Atlas Koronarstentsystem aus Edelstahl
A rostfreier Stahl Angebot an Koronarstents robust strukturelle Integrität und einfach für routinemäßige perkutane Koronarinterventionen (PCI), die ein Gleichgewicht zwischen Kosteneffizienz und zuverlässiger Leistung herstellen.
Die ATLAS Drug Eluting Coronary Stent System SS is a stainless steel (SS) stent platform coated with a sirolimus formulation (1 µg/mm²), designed to prevent restenosis and support durable revascularization in patients with coronary artery disease. By delivering a targeted antiproliferative effect at the lesion site, it is indicated for both de novo coronary lesions and in-stent restenosis (ISR) management, thereby extending its clinical versatility in the percutaneous coronary intervention (PCI) setting.
Stainless Steel Construction
- High Strength-to-Weight Ratio: Enables thinner struts without sacrificing radial force, ensuring ease of deliverability and vessel conformability.
- Proven Biocompatibility: Stainless steel has a long history of safe use in coronary interventions, supporting stable endothelization.
Laser-Cut Stent Design
- Optimized Strut Geometry: Precisely formed lattice structure provides consistent drug distribution and minimal tissue trauma.
- Improved Crossability: The low-profile SS stent tracks smoothly through complex or calcified lesions, reducing the need for extensive lesion preparation.
Sirolimus Drug Coating (1 µg/mm²)
- Targeted Antiproliferation: Gradual drug release inhibits smooth muscle cell proliferation, a primary contributor to in-stent restenosis.
- Enhanced Endothelialization: Balanced drug elution fosters early endothelial coverage, mitigating late stent thrombosis risk.
Pt-Ir Radiopaque Markers
- Fluoroscopic Precision: Platinum-iridium markers at the stent’s extremities promote accurate stent positioning in the coronary vasculature.
- Reduced Geographic Miss: Clear visibility assists operators in precise stent deployment and lesion coverage.
High-Pressure Endurance
Nominal pressure of 10 atm and a rated burst pressure of 20 atm provide interventional cardiologists the latitude to optimize stent expansion and device apposition based on lesion morphology.
Allgemeine Produktspezifikationen
Spezifikation | Detail / Wert |
Produktname | Atlas Coronary Stent (Stainless Steel) |
Stent Type | Balloon-Expandable Coronary Stent |
Material | 316L Stainless Steel (Medical Grade) |
Strut Thickness | ~100 μm (typical) |
Gestaltung | Open-Cell or Hybrid-Cell design (varies by specific model) |
Nominal Pressure (NP) | ~8–9 atm |
Rated Burst Pressure (RBP) | ~14–16 atm |
Lieferungssystem | Rapid-Exchange (RX) or Over-the-Wire (OTW), typically 140 cm shaft length |
Kompatibilität der Führungsdrähte | 0.014” |
Indikationen | Coronary artery lesion scaffolding (may be used as BMS or platform for DES coating) |
Kontraindikationen | Lesions unsuitable for balloon-expandable stent, severely calcified vessels, left main disease if unprotected, etc. |
Sterilität | Steril (Ethylenoxid) |
Einmaliger Gebrauch | Ja |
Haltbarkeitsdauer | 2–3 years (based on final packaging and coating, if any) |
Betriebstemperatur | Recommended 15–25 °C for storage |
Detaillierte größenabhängige Bestellung & Produktcodes
Stent-Durchmesser (mm) | Stent Länge (mm) | Nominal Pressure (atm) | RBP (atm) | Produkt-Code |
2.00 | 8 | 8 | 14 | ATLS-SS-2.00x08 |
2.00 | 12 | 8 | 14 | ATLS-SS-2.00x12 |
2.00 | 15 | 8 | 14 | ATLS-SS-2.00x15 |
2.00 | 18 | 9 | 16 | ATLS-SS-2.00x18 |
2.00 | 24 | 9 | 16 | ATLS-SS-2.00x24 |
2.00 | 28 | 9 | 16 | ATLS-SS-2.00x28 |
2.00 | 32 | 9 | 16 | ATLS-SS-2.00x32 |
2.00 | 38 | 9 | 16 | ATLS-SS-2.00x38 |
2.25 | 8 | 8 | 14 | ATLS-SS-2.25x08 |
2.25 | 12 | 8 | 14 | ATLS-SS-2.25x12 |
2.25 | 15 | 8 | 14 | ATLS-SS-2.25x15 |
2.25 | 18 | 9 | 16 | ATLS-SS-2.25x18 |
2.25 | 24 | 9 | 16 | ATLS-SS-2.25x24 |
2.25 | 28 | 9 | 16 | ATLS-SS-2.25x28 |
2.25 | 32 | 9 | 16 | ATLS-SS-2.25x32 |
2.25 | 38 | 9 | 16 | ATLS-SS-2.25x38 |
2.50 | 8 | 8 | 14 | ATLS-SS-2.50x08 |
2.50 | 12 | 8 | 14 | ATLS-SS-2.50x12 |
2.50 | 15 | 8 | 14 | ATLS-SS-2.50x15 |
2.50 | 18 | 9 | 16 | ATLS-SS-2.50x18 |
2.50 | 24 | 9 | 16 | ATLS-SS-2.50x24 |
2.50 | 28 | 9 | 16 | ATLS-SS-2.50x28 |
2.50 | 32 | 9 | 16 | ATLS-SS-2.50x32 |
2.50 | 38 | 9 | 16 | ATLS-SS-2.50x38 |
2.75 | 8 | 8 | 14 | ATLS-SS-2.75x08 |
2.75 | 12 | 8 | 14 | ATLS-SS-2.75x12 |
2.75 | 15 | 8 | 14 | ATLS-SS-2.75x15 |
2.75 | 18 | 9 | 16 | ATLS-SS-2.75x18 |
2.75 | 24 | 9 | 16 | ATLS-SS-2.75x24 |
2.75 | 28 | 9 | 16 | ATLS-SS-2.75x28 |
2.75 | 32 | 9 | 16 | ATLS-SS-2.75x32 |
2.75 | 38 | 9 | 16 | ATLS-SS-2.75x38 |
3.00 | 8 | 8 | 14 | ATLS-SS-3.00x08 |
3.00 | 12 | 8 | 14 | ATLS-SS-3.00x12 |
3.00 | 15 | 8 | 14 | ATLS-SS-3.00x15 |
3.00 | 18 | 9 | 16 | ATLS-SS-3.00x18 |
3.00 | 24 | 9 | 16 | ATLS-SS-3.00x24 |
3.00 | 28 | 9 | 16 | ATLS-SS-3.00x28 |
3.00 | 32 | 9 | 16 | ATLS-SS-3.00x32 |
3.00 | 38 | 9 | 16 | ATLS-SS-3.00x38 |
3.50 | 8 | 8 | 14 | ATLS-SS-3.50x08 |
3.50 | 12 | 8 | 14 | ATLS-SS-3.50x12 |
3.50 | 15 | 8 | 14 | ATLS-SS-3.50x15 |
3.50 | 18 | 9 | 16 | ATLS-SS-3.50x18 |
3.50 | 24 | 9 | 16 | ATLS-SS-3.50x24 |
3.50 | 28 | 9 | 16 | ATLS-SS-3.50x28 |
3.50 | 32 | 9 | 16 | ATLS-SS-3.50x32 |
3.50 | 38 | 9 | 16 | ATLS-SS-3.50x38 |
4.00 | 8 | 8 | 14 | ATLS-SS-4.00x08 |
4.00 | 12 | 8 | 14 | ATLS-SS-4.00x12 |
4.00 | 15 | 8 | 14 | ATLS-SS-4.00x15 |
4.00 | 18 | 9 | 16 | ATLS-SS-4.00x18 |
4.00 | 24 | 9 | 16 | ATLS-SS-4.00x24 |
4.00 | 28 | 9 | 16 | ATLS-SS-4.00x28 |
4.00 | 32 | 9 | 16 | ATLS-SS-4.00x32 |
4.00 | 38 | 9 | 16 | ATLS-SS-4.00x38 |
Ähnliche Produkte
-
Stena Mehrschichtiger Durchflussmodulator für Peripheriegeräte
WeiterlesenStrömungsumlenkung Stent für Peripheriegeräte Arterien, Umverteilung von laminar Der Fluss wird von den erkrankten Gefäßsegmenten abgeleitet, was den Erhalt von Aneurysmen oder Seitenästen unterstützt.
-
InWIRE PTCA-Führungsdrähte
WeiterlesenEine Reihe von Hochleistungsfähig Angebot an Koronar-Führungsdrähten dauerhaft Nitinol oder rostfrei Kerne, hydrophile Beschichtungen und verschiedene Spitzenformen für die Kreuzung verkalkt oder komplex Koronarläsionen.
-
Hero Mechanisches Bleientfernungs-System
WeiterlesenA mechanisch alternative for lead extraction, employing specialized locking stylets or sheaths to dislodge fibrotic attachments, ensuring steady traction for safe removal.
-
Extender Medikamentenbeschichteter PTCA-Ballonkatheter Paclitaxel
WeiterlesenA Paclitaxel-beschichtet Koronarer Ballonkatheter zur Verringerung der Restenose bei der perkutanen transluminalen Koronarangioplastie (PTCA), um eine effektive Medikamentenabgabe an die Gefäßwand zu gewährleisten.