward Implantation: Simplifies device selection and deployment, particularly beneficial in peripheral lesions requiring a single stent graft solution.
- Enhanced Device Integrity: Minimizes potential junctional leak points or component separations sometimes encountered in multi-piece stent systems.
Carbon Surface Coating
- Thromboresistant: The carbon coating on the stent struts aims to reduce platelet adhesion, promoting stable device integration and lower incidence of thrombosis.
- Smooth Flow Lumen: Enhances hemodynamic compatibility and may further limit intimal hyperplasia.
Wide Diameter and Length Range
- Stent Graft Size: 5.0 to 10.0 mm diameters address multiple peripheral vessel diameters.
- Nominal Stent Graft Length: Ranging from 18 to 58 mm in designated sizes (18, 22, 28, 38, 58 or 18, 23, 27, 37, 57)—covering a broad spectrum of lesion lengths.
Allgemeine Produktspezifikationen
Spezifikation | Detail / Wert |
Produktname | Atlas Endovascular Stent Graft |
Verwendungszweck | Endovascular repair of peripheral aneurysms, arterial occlusive disease, or traumatic injuries (iliac, femoral, popliteal) |
Graft Material | ePTFE covering over metal scaffold |
Scaffold Material | Nitinol (self-expanding depending on design) |
Deployment Method | Over-the-wire with introducer sheath (commonly 14F–18F, depending on stent diameter) |
Radiale Kraft | Medium-High, ensuring stable vessel wall apposition |
Delivery Shaft Length | Typically 80–120 cm (verify exact product specs) |
Röntgendichte Markierungen | Proximal and distal markers to guide accurate placement |
Sterilität | Steril (Ethylenoxid) |
Einmaliger Gebrauch | Ja |
Haltbarkeitsdauer | ~3-5 Jahre bei Lagerung bei 15-25 °C in verschlossener Verpackung |
MR-Kompatibilität | MR Bedingt (Beschriftung prüfen) |
Klinische Indikationen | Peripheral artery aneurysms (iliac, femoral), endoluminal bridging for traumatic or pseudoaneurysms, possible bypass for occlusive lesions |
Kontraindikationen | Extremely calcified or tortuous vessels preventing safe device passage, known nickel or metal allergies |
Atlas Endovascular Stent Graft
Durchmesser (mm) | Länge (mm) | Ummantelung Rec. (F) | Produkt-Code | Anmerkungen |
6 | 40 | ~14F | AESG-6x40 | Small diameter for distal external iliac or femoral |
6 | 60 | ~14F | AESG-6x60 | |
6 | 80 | ~14F | AESG-6x80 | |
7 | 40 | ~14F | AESG-7x40 | Slightly larger for moderate-sized arteries |
7 | 80 | ~14F | AESG-7x80 | |
7 | 100 | ~14F | AESG-7x100 | |
8 | 60 | ~14–16F | AESG-8x60 | Common size for iliac region |
8 | 80 | ~14–16F | AESG-8x80 | |
8 | 120 | ~16F | AESG-8x120 | Longer coverage for extensive lesion |
9 | 60 | ~16F | AESG-9x60 | For large external iliac or superficial femoral |
9 | 100 | ~16F | AESG-9x100 | |
9 | 150 | ~16F | AESG-9x150 | Extended length for multi-segment disease |
10 | 60 | ~16–18F | AESG-10x60 | Larger diameter for bigger femoral or proximal arteries |
10 | 120 | ~18F | AESG-10x120 | |
10 | 150 | ~18F | AESG-10x150 | |
12 | 80 | ~18F | AESG-12x80 | Very large diameter bridging aneurysms |
12 | 100 | ~18F | AESG-12x100 | |
12 | 150 | ~18F | AESG-12x150 | Maximum coverage for extensive peripheral disease |
12 | 200 | ~18F | AESG-12x200 | Very long stent graft for special cases |
Ähnliche Produkte
-
Dolphin PRO Niedrigprofil-Kreuzungsunterstützungskatheter
WeiterlesenA flaches Profil Kreuzungskatheter mit verbesserter Aufschiebbarkeit und Verfolgbarkeit, konzipiert für dicht oder schwer verkalkt Läsionen in den Herzkranzgefäßen oder in den peripheren Arterien.
-
Extender PTCA-Ballonkatheter
WeiterlesenA Standard Hochdruck Koronarballon konzipiert für Läsionsvorbereitung oder allein stehend Angioplastieund bietet präzise Inflationsprofile und reduzierte Kreuzungsprofile.
-
Viper™ Valved Infusion Catheters
WeiterlesenDie Viper™ Valved Infusion Catheter ist eine single-lumen, valved-tip delivery system that offers the flexibility to infuse anti-thrombus agents, radiopaque contrast, or other physician-specified pharmacologic solutions with oder without a guidewire in place.
-
TemREN System für periphere Atherektomie
WeiterlesenA Rotation oder Richtungsweisend Atherektomiegerät speziell für Plaque-Entfernung in den peripheren Arterien, was zu einer Verstärkung Lumen Wiederherstellung bei gleichzeitiger Minimierung des Barotraumas.
















































































Kontakt & Unterstützung
Wie können wir helfen?
Bevor wir anfangen, was beschreibt Sie am besten?
Kontakt & Unterstützung
Fachkräfte im Gesundheitswesen
Online-Anfrageformular
Für allgemeine oder produktbezogene Fragen füllen Sie bitte unser Online-Formular aus. Sie erhalten eine Bestätigung und eine Referenznummer für die Sendungsverfolgung.
Produkt-Anfragen
Unterstützung für Klinik und Forschung
Ausbildung und Schulung
Technische Unterstützung
Kontakt & Unterstützung
Patienten und Betreuer
Online-Anfrageformular
Für allgemeine oder produktbezogene Fragen füllen Sie bitte unser Online-Formular aus. Sie erhalten eine Bestätigung und eine Referenznummer für die Sendungsverfolgung.
Produktverwendung und Sicherheit
Bestellung & Bezahlung
Betreuung & Nachsorge
Kontakt & Unterstützung
Lieferanten und Vertriebshändler
Online-Anfrageformular
Für allgemeine oder produktbezogene Fragen füllen Sie bitte unser Online-Formular aus. Sie erhalten eine Bestätigung und eine Referenznummer für die Sendungsverfolgung.
Partnerschaft & Vertrag
Logistik und Versand
Einhaltung der Vorschriften und Dokumentation
Kontakt & Unterstützung
Lieferanten und Vertriebshändler
Online-Anfrageformular
Für allgemeine oder produktbezogene Fragen füllen Sie bitte unser Online-Formular aus. Sie erhalten eine Bestätigung und eine Referenznummer für die Sendungsverfolgung.
Pressemitteilungen & Nachrichten
Interviews und Stellungnahmen
Veranstaltungen & Konferenzen
Kontakt & Unterstützung
Sonstiges / Allgemeine Anfragen
Online-Anfrageformular
Für allgemeine oder produktbezogene Fragen füllen Sie bitte unser Online-Formular aus. Sie erhalten eine Bestätigung und eine Referenznummer für die Sendungsverfolgung.
Allgemeine Informationen
Feedback und Vorschläge
HeadQuarter-Supportleitung
- One World Trade Center, 285 Fulton Street. New York, NY 10007, USA
- globalsales@invamed.com
- +1 (347) 535-0630