AngioTEN Verschlußvorrichtung
A perkutan Gefäßverschlusssystem für arterielle oder venös Zugang zu Websites, wodurch sicher Blutstillung nach Katheterisierung oder interventionellen Eingriffen.
AngioTEN Closure Device by INVAMED is a cyanoacrylate-based closure system designed to seal and stabilize the access site after angiographic procedures. Equipped with a specialized applicator, it ensures precise and user-friendly application of the adhesive over vascular puncture sites, reducing bleeding complications and enhancing patient recovery. By combining rapid polymerization with a biocompatible formula, AngioTEN helps minimize pseudoaneurysm formation and shortens manual compression time—optimizing clinical workflow in catheterization labs.
Cyanoacrylate Adhesive Technology
Employs a fast-curing medical-grade cyanoacrylate that bonds rapidly to tissue edges, helping create a secure and durable seal at the arterial or venous puncture site.
Ergonomic Applicator
Features a slim, intuitive applicator that allows precise dropwise or thin-stripe application, ensuring minimal adhesive wastage and targeted closure even in narrow access points.
Rapid Hemostasis
By instantly sealing the puncture track, AngioTEN reduces the need for prolonged manual compression or adjunct compression devices, potentially improving patient comfort and catheter lab throughput.
Biocompatible & Safe
Formulated to minimize tissue irritation and promote natural healing processes. Ideal for radial or femoral access closure after diagnostic angiography or interventional procedures.
Reduced Risk of Complications
Stabilizing the access site lowers the incidence of hematoma, pseudoaneurysm, or AV fistula formation, supporting safer vascular interventions and quicker discharge protocols.
Kontraindikationen
- Heavy calcification, severely diseased artery walls
- Uncontrolled bleeding or coagulopathy beyond standard care measures
- Infection at the puncture site
Produktspezifikationen
Spezifikation | Detail / Wert |
Produktname | AngioTEN Verschlußvorrichtung |
Verwendungszweck | Percutaneous vascular closure post-catheterization |
Closure Mechanism | Suture-mediated or collagen plug |
Applicable Access Sites | Femoral artery/vein up to 8F–10F introducer sizes |
Deployment Method | Single-step device insertion and anchor release |
Hemostasis Time | Typically < 1 minute post-deployment |
Sterilität | Steril, Einmalgebrauch |
Haltbarkeitsdauer | ~2–3 years at 15–25 °C |
Bestell- & Größenmatrix
Access Size (F) | Closure Method | Deployment Steps | Produkt-Code |
5–8 | Collagen Plug | Single | ATN-CP-5-8-S |
5–8 | Suture-Mediated | Single | ATN-SM-5-8-S |
8–10 | Collagen Plug | Single | ATN-CP-8-10-S |
8–10 | Suture-Mediated | Single | ATN-SM-8-10-S |
Ähnliche Produkte
-
AngioCATH-Führungskatheter
WeiterlesenHochleistungs-Führungskatheter mit optimales Drehmoment Reaktion und präzise Spitze Formen für Koronar oder Peripheriegeräte Interventionen, die eine stabile Geräteversorgung und eine klare Bildgebung gewährleisten.
-
Lotus Einlumiger und zweilumiger (RX) PTCA-Mikrokatheter
WeiterlesenMikrokatheter konzipiert für Koronar oder periphere Läsion durchqueren, mit ein- oder zweilumigen Konfigurationen für Austausch von Führungsdrähten, Kontrastmittelinjektionoder subselektiver Läsionszugang.
-
Stena Mehrschichtiger Durchflussmodulator für Peripheriegeräte
WeiterlesenStrömungsumlenkung Stent für Peripheriegeräte Arterien, Umverteilung von laminar Der Fluss wird von den erkrankten Gefäßsegmenten abgeleitet, was den Erhalt von Aneurysmen oder Seitenästen unterstützt.
-
Atlas Peripheres Stent-System
WeiterlesenEine robuste peripherer Stent Plattform entwickelt für Oberschenkel, Iliakal, oder popliteal Läsionen, die sicherstellen angemessen radiale Abstützung und niedrig Restenoseraten bei PAD-Eingriffen.